journal article·2025-11-25Open access

Grain Size and Electrochemical Surface Modification Effects on Corrosion, Biological, and Technological Properties of CP Titanium Implants

Josef Hlinka, Daniel Cvejn, Ludek Dluhos, Vaclav Babuska, Kristina Cabanova, Jana Dvorakova, Anastasia Volodarskaja, Ruslan Z. Valiev, Nadimul H. Faisal, Katerina Peterek Dedkova, Renata Palupcikova, Vlastimil Vodarek

Journal of Functional Biomaterials· Volume 16· Issue 12

Abstract

Commercially pure (CP) titanium is widely used for long-term biomedical implants due to its high biocompatibility and corrosion resistance. However, its relatively low strength limits its use in highly loaded applications. Ultrafine-grained (UFG) titanium obtained through severe plastic deformation offers enhanced mechanical performance while maintaining the stability of CP titanium. This study investigates how electrochemical surface modification by anodization affects the corrosion, biological performance, and technological behavior of UFG titanium. TiO2 layers with nanotubular and nanoporous morphologies were produced at anodization voltages between 20 and 60 V. Corrosion tests in physiological solution confirmed stable passive behavior with corrosion rates below 4 µm year−1, and surface wettability increased markedly with anodization. Osteoblast-like MG-63 cells exhibited good viability on all anodized surfaces, with improved adhesion and proliferation on samples anodized at 60 V. The porous TiO2 layers were successfully intercalated with dimethyl sulfoxide and ibuprofen, demonstrating potential for local drug delivery. Implantation simulations on real Nanoimplant® prototypes confirmed sufficient mechanical stability of the anodized layer. Overall, the optimized anodization of UFG titanium enhances its biological response while maintaining corrosion resistance, supporting its clinical use in long-term dental and orthopedic implants with integrated drug-release functionality.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Magnesium Alloys: Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Engineering and Recycling, Faculty of Materials and Technology, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava-Poruba, Czech Republic

Centre for Advanced Innovation Technologies, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava-Poruba, Czech Republic

TIMPLANT, Ltd., Sjednoceni 77/1, Polanka nad Odrou, 725 25 Ostrava-Poruba, Czech Republic

Department of Medical Chemistry and Biochemistry, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, 323 00 Pilsen, Czech Republic

Department of Mining Engineering and Safety, Faculty of Mining and Geology, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava-Poruba, Czech Republic

Institute of Physics of Advanced Materials, Ufa University of Science and Technology, Ufa 450076, Russia

Liaoning Academy of Materials, 280, Chuangxin Road, Hunnan District, Shenyang 110167, China

School of Computing, Engineering and Technology, Robert Gordon University, Garthdee Road, Aberdeen AB10 7GJ, UK

Funding

European Union and from the state budget of the Czech Republic

References (100+)

Show source-provided references
1. Etruscan Gold Dental Appliances: Three Newly “Discovered” Examples10.2307/506579 ↗
2. Tissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
3. Titanium Alloys for Dental Implants: A Review10.3390/prosthesis2020011 ↗
4. Evolution of the Passive Film on Mechanically Damaged Nitinol10.1002/jbm.a.32046 ↗
5. Hanawa, T. (2019). Titanium–Tissue Interface Reaction and Its Control with Surface Treatment. Front. Bioeng. Biotechnol., 7.10.3389/fbioe.2019.00170 ↗
6. Commercially Pure Titanium (Cp-Ti) versus Titanium Alloy (Ti6Al4V) Materials as Bone Anchored Implants—Is One Truly Better than the Other?10.1016/j.msec.2016.01.032 ↗
7. Improving the Fatigue Behavior of Dental Implants through Processing Commercial Purity Titanium by Equal-Channel Angular Pressing10.1016/j.msea.2014.09.099 ↗
8. In Vivo Behavior of Surface Modified Ti6Al7Nb Alloys Used in Selective Laser Melting for Custom-Made Implants. A Preliminary Study
9. Wear and Corrosion Behaviour of Ti-13Nb-13Zr and Ti-6Al-4V Alloys in Simulated Physiological Solution10.1016/j.corsci.2010.11.014 ↗
10. Fatigue Performance and Cyto-Toxicity of Low Rigidity Titanium Alloy, Ti-29Nb-13Ta-4.6Zr10.1016/S0142-9612(03)00069-3 ↗
11. Corrosion of Titanium: Part 1: Aggressive Environments and Main Forms of Degradation
12. Allergic Reaction to Vanadium Causes a Diffuse Eczematous Eruption and Titanium Alloy Orthopedic Implant Failure
13. Nanostructured Titanium for Biomedical Applications10.1002/adem.200800026 ↗
14. Valiev, R.Z., Sabirov, I., Zemtsova, E.G., Parfenov, E.V., Dluhoš, L., and Lowe, T.C. (2018). Nanostructured Commercially Pure Titanium for Development of Miniaturized Biomedical Implants. Titanium in Medical and Dental Applications, Woodhead Publishing.10.1016/B978-0-12-812456-7.00018-4 ↗
15. Corrosion Properties of ECAP Titanium with Bioactive Oxide Coating in Physiological Solution10.4028/www.scientific.net/KEM.810.52 ↗
16. Effect of Surface Grain Boundary Density on Preosteoblast Proliferation on Titanium10.1080/21663831.2020.1744758 ↗
17. Enhanced in Vitro Biocompatibility of Ultrafine-Grained Titanium with Hierarchical Porous Surface10.1016/j.apsusc.2011.01.062 ↗
18. A Brief Historical Perspective on Dental Implants, Their Surface Coatings and Treatments10.2174/1874210601408010050 ↗
19. Zigterman, B.G.R., Van den Borre, C., Braem, A., and Mommaerts, M.Y. (2019). Titanium Surface Modifications and Their Soft-Tissue Interface on Nonkeratinized Soft Tissues—A Systematic Review (Review). Biointerphases, 14.10.1116/1.5113607 ↗
20. Bioceramics: Past, Present and for the Future10.1016/j.jeurceramsoc.2007.12.001 ↗
21. Biological Reactions to Different Dental Implant Surface Treatments
22. Thermal Stability and Annealing Behaviour of Ultrafine Grained Commercially Pure Titanium10.1016/j.msea.2011.10.062 ↗
23. Surface Treatments and Roughness Properties of Ti-Based Biomaterials10.1023/B:JMSM.0000042679.28493.7f ↗
24. Kazek-Kęsik, A., Leśniak, K., Orzechowska, B.U., Drab, M., Wiśniewska, A., and Simka, W. (2018). Alkali Treatment of Anodized Titanium Alloys Affects Cytocompatibility. Metals, 8.10.3390/met8010029 ↗
25. A Review on TiO2 Nanotubes: Influence of Anodization Parameters, Formation Mechanism, Properties, Corrosion Behavior, and Biomedical Applications10.1007/s40735-015-0024-x ↗
26. Enhanced Corrosion Resistance of TA2 Titanium via Anodic Oxidation in Mixed Acid System10.20964/2017.04.69 ↗
27. TiO2 Nanotube Platforms for Smart Drug Delivery: A Review10.2147/IJN.S108847 ↗
28. Jang, I., Choi, D.S., Lee, J.K., Kim, W.T., Cha, B.K., and Choi, W.Y. (2017). Effect of Drug-Loaded TiO2 Nanotube Arrays on Osseointegration in an Orthodontic Miniscrew: An in-Vivo Pilot Study. Biomed. Microdevices, 19.10.1007/s10544-017-0237-5 ↗
29. Use of Anodized Titanium Alloy as Drug Carrier: Ibuprofen as Model of Drug Releasing10.1016/j.ijpharm.2015.07.046 ↗
30. (2015). Standard Specification for Titanium and Titanium Alloy Strip, Sheet, and Plate (Standard No. ASTM B265-15).
31. Susceptibility of 316L Stainless Steel to Crevice Corrosion in Submersible Solenoid Valve10.1002/maco.201005917 ↗
32. Synthesis of Titania Nanotube Arrays by Anodization
33. Thermodynamic Stability Relations in Redox Systems10.1021/es051749i ↗
34. Nanoporous TiO2 and WO3 Films by Anodization of Titanium and Tungsten Substrates: Influence of Process Variables on Morphology and Photoelectrochemical Response10.1021/jp064527v ↗
35. Corrosion Properties of Anodized Titanium10.12776/ams.v23i3.982 ↗
36. Experimental Investigation of Long-Term Ageing Effect on the Structural and Electrochemical Behaviour of Self-Organized TiO2 Array Nanotubes on Ti-6Al-4V Alloy10.2174/2210681213666230427154325 ↗
37. Morphology and Electronic Properties of TiO2 Nanotubes Arrays Synthesized by Electrochemical Method10.2174/2210681208666180411154247 ↗
38. Rosenbloom, S.N., and Corbett, R.A. (2008). An Assessment of ASTM F 2129 Test Results Comparing Nitinol to Other Implant Alloys. SMST-2006-Proceedings of the International Conference on Shape Memory and Superelastic Technologies, Asilomar Conference Center.
39. (2014). Standard Test Method for Pitting or Crevice Corrosion of Metallic Surgical Implant Materials (Standard No. ASTM F746-04).
40. Olson, M.P., and Lacourse, W.R. (2004). Voltammetry. Analytical Instrumentation Handbook, CRC Press. [3rd ed.].10.1201/9780849390395.ch17 ↗
41. Linear Polarization Resistance Tests on Corrosion Protection Degree of Post-Tensioning Grouts
42. Control of the Wetting Properties of an AISI 316L Stainless Steel Surface by Femtosecond Laser-Induced Surface Modification10.1088/0960-1317/22/10/105019 ↗
43. The Measurement of the Surface Energy of Solids by Sessile Drop Accelerometry10.1007/s12217-018-9596-7 ↗
44. Synthesis and Characterization of Titania Nanotubes by Anodizing of Titanium in Fluoride Containing Electrolytes10.1007/s13204-017-0608-5 ↗
45. Comparison of Fibroblast and Osteoblast Response to Cultivation on Titanium Implants with Different Grain Sizes10.1155/2015/920893 ↗
46. Babuska, V., Dobra, J.K., Dluhos, L., Dvorakova, J., Moztarzadeh, J., Hrusak, D., and Kulda, V. (2020). Repeated Exposure of Nanostructured Titanium to Osteoblasts with Respect to Peri-Implantitis. Materials, 13.10.3390/ma13030697 ↗
47. Biomedical Applications of Titanium and Its Alloys10.1007/s11837-008-0031-1 ↗
48. Ultrafine Grained Titanium for Biomedical Applications: An Overview of Performance10.1016/j.jmrt.2013.07.003 ↗
49. Nanostructured SPD Processed Titanium for Medical Implants10.4028/www.scientific.net/MSF.584-586.49 ↗
50. Impacts of 3D Bone-to- Implant Contact and Implant Diameter on Primary Stability of Dental Implant10.1016/j.jfma.2017.05.005 ↗
51. Juniper Wood as a Possible Implant Material10.1002/jbm.a.10437 ↗
52. The Effects of Dynamic Loading on Intracalcaneal Wood Implants and on the Tissues Surrounding Them10.1007/BF00450228 ↗
53. Influence of Surgical Technique, Implant Shape and Diameter on the Primary Stability in Cancellous Bone10.1111/j.1365-2842.2010.02117.x ↗
54. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis10.11607/jomi.6285 ↗
55. Surgical Guidelines for Dental Implant Placement10.1038/sj.bdj.4813947 ↗
56. Surgical Guide for Dental Implant Placement10.1016/S0022-3913(00)80018-9 ↗
57. Interpretation of Open Circuit Potential of Two Titanium Alloys for a Long Time Immersion in Physiological Fluid
58. Validation of Corrosion Rates Measured by the Tafel Extrapolation Method10.1016/j.corsci.2005.05.046 ↗
59. Corrosion Behaviour of Ultra Fine Grained Titanium in Simulated Body Fluid for Implant Application
60. Predicting the Structure and Stability of Titanium Oxide Electrides10.1038/s41524-018-0131-6 ↗
61. Titanium Alloys for Biomedical Applications10.1016/j.msec.2005.08.032 ↗
62. Peters, M., Hemptenmacher, J., Kumpfert, J., and Leyens, C. (2005). Structure and Properties of Titanium and Titanium Alloys. Titanium and Titanium Alloys, Wiley-VCH.
63. Improvement to the Corrosion Resistance of Ti-Based Implants Using Hydrothermally Synthesized Nanostructured Anatase Coatings10.3390/ma7010180 ↗
64. Polarisation Measurements Used for Corrosion Rates Determination
65. Corrosion Characterization of Titanium Alloys by Electrochemical Techniques10.1016/j.electacta.2005.02.121 ↗
66. Modeling and Simulation of the Fluid-Solid Interaction in Wetting10.1088/1742-5468/2009/06/P06008 ↗
67. Effect of Surface Area, Pore Volume and Particle Size of P25 Titania on the Phase Transformation of Anatase to Rutile
68. Quantitative Metallography by Electron Backscattered Diffraction10.1046/j.1365-2818.1999.00578.x ↗
69. The Infrared Spectra of Some Ti-O-Si, Ti-O-Ti and Si-O-Si Compounds10.1021/j150555a010 ↗
70. Role of the Surface Lewis Acid and Base Sites in the Adsorption of CO2 on Titania Nanotubes and Platinized Titania Nanotubes: An in Situ FT-IR Study10.1021/jp402979m ↗
71. Growth, Spectral and Thermal Studies of Ibuprofen Crystals10.1002/crat.201100394 ↗
72. Electrochemical Surface Modification of Titanium in Dentistry10.4012/dmj.28.20 ↗
73. Morphological Development of Oxygen Bubbles in Anodic Alumina10.1149/1.1393428 ↗
74. Self-Ordering Electrochemistry: A Review on Growth and Functionality of TiO2 Nanotubes and Other Self-Aligned MOx Structures10.1039/b822726h ↗
75. Duvvuru, M.K., Han, W., Chowdhury, P.R., Vahabzadeh, S., Sciammarella, F., and Elsawa, S.F. (2019). Bone Marrow Stromal Cells Interaction with Titanium; Effects of Composition and Surface Modification. PLoS ONE, 14.10.1371/journal.pone.0216087 ↗
76. Effect of Anodization Parameters on the Structural Morphology of Titanium in Fluoride Containing Electrolytes10.1016/j.matchar.2012.06.005 ↗
77. Fabrication of Uniform Size Titanium Oxide Nanotubes: Impact of Current Density and Solution Conditions10.1016/j.scriptamat.2006.11.001 ↗
78. Lee, A.R., and Kim, J.Y. (2020). Highly Ordered TiO2 Nanotube Electrodes for Efficient Quasi-Solid-State Dye-Sensitized Solar Cells. Energies, 13.10.3390/en13226100 ↗
79. A Comparative Study of Anodized Titania Nanotube Architectures in Aqueous and Nonaqueous Solutions10.1557/jmr.2011.243 ↗
80. Effects of Annealing on Microstructure and Mechanical Properties of Nano-Grained Titanium Produced by Combination of Asymmetric and Symmetric Rolling10.1016/j.msea.2012.08.005 ↗
81. Biomedical Implants: Corrosion and Its Prevention—A Review10.2174/1877610801002010040 ↗
82. Different Constant Voltages of Anodization on the Corrosion Behavior of Ti-6Al-4V Alloy
83. Electrochemical Anodizing Treatment to Enhance Localized Corrosion Resistance of Pure Titanium
84. Anatase Nanotubes Synthesized by a Template Method and Their Application as a Green Photocatalyst10.1007/s10853-010-5044-9 ↗
85. Effect of Electrolyte Age and Potential Changes on the Morphology of TiO2 Nanotubes10.1016/j.jelechem.2015.11.002 ↗
86. Electrochemical Behavior of Three CP Titanium Dental Implants in Artificial Saliva10.1590/S1516-14392009000300018 ↗
87. Surface Characterization of Anodically Treated Β Titanium Alloy for Biomedical Applications
88. Improvement in Corrosion Resistance of Commercial Pure Titanium for the Enhancement of Its Biocompatibility10.1002/maco.200905534 ↗
89. Minhas, B., Dino, S., Zuo, Y., Qian, H., and Zhao, X. (2021). Improvement of Corrosion Resistance of TiO2 Layers in Strong Acidic Solutions by Anodizing and Thermal Oxidation Treatment. Materials, 14.10.3390/ma14051188 ↗
90. Cabrini, M., Lorenzi, S., Pastore, T., Pellegrini, S., Burattini, M., and Miglio, R. (2017). Study of the Corrosion Resistance of Austenitic Stainless Steels during Conversion of Waste to Biofuel. Materials, 10.10.3390/ma10030325 ↗
91. Hlinka, J., Lasek, S., Siostrzonek, R., and Faisal, N. (2017, January 24–26). Characterization of Hydroxyapatite Layer on AISI 316L Stainless Steel. Proceedings of the METAL 2017-26th International Conference on Metallurgy and Materials, Conference Proceedings, Brno, Czech Republic.
92. Eliaz, N. (2019). Corrosion of Metallic Biomaterials: A Review. Materials, 12.10.3390/ma12030407 ↗
93. Application-Wise Nanostructuring of Anodic Films on Titanium: A Review10.1080/17458080.2014.999261 ↗
94. Influence of the Ti Microstructure on Anodic Self-Organized TiO2 nanotube Layers Produced in Ethyene Glycol Electrolytes10.1016/j.apsusc.2016.03.012 ↗
95. (2001). Biological Evaluation of Medical Devices—Part 15: Identification and Quantification of Degradation Products from Metals and Alloys (Standard No. ISO/ES10993-15).
96. Sato, N. (2012). The Basic Process of Metallic Corrosion in Aqueous Solution Consists of the Anodic Dissolution of Metals and the Cathodic Reduction of Oxidants Present in the Solution. Basics of Corrosion Chemistry, Wiley-VCH.
97. Dual Effects and Mechanism of TiO2 Nanotube Arrays in Reducing Bacterial Colonization and Enhancing C3H10T1/2 Cell Adhesion
98. Wei, J., Igarashi, T., Okumori, N., Igarashi, T., Maetani, T., Liu, B., and Yoshinari, M. (2009). Influence of Surface Wettability on Competitive Protein Adsorption and Initial Attachment of Osteoblasts. Biomed. Mater., 4.10.1088/1748-6041/4/4/045002 ↗
99. BONE RESPONSE TO STAINLESS STEEL AND TITANIUM BONE PLATES: An Experimental Study on Animals10.1016/S0377-1237(17)31029-8 ↗
100. Anil, S., Anand, P.S., Alghamdi, H., and Janse, J.A. (2011). Dental Implant Surface Enhancement and Osseointegration. Implant Dentistry—A Rapidly Evolving Practice, Books on Demand.10.5772/16475 ↗