journal article·2025-12-26Open access

Multilayer Ti–Cu Oxide Coatings on Ti6Al4V: Balancing Antibacterial Activity, Mechanical Strength, Corrosion Resistance, and Cytocompatibility

Stefan Valkov, Maria P. Nikolova, Tanya V. Dimitrova, Maria Elena Stancheva, Dimitar Dechev, Nikolay Ivanov, Yordan Handzhiyski, Andreana Andreeva, Maria Ormanova, Angel Anchev, Margarita D. Apostolova

Abstract

Titanium alloys are widely used for biomedical implants, but their performance is limited by wear, corrosion, and susceptibility to bacterial colonisation. To overcome these drawbacks, multilayer Ti–Cu oxide coatings were deposited on Ti6Al4V substrates using direct current magnetron sputtering. Two multilayer architectures (6 × 2 and 12 × 2 TiO2/CuO bilayers) were fabricated and evaluated for their structural, mechanical, electrochemical, and biological properties. SEM/EDS and XRD confirmed well-adhered crystalline coatings consisting of rutile/anatase TiO2 and monoclinic CuO with uniform elemental distribution. The coatings increased surface roughness, improved adhesion, and enhanced hardness by up to ~180% compared to uncoated Ti6Al4V alloy. Compared to the bare substrate, electrochemical testing in simulated body fluid showed higher corrosion resistance of both coated samples, but particularly for the 12 × 2 multilayers. Both architectures provided sustained Cu2+ release over seven days without a burst effect. In vitro biological testing showed that both multilayer coatings achieved over 96% inhibition of Gram-positive bacteria such as Staphylococcus aureus and Bacillus subtilis, while exhibiting moderate antibacterial effects against Gram-negative strains (Escherichia coli, Pseudomonas aeruginosa). Despite the presence of copper, MG-63 osteoblast-like cells demonstrated sustained viability and successful extracellular matrix mineralisation, indicating excellent cytocompatibility of the coatings with bone-forming cells. These results demonstrate that multilayer Ti–Cu oxide coatings can effectively balance antibacterial performance, corrosion resistance, mechanical strength, and support bone cell integration, making them a promising strategy for the surface modification of titanium-based biomedical implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Magnesium Alloys: Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Electronics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee Blvd., 1784 Sofia, Bulgaria

Department of Mathematics, Informatics and Natural Sciences, Technical University of Gabrovo, 4 H. Dimitar Str., 5300 Gabrovo, Bulgaria

Department of Material Science and Technology, University of Ruse “Angel Kanchev”, 8 Studentska Str., 7017 Ruse, Bulgaria

Roumen Tsanev Institute of Molecular Biology, Bulgarian Academy of Sciences, Acad. Georgi Bonchev Str., Bl. 21, 1113 Sofia, Bulgaria

Faculty of Physics, Sofia University “St. Kliment Ohridski”, 5 James Bourchier Blvd, 1164 Sofia, Bulgaria

Department of Material Science and Mechanics of Materials, Technical University of Gabrovo, 4 H. Dimitar Str., 5300 Gabrovo, Bulgaria

Funding

Bulgarian National Science Fund

References (86)

Show source-provided references
1. Cold atmospheric plasma in combination with mechanical treatment improves osteoblast growth on biofilm covered titanium discs10.1016/j.biomaterials.2015.02.035 ↗
2. Wu, Y., Zhou, H., Zeng, Y., Xie, H., Ma, D., Wang, Z., and Liang, H. (2022). Recent Advances in Copper-Doped Titanium Implants. Materials, 15.10.3390/ma15072342 ↗
3. Infection After Primary Total Hip Arthroplasty10.3928/01477447-20140401-08 ↗
4. Fabrication of biopolymers reinforced TNT/HA coatings on Ti: Evaluation of its corrosion resistance and biocompatibility10.1016/j.electacta.2014.10.055 ↗
5. Wear debris characterization and corresponding bio-logical response: Artificial hip and knee joints10.3390/ma7020980 ↗
6. Kartini, I., Khairani, I.Y., Triyana, K., and Wahyuni, S. (2018). Nanostructured titanium dioxide for functional coatings. Titanium Dioxide: Material for a Sustainable Environment, Intech Open.10.5772/intechopen.74555 ↗
7. A novel antibacterial titania coating: Metal ion toxicity and in vitro surface colonization10.1007/s10856-005-4422-3 ↗
8. Antibacterial metals and alloys for potential biomedical implants
9. Tao, Y., Ayre, W., Jiang, L., Chen, S., Dong, Y., Wu, L., Jiao, Y., and Liu, X. (2025). Enhanced functionalities of biomaterials through metal ion surface modification. Front. Bioeng. Biotechnol., 13.10.3389/fbioe.2025.1522442 ↗
10. Copper source determines chemistry and topography of implant coatings to optimally couple cellular responses and antibacterial activity
11. The dual function of Cu-doped TiO2 coatings on titanium for application in percutaneous implants10.1039/C6TB00563B ↗
12. Enhanced photocatalytic and antibacterial ability of Cu-Doped anatase TiO2 thin films: Theory and experiment10.1021/acsami.9b22056 ↗
13. Photocatalytic activity and antibacterial behavior of TiO2 coatings co-doped with copper and nitrogen via sol–gel method10.1007/s10971-019-05085-1 ↗
14. On the emergence of antibacterial and antiviral copper cold spray coatings10.1186/s13036-021-00256-7 ↗
15. Molecular mechanisms of osteogenesis and antibacterial activity of Cu-bearing Ti alloy in a bone defect model with infection in vivo
16. A nano-structured TiO2/CuO/Cu2O coating on Ti-Cu alloy with dual function of antibacterial ability and osteogenic activity10.1016/j.jmst.2021.04.056 ↗
17. Enhanced antibacterial activity of Ti-Cu alloy by selective acid etching10.1016/j.surfcoat.2021.127478 ↗
18. Mao, X., Shi, A., Wang, R., Nie, J., Qin, G., Chen, D., and Zhang, E. (2022). The Influence of Copper Content on the Elastic Modulus and Antibacterial Properties of Ti-13Nb-13Zr-xCu Alloy. Metals, 12.10.3390/met12071132 ↗
19. Microstructure and antibacterial properties of Cu-doped TiO2 coating on titanium by micro-arc oxidation10.1016/j.apsusc.2013.12.083 ↗
20. One-step fabrication of cytocompatible micro/nano-textured surface with TiO2 mesoporous arrays on titanium by high current anodization10.1016/j.electacta.2016.03.119 ↗
21. Antibacterial property, angiogenic and osteogenic activity of Cu-incorporated TiO2 coating10.1039/C4TB00923A ↗
22. Mechanical Properties and Shape Memory Behavior of Ti-Nb Alloys10.2320/matertrans.45.2443 ↗
23. Copper and its complexes in medicine: A biochemical approach10.4061/2011/594529 ↗
24. Structural, mechanical and tribological behavior of TiCN, CrAlN and BCN coatings in lubricated and non-lubricated environments in manufactured devices10.1016/j.matchemphys.2020.123164 ↗
25. Effect of radiofrequency power sputtering on silver-palladium nano-coatings for mild steel corrosion protection in 3.5% NaCl solution10.1007/s11665-020-05269-9 ↗
26. Ionized vapor deposition of antimicrobial Ti–Cu films with controlled copper release10.1016/j.tsf.2013.11.001 ↗
27. Antibacterial and Biocompatible Titanium-Copper Oxide Coating May Be a Potential Strategy to Reduce Periprosthetic Infection: An In Vitro Study10.1007/s11999-016-4713-7 ↗
28. Effects of surface roughening on antibacterial and osteogenic properties of TiCu alloys with different Cu contents10.1016/j.jmst.2021.01.067 ↗
29. Einhorn, T.A., O’Keefe, R.J., and Buckwalter, J.A. (2007). Orthopaedic Basic Science: Foundations of Clinical Practice, American Academy of Orthopaedic Surgeons.
30. Ilievska, I., Ivanova, V., Dechev, D., Ivanov, N., Ormanova, M., Nikolova, M.P., Handzhiyski, Y., Andreeva, A., Valkov, S., and Apostolova, M.D. (2024). Influence of Thickness on the Structure and Biological Response of Cu-O Coatings Deposited on cpTi. Coatings, 14.10.3390/coatings14040455 ↗
31. Valkov, S., Parshorov, S., Andreeva, A., Bezdushnyi, R., Nikolova, M., Dechev, D., Ivanov, N., and Petrov, P. (2019). Influence of Electron Beam Treatment of Co–Cr Alloy on the Growing Mechanism, Surface Topography, and Mechanical Properties of Deposited TiN/TiO2 Coatings. Coatings, 9.10.3390/coatings9080513 ↗
32. Fiji: An open-source platform for biological-image analysis10.1038/nmeth.2019 ↗
33. Virtual Orientation Tools (VOTj): Fiji plugins for object centering and alignment
34. New competitive enzyme-linked immunosorbent assay for determination of metallothionein in tissue and sera10.1016/S0039-9140(97)00341-X ↗
35. Synthesis of ductile titanium–titanium boride (Ti-TiB) composites with a beta-titanium matrix: The nature of TiB formation and composite properties10.1007/s11661-003-0249-z ↗
36. Study of the influence of electron beam treatment of Ti5Al4V substrate on the mechanical properties and surface topography of multilayer TiN/TiO2 coatings10.1016/j.vacuum.2018.05.026 ↗
37. Effects of Ta content on Young’s modulus and tensile properties of binary Ti–Ta alloys for biomedical applications10.1016/j.msea.2003.12.011 ↗
38. Young’s modulus and damping of Ti6Al4V alloy as a function of heat treatment and oxygen concentration10.1016/0921-5093(90)90097-M ↗
39. Influence of thickness on the crystallography and surface topography of TiN nano-films deposited by reactive DC and pulsed magnetron sputtering10.1016/j.tsf.2012.03.097 ↗
40. Panjan, P., Drnovšek, A., Gselman, P., Čekada, M., and Panjan, M. (2020). Review of Growth Defects in Thin Films Prepared by PVD Techniques. Coatings, 10.10.3390/coatings10050447 ↗
41. Microstructure and properties of monolayer, bilayer and multilayer Ta2O5-based coatings on biomedical Ti-6Al-4V alloy by magnetron sputtering10.1016/j.ceramint.2020.08.230 ↗
42. Nanostructured multilayer CAE-PVD coatings based on transition metal nitrides on Ti6Al4V alloy for biomedical applications10.1016/j.ceramint.2023.04.169 ↗
43. A review on the wettability of dental implant surfaces I: Theoretical and experimental aspects10.1016/j.actbio.2014.02.040 ↗
44. Mediation of biomaterial-cell interactions by adsorbed proteins: A review10.1089/ten.2005.11.1 ↗
45. Gilbert, P., Allison, D., Brading, M., Verran, J., and Walker, J. (2001). The role of hydrophobicity in bacterial adhesion. Biofilm Community Interactions: Chance or Necessity?, BioLine.
46. Directing the fate of human and mouse mesenchymal stem cells by hydroxyl–methyl mixed self-assembled monolayers with varying wettability10.1039/C4TB00597J ↗
47. Ríos-Carrasco, B., Lemos, B.F., Herrero-Climent, M., Gil Mur, F.J., and Ríos-Santos, J.V. (2021). Effect of the Acid-Etching on Grit-Blasted Dental Implants to Improve Osseointegration: Histomorphometric Analysis of the Bone-Implant Contact in the Rabbit Tibia Model. Coatings, 11.10.3390/coatings11111426 ↗
48. Investigation of tantalum oxynitride for hard and anti-corrosive coating application in diluted hydrochloric acid solutions10.1016/j.mtcomm.2020.101113 ↗
49. Response of boride coating on the Ti-6Al-4V alloy to corrosion and fretting corrosion behavior in Ringer’s solution for bio-implant application10.1016/j.apsusc.2017.09.223 ↗
50. Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes10.1016/j.electacta.2016.01.216 ↗
51. Comparing the electrochemical behaviour of applied CrN/TiN nanoscale multilayer and TiN single-layer coatings deposited by CAE-PVD method10.1080/21870764.2020.1756065 ↗
52. Corrosion resistance for biomaterial applications of TiO2 films deposited on titanium and stainless steel by ion-beam-assisted sputtering10.1002/(SICI)1097-4636(19970605)35:3<309::AID-JBM5>3.0.CO;2-L ↗
53. SVET, SKP and EIS study of the corrosion be-haviour of high strength Al and Al-Li alloys used in aircraft fabrication10.1016/j.corsci.2014.03.001 ↗
54. Cu and Si co-doped microporous TiO2 coating for osseointegration by the coordinated stimulus action10.1016/j.apsusc.2019.144072 ↗
55. In vivo quantification of gentamicin released from an implant coating10.1177/0885328216630912 ↗
56. Reducing implant-related infections: Active release strategies10.1039/b515219b ↗
57. Catalytic formation of nitric oxide mediated by Ti–cu coatings provides multifunctional interfaces for cardiovascular applications10.1002/admi.201701487 ↗
58. Deposition of thin titanium–copper films with antimicrobial effect by advanced magnetron sputtering methods10.1016/j.msec.2011.06.009 ↗
59. Antibacterial activities against porphyromonas gingivalis and biological characteristics of copper-bearing PEO coatings on magnesium10.1016/j.jmst.2020.05.025 ↗
60. Metal-based approaches for the fight against antimicrobial resistance: Mechanisms, opportunities, and challenges10.1021/jacs.4c16035 ↗
61. Effect of divalent cation removal on the structure of gram-negative bacterial outer membrane models10.1021/la504407v ↗
62. Gugala, N., Vu, D., Parkins, M.D., and Turner, R.J. (2019). Specificity in the susceptibilities of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus clinical isolates to six metal antimicrobials. Antibiotics, 8.10.3390/antibiotics8020051 ↗
63. Teksoy, A., and Özyiğit, M.E. (2025). A Study on the Use of Copper Ions for Bacterial Inactivation in Water. Water, 17.10.3390/w17192797 ↗
64. Antimicrobial activity of copper alloys against invasive multidrug-resistant nosocomial pathogens10.1007/s00284-015-0840-8 ↗
65. Copper-containing mesoporous bioactive glass nanoparticles as multifunctional agent for bone regeneration10.1016/j.actbio.2017.04.012 ↗
66. Krakhmalev, P., Yadroitsev, I., Yadroitsava, I., and De Smidt, O. (2017). Functionalization of Biomedical Ti6Al4V via In Situ Alloying by Cu during Laser Powder Bed Fusion Manufacturing. Materials, 10.10.3390/ma10101154 ↗
67. Dye degradation performance, bactericidal behavior and molecular docking analysis of Cu-doped TiO2 nanoparticles10.1039/D0RA04851H ↗
68. Antibacterial titanium surfaces for medical implants10.1016/j.msec.2015.12.062 ↗
69. Targeting microbial biofilms: Current and prospective therapeutic strategies10.1038/nrmicro.2017.99 ↗
70. Antimicrobial mechanism of cuprous oxide (Cu2O) coatings10.1016/j.jcis.2023.08.136 ↗
71. Antimicrobial and superhydrophobic CuONPs/TiO2 hybrid coating on polypropylene substrates against biofilm formation10.1021/acsomega.4c07345 ↗
72. Bacterial killing by dry metallic copper surfaces10.1128/AEM.01599-10 ↗
73. Surface structure influences contact killing of bacteria by copper10.1002/mbo3.170 ↗
74. Contact killing of bacteria on copper is suppressed if bacterial-metal contact is prevented and is induced on iron by copper ions10.1128/AEM.03608-12 ↗
75. Killing of bacteria by copper surfaces involves dissolved copper10.1128/AEM.00424-10 ↗
76. Antimicrobial effect of copper surfaces on bacteria isolated from poultry meat10.1016/j.bjm.2018.06.008 ↗
77. Biological properties of copper: Antibacterial, osteogenesis of biomaterials
78. Ngece, K., Khwaza, V., Paca, A.M., and Aderibigbe, B.A. (2025). The Antimicrobial Efficacy of Copper Complexes: A Review. Antibiotics, 14.10.3390/antibiotics14050516 ↗
79. Hu, P., Zhu, L., Tian, C., Xu, G., Zhang, X., and Cai, G. (2024). Study of Anticorrosion and Antifouling Properties of a Cu-Doped TiO2 Coating Fabricated via Micro-Arc Oxidation. Materials, 17.10.3390/ma17010217 ↗
80. Mechanoreciprocity in cell migration10.1038/s41556-017-0012-0 ↗
81. Measuring mechanical tension across vinculin reveals regulation of focal adhesion dynamics10.1038/nature09198 ↗
82. Actomyosin contractility as a mechanical checkpoint for cell state transitions10.1038/s41598-022-20089-8 ↗
83. YAP regulates cell mechanics by controlling focal adhesion assembly10.1038/ncomms15321 ↗
84. Control of cellular responses to mechanical cues through YAP/TAZ regulation10.1074/jbc.REV119.007963 ↗
85. Integrins as biomechanical sensors of the microenvironment10.1038/s41580-019-0134-2 ↗
86. Mechanical factors influence β-catenin localization and barrier properties10.1093/intbio/zyae013 ↗