Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty
Source abstract
Abstract
Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one case and pseudo tumor formation in another case. Furthermore, we suggest a diagnostic algorithm for joint pain after MoM trapeziometacarpal joint replacement based on published experiences from MoM hip prostheses and adverse reactions to metal.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
University Clinic for Hand, Hip and Knee Surgery, Regional Hospital Holstebro, Aarhus University, Lægårdvej 12, DK-7500 Holstebro, Denmark
References (36)
Show source-provided references
1. Wajon, A., Carr, E., Edmunds, I., and Ada, L. (2009). Surgery for thumb (trapeziometacarpal joint) osteoarthritis. Cochrane Database Syst. Rev., 4.10.1002/14651858.CD004631.pub3 ↗
2. Outcome comparison of primary trapeziectomy versus secondary trapeziectomy following failed total trapeziometacarpal joint replacement10.1016/j.jhsa.2013.01.030 ↗
3. Surgical treatment of trapeziometacarpal joint arthritis—A historical perspective10.1007/s11999-013-3374-z ↗
4. Electra trapeziometacarpal prosthesis: Results of the first 100 cases10.1016/J.JHSB.2006.05.019 ↗
5. Prospective 1-year follow-up study comparing joint prosthesis with tendon interposition arhtroplasty in treatment of trapeziometacarpal osteoarthritis10.1016/j.jhsa.2008.04.028 ↗
6. Cobalt and chromium ion release after large-diameter metal-on-metal total hip arthroplasty10.1016/j.arth.2011.12.016 ↗
7. Material loss at the taper junction of retrieved large head metal-on-metal total hip replacement10.1002/jor.22431 ↗
8. Metal release from hip prostheses: Cobalt and chromium toxicity and the role of the clinical laboratory10.1515/cclm-2012-0492 ↗
9. The hip society—Algorithmic approach to diagnosis and management of metal-on-metal arhtroplasty10.1302/0301-620X.94B11.30680 ↗
10. Metal allergy in patients with total hip replacement: A review10.1177/0300060513476583 ↗
11. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?10.1007/s11999-014-3824-2 ↗
12. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study10.2106/00004623-200501000-00006 ↗
13. The natural history of inflammatory pseudotumours in asymptomatic patients after metal-on-metal hip arthroplasty10.1007/s11999-013-2944-4 ↗
14. Evaluation and management of metal hypersensitivity in total joint arthroplasty: A systematic review10.1615/JLongTermEffMedImplants.2014010277 ↗
15. (2007). BS ISO 5832-12:2007 Implants for Surgery—Metallic Materials—Part 12: Wrought Cobalt-Chromium-Molybedenium Alloy, ISO.
16. Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty10.1002/jor.21015 ↗
17. Few adverse reactions to metal on metal articulation in total hip arthroplasty in a review study on 358 consecutive cases with 1 to 5 years follow-up10.2174/1874325001206010366 ↗
18. Pseudotumors are common in well-positioned low-wearing metal-on-metal hips10.1007/s11999-011-2201-7 ↗
19. High prevalence of pseudotumors in patients with a Birmingham hip resurfacing prosthesis: A prospective cohort study of one hundred and twenty-nine patients10.2106/JBJS.L.00716 ↗
20. Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal total hip replacement10.2106/JBJS.L.01481 ↗
21. Metal ion levels and functional results following resurfacing hip arthroplasty versus conventional small-diameter metal-on-metal total hip arthroplasty; a 3 to 5 year follow-up of a randomized controlled trial10.1016/j.arth.2014.07.036 ↗
22. Periprosthetic tissue metal content but not serum metal content predicts the type of tissue response in failed small-diameter metal-on-metal total hip arthroplasties10.2106/JBJS.L.01273 ↗
23. Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty10.1016/j.arth.2004.09.012 ↗
24. Longitudinal magnetic resonance imaging of pseudotumors following metal-on-metal total hip arthroplasty10.1016/j.arth.2014.05.006 ↗
25. Smith, E., Mehta, A.J., and Statham, B.N. (2009). Metal sensitivity to Elektra prostheses—Two cases from a metal on metal implant for hand joint replacement. Contact Dermatit., 60.10.1111/j.1600-0536.2009.01535.x ↗
26. Hypersensitivity reations in total hip arthroplasty10.3928/01477447-20070901-12 ↗
27. The painful metal-on-metal hip resurfacing10.1302/0301-620X.91B6.21682 ↗
28. Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties10.3109/17453670903473016 ↗
29. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: A case-control study using three-dimensional computed tomography and magnetic resonance imaging10.2106/JBJS.J.01508 ↗
30. Revision of metal-on-metal hip arthroplasty in a tertiary center—A prospective study of 39 hips with between 1 and 4 years follow up10.3109/17453674.2013.797313 ↗
31. Patients with metal-on-metal articulation in trapeziometacarpal total joint arthroplasty may have elevated serum chrome and cobalt10.1177/1753193413487685 ↗
32. Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hip replacement arhtroplasty10.2106/00004623-197759020-00004 ↗
33. Hypersensitivity reactions to metallic implants—Diagnostic algorithm and suggested patch test series for clinical use10.1111/j.1600-0536.2011.01971.x ↗
34. Metal allergy and second-generation metal-on-metal arthroplasties10.1111/j.1600-0536.2011.01970.x ↗
35. Diagnostic accuracy of MRI versus ultrasound for detecting pseudtotumors in asymptomatic metal-on-metal THA10.1007/s11999-013-3181-6 ↗
36. (2012). Medical Device Alert, MDA/2012/036, Medicines and Healthcare Products Regulatory Agency.