journal article·2022-05-17Open access

Restoration in Vertebral Compression Fractures (VCF): Effectiveness Evaluation Based on 3D Technology

David C. Noriega González, Francisco Ardura Aragón, Jesús Crespo Sanjuan, Silvia Santiago Maniega, Gregorio Labrador Hernández, María Bragado González, Daniel Pérez-Valdecantos, Alberto Caballero-García, Alfredo Córdova

Abstract

There are few studies about anatomical reduction of the fractured vertebral body before stabilization for treatment of vertebral compression fracture (VCF). Although restoration on vertebral height has been useful, the reduction of fractured endplates is limited. The vertebra is part of a joint, and vertebral endplates must be treated like other weight-bearing joint to avoid complications. The aim of this study was to evaluate the feasibility of anatomic reduction of vertebral compression fracture, in different bone conditions, fracture types, and ages (VCF). Under methodological point of view, we followed different steps: first was the placement of two expandable titanium implants just below the fracture. Later, to push the fractured endplates into a more anatomical position, the implants were expanded. Finally, with the implants perfectly positioned, PMMA cement was injected to avoid any loss of correction. To evaluate the effectiveness of this procedure in anatomical fracture reduction, a method based on 3D CT reconstructions was developed. In this paper, we have developed the procedure in three case studies. In all of them, we were able to demonstrate the efficacy of this procedure to reduce the VCF. The percentage of correction of the kyphotic angle varied range between 49% and 62% with respect to the value after the fracture preoperative value. This was accompanied by a reduction of the pain level on the VAS scale around 50%. In conclusion, this novel approach to the vertebral fracture treatment (VCF) associated with 3D assessment have demonstrated the possibility of reducing the vertebral kyphosis angle and the vertebral endplate fractures. However, given the few cases presented, more studies are necessaries to confirm these results.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Surgery, Ophthalmology, Otorhinolaryngology and Physiotherapy, Faculty of Medicine, University of Valladolid, 47005 Valladolid, Spain

Department of Orthopedic, Clinic University Hospital of Valladolid, 47005 Valladolid, Spain

Department of Biochemistry, Molecular Biology and Physiology, Health Sciences Faculty, GIR: “Physical Exercise and Aging”, University of Valladolid, Campus Universitario “Los Pajaritos”, 42004 Soria, Spain

Department of Anatomy and Radiology, Health Sciences Faculty, GIR: “Physical Exercise and Aging”, University of Valladolid, Campus Universitario “Los Pajaritos”, 42004 Soria, Spain

Funding

Caja Rural de Soria

References (55)

Show source-provided references
1. Vertebroplasty and Kyphoplasty: A Systematic Review of 69. Clinical Studies10.1097/01.brs.0000229254.89952.6b ↗
2. Incidence and economic burden of osteoporosis-related farctures in the United States, 2005–202510.1359/jbmr.061113 ↗
3. Osteoporotic compression fractures of the spine; current options and considerations for treatment10.1016/j.spinee.2006.04.013 ↗
4. Reduced pulmonary function in patients with spinal osteoporosic fractures10.1007/s001980050063 ↗
5. The clinical consequences of vertebral compression fracture10.1016/8756-3282(92)90193-Z ↗
6. A case-control study of quality of life and functional impairment in women with long-standing vertebral osteoporotic fracture10.1007/s001980050178 ↗
7. Changes of pulmonary function for patients with osteoporotic vertebral compression fractures after kyphoplasty10.1097/01.bsd.0000211273.74238.0e ↗
8. Post-traumatic kyphosis. A review of forty-eight surgically treated patients10.2106/00004623-198163060-00005 ↗
9. Does spinal kyphotic deformity influence the biomechanical characteristics of the adjacent motion segments? An in vivo animal model10.1097/00007632-199910150-00014 ↗
10. Traumatic kyphosis of the thoracolumbar spine
11. Vertebral compression fractures10.12968/hmed.2018.79.1.36 ↗
12. Does vertebral height restoration achieved at vertebroplasty matter?10.1097/01.RVI.0000163014.71889.16 ↗
13. The dynamic mobility of vertebral compression fractures10.1359/jbmr.2003.18.1.24 ↗
14. Influence of age and gender on thoracic vertebral body shape and disc degeneration: An MR investigation of 169 cases10.1046/j.1469-7580.2000.19740647.x ↗
15. Lumbar disc degeneration: Correlation with age, sex, and spine level in 600 autopsy specimens10.1097/00007632-198802000-00008 ↗
16. Internal pressure measurements during burst fracture formation in human lumbar vertebrae10.1097/00007632-200206010-00005 ↗
17. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
18. Calling all vertebral fractures classification of vertebral compression fractures: A consensus for comparison of treatment and outcome10.1359/jbmr.2002.17.2.185 ↗
19. The reduction of endplate fractures during balloon vertebroplasty: A detailed radiological analysis of the treatment of burst fractures using pedicle screws, balloon vertebroplasty, and calcium phosphate cement10.1097/01.brs.0000173895.19334.e2 ↗
20. Functional outcomes of kyphoplasty for the treatment of osteoporotic and osteolytic vertebral compression fractures10.1007/s00198-006-0068-3 ↗
21. Clinical outcomes after acute osteoporotic vertebral fractures: A 2-year non-randomised trial comparing percutaneous vertebroplasty with conservative therapy10.5694/j.1326-5377.2006.tb00148.x ↗
22. Comparison of vertebroplasty and balloon kyphoplasty for treatment of vertebral compression fractures: A meta-analysis of the literature10.1016/j.spinee.2007.04.004 ↗
23. Kyphoplasty treatment of vertebral fractures: 2-year outcomes show sustained benefits10.1097/01.brs.0000192687.07392.f1 ↗
24. Percutaneous vertebroplasty: Functional improvement in patients with osteoporotic compression fractures10.1097/01.brs.0000216487.97965.38 ↗
25. Treatment of painful osteoporotic or traumatic vertebral compression fractures by percutaneous vertebral augmentation procedures: A nonrandomized comparison between vertebroplasty and kyphoplasty10.1097/AJP.0b013e31805593be ↗
26. Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): A randomised controlled trial10.1016/S0140-6736(09)60010-6 ↗
27. Functional radiographs of acute thoracolumbar burst fractures. A biomechanical study10.1097/00007632-199312000-00011 ↗
28. Kyphosis recurrence after posterior short-segment fixation in thoracolumbar burst fractures10.3171/SPI/2008/8/3/246 ↗
29. Evaluation of pulmonary function and quality of life in women with osteoporosis10.1007/s00198-005-1834-3 ↗
30. Risk of mortality following clinical fractures10.1007/s001980070075 ↗
31. Mortality after all major types of osteoporotic fracture in men and women: An observational study10.1016/S0140-6736(98)09075-8 ↗
32. The Vertebral Fracture Cascade: Etiology and Clinical Implications10.1016/j.jocd.2015.08.007 ↗
33. Mortality risk associated with low-trauma osteoporotic fracture and subsequent fracture in men and women10.1001/jama.2009.50 ↗
34. A clinical profile of back pain and disability in patients with spinal osteoporosis10.1016/8756-3282(94)90887-7 ↗
35. Urinary tract infections in the potential vertebroplasty patient: Incidence, significance, and management10.3174/ajnr.A1385 ↗
36. A New 3D Reconstruction Method to Assess Anatomical Restoration in Vertebral Compression Fractures
37. Measurement of vertebral area on spine X-rays in osteoporosis: Reliability of digitizing techniques10.1002/jbmr.5650050707 ↗
38. Morphometric evaluations of personalised 3D reconstructions and geometric models of the human spine10.1007/BF02510968 ↗
39. Quantitative evaluation of acquisition parameters in three-dimensional imaging with multidetector computed tomography using human skull phantom10.1007/s10278-002-5054-5 ↗
40. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning10.1007/s00256-007-0386-3 ↗
41. Posterior instrumentation for thoracolumbar fractures10.5435/00124635-200411000-00007 ↗
42. Respective contributions of vertebroplasty and kyphoplasty to the management of osteoporotic vertebral fractures10.1016/j.jbspin.2006.09.004 ↗
43. Balloon Kyphoplasty Is a Safe and Effective Option for the Treatment of Vertebral Compression Fractures in Solid-Organ Transplant Recipients10.6002/ect.2016.0035 ↗
44. Comparison of Percutaneous Vertebroplasty and Balloon Kyphoplasty for the Treatment of Single Level Vertebral Compression Fractures: A Meta-analysis of the Literature
45. Balloon kyphoplasty and vertebroplasty for vertebral compression fractures: A comparative systematic review of efficacy and safety10.1097/01.brs.0000244639.71656.7d ↗
46. Editorial: Treatment of fractures of the calcaneus10.1302/0301-620X.57B4.411 ↗
47. White, A.A., and Panjabi, M.M. (1990). Clinical Biomechanics of the Spine, Lippincott. [2nd ed.].
48. Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty10.1007/s00586-005-0018-3 ↗
49. Posture Stability and Kinematics While Performing a 180° Turning Step in Elderly Individuals with and Without Vertebral Compression Fracture and in Middle-Aged Adults10.1007/s40846-020-00508-9 ↗
50. Finite Element Investigation of Fracture Risk Under Postero-Anterior Mobilization on a Lumbar Bone in Elderly with and Without Osteoporosis10.1007/s40846-021-00607-1 ↗
51. Comparison of Osseointegration in Different Intravertebral Fixators
52. Codrea, C.I., Croitoru, A.M., Baciu, C.C., Melinescu, A., Ficai, D., Fruth, V., and Ficai, A. (2021). Advances in Osteoporotic Bone Tissue Engineering. J. Clin. Med., 10.10.3390/jcm10020253 ↗
53. Effect of Chemistry on Osteogenesis and Angiogenesis Towards Bone Tissue Engineering Using 3D Printed Scaffolds10.1007/s10439-016-1646-y ↗
54. An effective self-powered strategy to endow titanium implant surface with associated activity of anti-biofilm and osteogenesis10.1016/j.nanoen.2020.105201 ↗
55. A strawberry-like Ag-decorated barium titanate enhances piezoelectric and antibacterial activities of polymer scaffold10.1016/j.nanoen.2020.104825 ↗