Application of the Ag/AgCl chloride sensor in concrete
Source abstract
Abstract
Try to use the Ag/AgCl chloride ion sensor in concrete to test the feasibility of the sensor using in concrete.The long stability of the sensors in concrete specimens was examined,the line response equation of the sensors in concrete was established and was checked through accelerated chloride ion penetration.The results showed that the sensor can work effectively in concrete specimens,the potential drift of the sensor was less than 25mV in concrete specimens within 85d,the repeatability of the sensor was good;the calculation results by the equation were agree to the testing results,the equation was suitable to concrete structure and was accurate.By the equation the Ag/AgCl chloride ion sensor can meet the request of monitoring and detecting the chloride concentration in concrete and realize the aim of warming before the rebar attend to corrosion.