journal article·2022-11-14Open access

Fracture and Fatigue of Dental Implants Fixtures and Abutments with a Novel Internal Connection Design: An In Vitro Pilot Study Comparing Three Different Dental Implant Systems

Sung-Woon On, Sang-Min Yi, In-Young Park, Soo-Hwan Byun, Byoung-Eun Yang

Abstract

The aim of this study was to compare the mechanical behaviors of three dental implant fixtures with different abutment connection designs. Three implant systems were studied: the control (BLX implant), test group 1 (TORX++ implant), and test group 2 (IU implant). Three samples from each group were subjected to static compression to fracture tests to determine the maximum fracture load, and twelve samples were exposed to fatigue tests that measured how many cycles the implants could endure before deformation or fracture. Detailed images of the implant–abutment assemblies were obtained using micro-computed tomography imaging, and fractured or deformed areas were observed using a scanning electron microscope (SEM). The mean maximum breaking loads of 578.45 ± 42.46 N, 793.26 ± 57.43 N, and 862.30 ± 74.25 N were obtained for the BLX, TORX++, and IU implants, respectively. All samples in the three groups withstood 5 × 106 cycles at 50% of the nominal peak value, and different fracture points were observed. All abutment connection designs showed suitable mechanical properties for intraoral use. Microscopic differences in the fracture patterns may be due to the differences in the fixture design or abutment connection, and mechanical complications could be prevented by lowering the overload reaching the implant or preventing peri-implantitis.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Division of Oral and Maxillofacial Surgery, Department of Dentistry, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong 18450, Korea

Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea

Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea

Division of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14066, Korea

Division of Orthodontics, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14066, Korea

Funding

Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI) · Ministry of Health & Welfare

References (17)

Show source-provided references
1. 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: A retrospective study in 303 partially edentulous patients10.1111/j.1708-8208.2012.00456.x ↗
2. Outcome of oral implant treatment in partially edentulous jaws followed 20 years in clinical function10.1111/j.1708-8208.2006.00019.x ↗
3. Long-term evaluation of Astra Tech and Branemark implants in patients treated with full-arch bridges. Results after 12–15 years10.1111/j.1600-0501.2012.02524.x ↗
4. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years10.1111/j.1600-0501.2012.02546.x ↗
5. A systematic review of the 5-year survival and complication rates of implant-supported single crowns10.1111/j.1600-0501.2007.01453.x ↗
6. What Are the Incidence and Factors Associated With Implant Fracture?10.1016/j.joms.2017.05.014 ↗
7. Effects of different abutment connection designs on the stress distribution around five different implants: A 3-dimensional finite element analysis10.1563/AAID-JOI-D-10-00127 ↗
8. Choi, N.H., Yoon, H.I., Kim, T.H., and Park, E.J. (2019). Improvement in Fatigue Behavior of Dental Implant Fixtures by Changing Internal Connection Design: An In Vitro Pilot Study. Materials, 12.10.3390/ma12193264 ↗
9. (2016). Dentistry—Implants—Dynamic Loading Test for Endosseous Dental Implants (Standard No. ISO 14801:2016 (en)).
10. Effect of loading frequency on cyclic fatigue lifetime of a standard-diameter implant with an internal abutment connection10.1016/j.dental.2018.09.001 ↗
11. Limits of human bite strength10.1016/0022-3913(86)90480-4 ↗
12. Bite forces used during chewing of food
13. In vivo vertical forces on implants
14. A novel bite force recorder and maximal isometric bite force values for healthy young adults
15. Evaluation of loading conditions on fatigue-failed implants by fracture surface analysis
16. The binary TiZr alloy—A newly developed Ti alloy for use in dental implants
17. Watanabe, S., Nakano, T., Ono, S., Yamanishi, Y., Matsuoka, T., and Ishigaki, S. (2022). Fracture Resistance of Zirconia Abutments with or without a Titanium Base: An In Vitro Study for Tapered Conical Connection Implants. Materials, 15.10.3390/ma15010364 ↗