journal article·2017-05-25Open access

Enhanced Osseointegration of a Modified Titanium Implant with Bound Phospho-Threonine: A Preliminary In Vivo Study

Yohei Okazaki, Kazuya Doi, Yoshifumi Oki, Reiko Kobatake, Yasuhiko Abe, Kazuhiro Tsuga

Abstract

Implant surface topography is a key factor in achieving osseointegration. l-Threonine can be chemically and stably bonded to titanium surfaces by phosphorylation. This study investigated the degree of in vivo osseointegration of an implant with a novel o-phospho-l-threonine (p-Thr)-binding surface. MC3T3-E1 cells were seeded on the p-Thr binding surface and machined surface disks, and initial cell attachment was evaluated. p-Thr-binding and machined surface implants were tested in vivo by implantation into the femurs of three male New Zealand white rabbits, and the osseointegration was assessed by measurement of removal torque (RT) and bone-implant contact (BIC) ratio. Initial cell attachment was greater for the p-Thr-binding than for the machined surface implant group (P < 0.05). In addition, RT and BIC values were higher for the p-Thr-binding surface than for the machined surface (P < 0.05). These results indicate that our implant with a p-Thr-binding surface can achieve enhanced osseointegration.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Advanced Prosthodontics, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi, Minami-ku, Hiroshima 734-8553, Japan

References (23)

Show source-provided references
1. Experimental studies on oxidezed implants. A histomorphometrical and biomechanical analysis
2. Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis—A review10.1016/j.actbio.2013.10.036 ↗
3. Implant surface characteristics modulate differentiation behavior of cells in the osteoblastic lineage10.1177/08959374990130011301 ↗
4. Oral implant surfaces: Part 1—Review focusing on topographic and chemical properties of different surfaces and in vivo responses to them
5. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
6. Effects of implant surface microtopography on osteoblast gene expression10.1111/j.1600-0501.2005.01170.x ↗
7. Osteoblast-like cells are sensitive to submicron-scale surface structure10.1111/j.1600-0501.2005.01195.x ↗
8. Acidic and basic properties of hydroxylated metal oxide surfaces10.1039/df9715200264 ↗
9. Influence of implant surface topography on primary stability in a standardized osteoporosis rabbit model study10.3390/jfb6010143 ↗
10. Biological factors contributing to failures of osseointegrated oral implants, (II). Etiopathogenesis10.1046/j.0909-8836..t01-6-.x ↗
11. Biofilm on dental implants: A review of the literature
12. New surface modification of titanium implant with phospho-amino acid10.4012/dmj.24.536 ↗
13. Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative clinical study using resonance frequency analysis
14. Spontaneous progression of experimental peri-implantitis at implants with different surface characteristics: an experimental study in dogs10.1111/j.1600-051X.2011.01820.x ↗
15. In vivo study of the initial bacterial adhesion on different implant materials10.1016/j.archoralbio.2013.04.011 ↗
16. The mechanisms of passive dissolution of titanium in a model physiological environment10.1002/jbm.820260305 ↗
17. Osteoblast culture on polished titanium disks modified with phosphonic acids10.1002/jbm.10205 ↗
18. Osseointegration and the edentulous predicament. The 10-year-old Toronto study10.1038/sj.bdj.4807583 ↗
19. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis10.1034/j.1600-0501.1996.070308.x ↗
20. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study10.1016/S0901-5027(99)80156-8 ↗
21. Assessing the implant/bone interface by using natural frequency analysis10.1067/moe.2000.108918 ↗
22. Influence on early osseointegration of dental implants installed with two different drilling protocols: A histomorphometric study in rabbit10.1111/j.1600-0501.2010.02009.x ↗
23. Removal torques for polished and rough titanium implants