journal article·2023-07-12Open access

Adhesion and Surface Roughness of Apatite-Containing Carbomer and Improved Ionically Bioactive Resin Compared to Glass Ionomers

Handan Yıldırım Işık, Aylin Çilingir

Abstract

The surface roughness of different glass–ionomer-based materials and their shear bond strength with a resin composite with and without thermal cycling were evaluated. Ketac Molar (KM, 3M ESPE, St. Paul, MN, USA), Glass Carbomer (GC, GCP Dental, Leiden, The Netherlands), Bioactive (BA, PULPDENT, Corporation, Watertown, MA, USA) and Fuji II LC (FJ, GC, Tokyo, Japan) were used to prepare the specimens and they were kept in distilled water at 37 °C for 24 h. The surface roughness of the specimens was measured with a profilometer (n = 6). A universal adhesive resin was applied on glass–ionomer materials and cylindrical universal composites were applied and polymerized, respectively (n = 16). The specimens were divided into two subgroups. The first subgroup was subjected to thermal cycling. Shear bond strength was investigated for both subgroups (n = 8). Stereomicroscopy and SEM examinations were performed. The roughest surface was obtained in the GC group (p < 0.05). The shear bond strength of the specimens without thermal cycling was higher than that of those with thermal cycling (p < 0.05). The lowest shear bond was measured in the GC group (p < 0.05). Although FJ, KM and BA have been observed to be suitable materials for clinical use, BA, in particular, is evidenced to become the best option among the materials we tested. GC cement’s long-term performance needs to be improved.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Restorative Dentistry, Faculty of Dentistry, Beykent University, 34500 İstanbul, Turkey

Department of Restorative Dentistry, Faculty of Dentistry, Trakya University, Balkan Campus, 22030 Edirne, Turkey

Funding

Scientific Research Projects Coordination Unit of Trakya University

References (44)

Show source-provided references
1. Recent Approaches in Restorative Glass Ionomer Cements
2. Evaluation of Restorative Materials Containing Preventive Additives in a Secondary Caries Model in Vitro10.1159/000496401 ↗
3. Noncarious Cervical Lesions: Morphology and Progression, Prevalence, Etiology, Pathophysiology Clinical Guidelines for Restoration10.1111/jopr.13585 ↗
4. Selection of Dental Materials and Longevity of Replaced Restorations in Public Dental Health Clinics in Northern Sweden10.1016/j.jdent.2009.04.010 ↗
5. Distribution and Excretion of BisGMA in Guinea Pigs10.1177/154405910808700401 ↗
6. Vasiliu, S., Racovita, S., Gugoasa, I.A., Lungan, M.A., Popa, M., and Desbrieres, J. (2021). The Benefits of Smart Nanoparticles in Dental Applications. Int. J. Mol. Sci., 22.10.3390/ijms22052585 ↗
7. Effect of Different Thermo-Light Polymerization on Flexural Strength of Two Glass Ionomer Cements and a Glass Carbomer Cement10.1016/j.prosdent.2016.09.019 ↗
8. Influence of Thermo-Light Curing with Dental Light-Curing Units on the Microhardness of Glass-Ionomer Cements10.11607/prd.2405 ↗
9. Effect of Chemical and Mechanical Degradation on Surface Roughness of Three Glass Ionomers and a Nanofilled Resin Composite10.2341/10-406-L ↗
10. Effect of Gloss and Heat on the Mechanical Behaviour of a Glass Carbomer Cement10.1016/j.jdent.2012.11.005 ↗
11. Effects of Incorporation of Nano-Fluorapatite Particles on Microhardness, Fluoride Releasing Properties, and Biocompatibility of a Conventional Glass Ionomer Cement (GIC)10.4012/dmj.2015-437 ↗
12. Surface Roughness of Glass Ionomer Cements Indicated for Uncooperative Patients According to Surface Protection Treatment
13. Najeeb, S., Khurshid, Z., Zafar, M.S., Khan, A.S., Zohaib, S., Martí, J.M.N., Sauro, S., Matinlinna, J.P., and Rehman, I.U. (2016). Modifications in Glass Ionomer Cements: Nano-Sized Fillers and Bioactive Nanoceramics. Int. J. Mol. Sci., 17.10.3390/ijms17071134 ↗
14. Effect of Acid Etching of Glass Ionomer Cement Surface on the Microleakage of Sandwich Restorations10.1590/S1678-77572007000300014 ↗
15. Bilgrami, A., Maqsood, A., Alam, M.K., Ahmed, N., Mustafa, M., Alqahtani, A.R., Alshehri, A., Alqahtani, A.A., and Alghannam, S. (2022). Evaluation of Shear Bond Strength between Resin Composites and Conventional Glass Ionomer Cement in Class II Restorative Technique—An In Vitro Study. Materials, 15.10.3390/ma15124293 ↗
16. Evaluation of Surface Characteristics of Dental Composites Using Profilometry, Scanning Electron, Atomic Force Microscopy and Gloss-Meter10.1007/s10856-006-0675-8 ↗
17. Lardani, L., Derchi, G., Marchio, V., and Carli, E. (2022). One-Year Clinical Performance of ActivaTM Bioactive-Restorative Composite in Primary Molars. Children, 9.10.3390/children9030433 ↗
18. Beresescu, L., Kovacs, M., Vlasa, A., Stoica, A.M., Benedek, C., Pop, M., Bungardean, D., and Eșian, D. (2022). Retention Ability of a Glass Carbomer Pit and Fissure Sealant. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph19041966 ↗
19. Shear Bond Strength and Interface Analysis between a Resin Composite and a Recent High-Viscous Glass Ionomer Cement Bonded with Various Adhesive Systems10.1007/s00784-018-2678-5 ↗
20. In Vitro Embryotoxicity Assessment with Dental Restorative Materials10.1016/j.jdent.2004.08.001 ↗
21. The Biocompatibility of Resin-Modified Glass-Ionomer Cements for Dentistry10.1016/j.dental.2008.04.005 ↗
22. Chrószcz-Porębska, M.W., Barszczewska-Rybarek, I.M., Kazek-Kęsik, A., and Ślęzak-Prochazka, I. (2023). Cytotoxicity and Microbiological Properties of Copolymers Comprising Quaternary Ammonium Urethane-Dimethacrylates with Bisphenol A Glycerolate Dimethacrylate and Triethylene Glycol Dimethacrylate. Materials, 16.10.3390/ma16103855 ↗
23. Bond Strengths of Silorane- and Methacrylate-Based Composites to Various Underlying Materials10.1155/2014/782090 ↗
24. Effect of Cavity Lining on the Restoration of Root Surface Carious Lesions: A Split-Mouth, 5-Year Randomized Controlled Clinical Trial10.1007/s00784-019-03001-z ↗
25. Microleakage Evaluation of Expired and Non-Expired Resin Composites and Bonding Agents: In Vitro Study10.1177/23202068221079205 ↗
26. Microleakage Testing
27. Effect of Conditioners on Bond Durability of Resin Composite to Nd:YAP Laser-Irradiated Dentin10.4012/dmj.25.463 ↗
28. Hanson, M.S., Ontiveros, J.C., English, J.D., Wirthlin, J.O., Cozad, B.E., Harrington, D.A., and Kasper, F.K. (2023). Effect of Material and Pad Abrasion on Shear Bond Strength of 3D-Printed Orthodontic Brackets. Orthod. Craniofac. Res., Online ahead of print.10.1111/ocr.12667 ↗
29. Effect of Adhesive Systems Associated with Resin-Modified Glass Ionomer Cements10.1111/j.1365-2842.2006.01536.x ↗
30. Influence of Chisel Width on Shear Bond Strength of Composite to Enamel Influência Da Largura Do Cinzel Sobre a Resistência Ao Cisalhamento Da União Esmalte/Resina Composta
31. Cam Iyonomer Içerikli Farklı Restoratif Materyallerin Yüzey Pürüzlülüklerinin Değerlendirilmesi
32. Cam Iyonomer Içerikli Dört Farklı Restoratif Materyalin Yüzey Pürüzlülüklerinin Değerlendirilmesi
33. Effect of Surface Roughness on Stain Resistance of Dental Resin Composites10.1111/j.1708-8240.2005.tb00094.x ↗
34. Porosity and Pore Size Distribution in High-Viscosity and Conventional Glass Ionomer Cements: A Micro-Computed Tomography Study10.5395/rde.2021.46.e57 ↗
35. Mechanical Properties and Microstructures of Glass-Ionomer Cements10.1016/S0109-5641(99)00093-7 ↗
36. Surface Roughness of Enamel and Four Resin Composites
37. Effect of Two Different Polishing Systems on Fluoride Release, Surface Roughness and Bacterial Adhesion of Newly Developed Restorative Materials10.1111/jerd.12313 ↗
38. Effect of Total-Etch and Self-Etch Adhesives on the Bond Strength of Composite to Glass-Ionomer Cement/Resin-Modified Glass-Ionomer Cement in the Sandwich Technique—A Systematic Review10.4103/1735-3327.326645 ↗
39. Comparison of Shear Bond Strength of Aesthetic Restorative Materials10.4103/0976-237X.94541 ↗
40. Üç Farklı Hibrit Kompozit Rezinin Iki Hibrit Iyonomer ve Bir Konvansiyonel Cam-Iyonomer Simana Bağlanma Güçlerinin Değerlendirilmesi
41. Comparative Evaluation of Shear Bond Strength of Various Glass Ionomer Cements to Dentin of Primary Teeth: An in Vitro Study10.5005/jp-journals-10005-1362 ↗
42. The Effect of Thermal Cycling on the Bovine Dentine Shear Bond Strength of Current Adhesive Systems10.1111/j.1365-2842.2004.01318.x ↗
43. Meta-Analytical Review of Factors Involved in Dentin Adherence10.1177/00220345010800070301 ↗
44. Effect of Bonding Application Time on Bond Strength of Composite Resin to Glass Ionomer Cement