Effect of the Abutment Rigidity on the Wear Resistance of a Lithium Disilicate Glass Ceramic: An In Vitro Study
Source abstract
Abstract
Lithium disilicate (LDS) glass ceramics are among the most common biomaterials in conservative dentistry and prosthodontics, and their wear behavior is of paramount clinical interest. An innovative in vitro model is presented, which employs CAD/CAM technology to simulate the periodontal ligament and alveolar bone. The model aims to evaluate the effect of the abutment rigidity on the wear resistance of the LDS glass ceramic. Two experimental groups (LDS restorations supported by dental implants, named LDS-on-Implant, or by hybrid ceramic tooth replicas with artificial periodontal ligament, named LDS-on-Tooth-Replica) and a control group (LDS-Cylinders) were compared. Fifteen samples (n = 15) were fabricated for each group and subjected to testing, with LDS antagonistic cusps opposing them over 120,000 cycles using a dual axis chewing simulator. Wear resistance was analyzed by measuring the vertical wear depth (mm) and the volume loss (mm3) on each LDS sample, as well as the linear antagonist wear (mm) on LDS cusps. Mean values were calculated for LDS-Cylinders (0.186 mm, 0.322 mm3, 0.220 mm, respectively), LDS-on-Implant (0.128 mm, 0.166 mm3, 0.199 mm, respectively), and LDS-on-Tooth-Replica (0.098 mm, 0.107 mm3, 0.172 mm, respectively) and compared using one-way-ANOVA and Tukey’s tests. The level of significance was set at 0.05 in all tests. Wear facets were inspected under a scanning electron microscope. Data analysis revealed that abutment rigidity was able to significantly affect the wear pattern of LDS, which seems to be more intense on rigid implant-abutment supports compared to resilient teeth replicas with artificial periodontal ligament.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced ceramic materials synthesis · Glass properties and applications · Recycling and utilization of industrial and municipal waste in materials production
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Private Practice, 01650 Warsaw, Poland
Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy
Department of Innovative Technologies in Medicine & Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy
Department of Conservative Dentistry, Medical University of Warsaw, 02091 Warsaw, Poland
References (75)
Show source-provided references
1. Branco, A.C., Colaço, R., Figueiredo-Pina, C.G., and Serro, A.P. (2020). A State-of-the-Art Review on the Wear of the Occlusal Surfaces of Natural Teeth and Prosthetic Crowns. Materials, 13.10.3390/ma13163525 ↗
2. Twenty-four months in vivo wear of enamel antagonists to lithium disilicate implant crowns—A pilot study10.1016/j.jdent.2022.104215 ↗
3. Quantitative in vivo wear of human enamel10.1177/00220345890680120601 ↗
4. Chapter 9: Acidic Beverages and Foods Associated with Dental Erosion and Erosive Tooth Wear10.1159/000455376 ↗
5. Nota, A., Pittari, L., Paggi, M., Abati, S., and Tecco, S. (2022). Correlation between Bruxism and Gastroesophageal Reflux Disorder and Their Effects on Tooth Wear. A Systematic Review. J. Clin. Med., 11.10.3390/jcm11041107 ↗
6. Etiology and pathogenesis of dental erosion
7. Wear of dental materials: Clinical significance and laboratory wear simulation methods —A review10.4012/dmj.2018-140 ↗
8. Prevalence and association of gastroesophageal reflux disease and dental erosion: An overview of reviews10.1016/j.jdent.2023.104520 ↗
9. Inchingolo, A.M., Malcangi, G., Ferrante, L., Del Vecchio, G., Viapiano, F., Mancini, A., Inchingolo, F., Inchingolo, A.D., Di Venere, D., and Dipalma, G. (2023). Damage from Carbonated Soft Drinks on Enamel: A Systematic Review. Nutrients, 15.10.3390/nu15071785 ↗
10. Oudkerk, J., Grenade, C., Davarpanah, A., Vanheusden, A., Vandenput, S., and Mainjot, A.K. (J. Oral. Rehabil., 2023). Risk Factors of Tooth Wear in Permanent Dentition: A Scoping Review, J. Oral. Rehabil., epub ahead of print.10.1111/joor.13489 ↗
11. Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool10.1016/j.heliyon.2022.e12103 ↗
12. Intra-oral restorative materials wear: Rethinking the current approaches: How to measure wear10.1016/j.dental.2006.02.003 ↗
13. Lithium disilicate posterior overlays: Clinical and biomechanical features10.1007/s00784-019-02972-3 ↗
14. A guide to managing tooth wear: The Radboud philosophy10.1038/sj.bdj.2018.164 ↗
15. Canal shaping of different single-file systems in curved root canals10.1016/j.jds.2017.03.001 ↗
16. Bond strength evaluation of three self-adhesive luting systems used for cementing composite and porcelain10.2341/10-205-L ↗
17. Meta-analytical analysis on components released from resin-based dental materials10.1007/s00784-022-04625-4 ↗
18. Shear bond strength of glass ionomer and resin-based cements to different types of zirconia10.1111/jerd.12638 ↗
19. Wear Properties of Different Additive Restorative Materials Used for Onlay/Overlay Posterior Restorations10.2341/19-115-L ↗
20. Safe clinical technique for increasing the occlusal vertical dimension in case of erosive wear and missing teeth10.1002/ccr3.4747 ↗
21. Effetto della mordenzatura con acido fluoridrico su flessione e adesione del disilicato di litio10.19256/d.cadmos.07.2019.06 ↗
22. Differences in the biomechanical behaviors of natural teeth and dental implants10.1016/j.dental.2021.01.003 ↗
23. Mechanical complications of dental implants10.1034/j.1600-0501.2000.011S1156.x ↗
24. Comparative study of mechanical properties of dental restorative materials and dental hard tissues in compressive loads10.1177/1758736014555246 ↗
25. Wear properties of dental ceramics and porcelains compared with human enamel10.1016/j.prosdent.2015.09.010 ↗
26. De Angelis, F., Buonvivere, M., Sorrentino, E., Rondoni, G.D., and D’Arcangelo, C. (2022). Wear Properties of Conventional and High-Translucent Zirconia-Based Materials. Materials, 15.10.3390/ma15207324 ↗
27. Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: A systematic review10.1016/j.ijom.2014.10.023 ↗
28. Group 4 ITI Consensus Report: Risks and biologic complications associated with implant dentistry10.1111/clr.13307 ↗
29. Mechanical failures of dental implants and supported prostheses: A systematic review10.1016/j.jobcr.2023.02.009 ↗
30. Lee, S.J., Alamri, O., Cao, H., Wang, Y., Gallucci, G.O., and Lee, J.D. (Clin. Implant. Dent. Relat. Res., 2022). Occlusion as a Predisposing Factor for Peri-Implant Disease: A Review Article, Clin. Implant. Dent. Relat. Res., epub ahead of print.10.1111/cid.13152 ↗
31. Di Fiore, A., Montagner, M., Sivolella, S., Stellini, E., Yilmaz, B., and Brunello, G. (2022). Peri-Implant Bone Loss and Overload: A Systematic Review Focusing on Occlusal Analysis through Digital and Analogic Methods. J. Clin. Med., 11.10.3390/jcm11164812 ↗
32. In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth10.4047/jap.2018.10.4.300 ↗
33. Do sensation differences exist between dental implants and natural teeth?: A meta-analysis10.1111/clr.12271 ↗
34. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)10.1111/j.1600-0501.2007.01439.x ↗
35. Shock absorption capacity of restorative materials for dental implant prostheses: An in vitro study10.11607/ijp.3241 ↗
36. A multicenter randomized controlled clinical pilot study of buccally micro-veneered lithium-disilicate and zirconia crowns supported by titanium base abutments: 1-year outcomes10.1111/clr.14018 ↗
37. Cemented versus screw-retained posterior implant-supported single crowns: A 24-month randomized controlled clinical trial10.1111/clr.13849 ↗
38. Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth10.4047/jap.2020.12.1.1 ↗
39. Implant-supported and tooth-supported single crowns fabricated with lithium-disilicate seem to have a high 10-year survival rate10.1016/j.adaj.2017.02.022 ↗
40. Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses10.1016/j.jdent.2016.10.017 ↗
41. Monolithic lithium-disilicate single crowns supported by zirconia oral implants: Three-year results of a prospective cohort study10.1111/clr.12716 ↗
42. Precision of In Vivo Quantitative Tooth Wear Measurement using Intra-Oral Scans
43. The threshold of an intra oral scanner to measure lesion depth on natural unpolished teeth10.1016/j.dental.2022.06.022 ↗
44. Koletsi, D., Iliadi, A., Eliades, T., and Eliades, G. (2019). In Vitro Simulation and In Vivo Assessment of Tooth Wear: A Meta-Analysis of In Vitro and Clinical Research. Materials, 12.10.3390/ma12213575 ↗
45. Wear measurement of dental tissues and materials in clinical studies: A systematic review10.1016/j.dental.2018.03.002 ↗
46. An evaluation of wear when enamel is opposed by various ceramic materials and gold10.1016/j.prosdent.2006.09.002 ↗
47. Wear Evaluation of Prosthetic Materials Opposing Themselves10.2341/16-212-L ↗
48. Tooth Mobility Reproduction in Dental Material Research: A Scoping Review10.2174/1874210602014010465 ↗
49. Mechanical Properties of Elastomeric Impression Materials: An In Vitro Comparison10.1155/2015/428286 ↗
50. Influence of Resilient Support of Abutment Teeth on Fracture Resistance of All-Ceramic Fixed Partial Dentures: An In Vitro Study
51. Micro-CT evaluation of a novel periodontal ligament simulation technique for dental experimental models
52. Fatigue resistance of all-ceramic fixed partial dentures-Fatigue tests and finite element analysis10.1016/j.dental.2017.12.005 ↗
53. Stability of implants and natural teeth as determined by the Periotest over 60 months of function10.1563/1548-1336(2001)027<0198:SOIANT>2.3.CO;2 ↗
54. In-depth morphological evaluation of tooth anatomic lengths with root canal configurations using cone beam computed tomography in North American population10.1590/1678-7757-2019-0103 ↗
55. Comparison of mechanical property and role between enamel and dentin in the human teeth10.1177/1758736014520809 ↗
56. Hardness and indentation modulus of human enamel and dentin10.1002/sia.7187 ↗
57. How to qualify and validate wear simulation devices and methods10.1016/j.dental.2006.02.002 ↗
58. Wear characteristics of polished and glazed lithium disilicate ceramics opposed to three ceramic materials10.2334/josnusd.58.117 ↗
59. Influence of different surface treatments on two-body wear and fracture load of monolithic CAD/CAM ceramics10.1007/s00784-019-03173-8 ↗
60. In Vitro Shock Absorption Tests on Implant-Supported Crowns: Influence of Crown Materials and Luting Agents10.11607/jomi.5463 ↗
61. Wear of dental ceramics10.4322/bds.2023.e3638 ↗
62. How to simulate wear? Overview of existing methods10.1016/j.dental.2006.02.004 ↗
63. Wear of resin denture teeth by two-body contact10.1016/j.dental.2005.03.009 ↗
64. Factors affecting enamel and ceramic wear: A literature review10.1067/mpr.2002.123851 ↗
65. Wear performance of dental ceramics after grinding and polishing treatments10.1016/j.jmbbm.2012.03.002 ↗
66. Influence of full-contour zirconia surface roughness on wear of glass-ceramics10.1111/jopr.12088 ↗
67. Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia10.1016/j.dental.2020.01.015 ↗
68. Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing10.1016/j.jdent.2014.09.008 ↗
69. Wear behavior of human enamel against lithium disilicate glass ceramic and type III gold10.1016/j.prosdent.2014.08.002 ↗
70. Wear performance of substructure ceramics and veneering porcelains10.1016/j.dental.2011.04.001 ↗
71. Appropriateness of viscoelastic soft materials as in vitro simulators of the periodontal ligament10.1111/j.1365-2842.2011.02231.x ↗
72. Structure of periodontal tissues in health and disease10.1111/j.1600-0757.2005.00141.x ↗
73. Determination of Young’s modulus of mandibular bone using inverse analysis10.1016/j.medengphy.2010.03.009 ↗
74. De Angelis, F., Vadini, M., Buonvivere, M., Valerio, A., Di Cosola, M., Piattelli, A., Biferi, V., and D’Arcangelo, C. (2023). In Vitro Mechanical Properties of a Novel Graphene-Reinforced PMMA-Based Dental Restorative Material. Polymers, 15.10.3390/polym15030622 ↗
75. The mechanical properties of human dentin: A critical review and re-evaluation of the dental literature10.1177/154411130301400103 ↗