journal article·2023-12-23Open access

An In Vivo Investigation of Non-Metallic vs. Metallic Hand Scalers on Zirconia Implant-Supported Crowns: A Year-Long Analysis of Peri-Implant Maintenance

Dayna L. Roemermann, Reem Atout, Igor Pesun, Anastasia Kelekis-Cholakis, Chrysi Stavropoulou, Stefan N. Renvert, Rodrigo França

Abstract

This study examined whether the degree of abutment surface modification that may occur with regular periodontal instrumentation has a clinical impact in terms of increased plaque accumulation and increased peri-implant tissue inflammation on zirconia implant abutments. Thirteen patients who had zirconia implant crowns were recruited in this randomized clinical trial. Each patient acted as their control and had either the buccal or lingual surface of their screw-retained implant restoration scaled with a metallic scaler and the other surface with a non-metallic scaler at 3, 6, 9, and 12 months. Cytokine testing of the peri-implant crevicular fluid was completed at 0, 3, and 12 months for IL-2, IL-4, IL-6, IL-8, IL-10, TNF-α, or IFNγ. Implant crowns were removed at 12 months and evaluated under an atomic force microscope for the average roughness (Ra). The implant crowns were polished and re-inserted. The results were analyzed using the Kruskal–Wallis test, and post hoc tests were conducted with a significance level of α = 0.05. Significant differences in surface roughness (Ra) were observed between the metallic and non-metallic scalers. The median Ra values were 274.0 nm for metallic scalers and 147.1 nm for non-metallic scalers. However, there were no significant differences between the type of scaler used and the amount of clinical inflammation or cytokine production. Metallic scalers produced deeper, more aggressive surface alterations to the abutment/crown zirconia surface, but there was no statistically significant difference between the degree of surface alterations, amount of BOP, and the amplitude of cytokine inflammation produced.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dental Diagnostic and Surgical Sciences, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R3T 2N2, Canada

Department of Restorative Dentistry, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R3T 2N2, Canada

Oral Health Sciences, Kristianstad University, 291 88 Kristianstad, Sweden

Funding

Gerald Niznick College of Dentistry Endownmen Fund · Sunstar · Tepe · Colgate · HuFriedy

References (36)

Show source-provided references
1. The use of IMZ osseointegrated implants in partially and completely edentulous patients: Success and failure rates of 2023 implant cylinders up to 60+ months in function
2. A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants10.1034/j.1600-0501.1996.070405.x ↗
3. A meta-analysis of implants in partial edentulism10.1034/j.1600-0501.1998.090203.x ↗
4. Trends in Dental Implant Use in the U.S., 1999–2016, and Projections to 202610.1177/0022034518792567 ↗
5. Experimentally induced peri-implant mucositis. A clinical study in humans10.1034/j.1600-0501.1994.050409.x ↗
6. Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017WorldWorkshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions10.1002/JPER.17-0739 ↗
7. Management of peri-implantitis10.4103/1735-3327.104867 ↗
8. Guarnieri, R., Reda, R., Zanza, A., Miccoli, G., Di Nardo, D., and Testarelli, L. (2022). Can Peri-Implant Marginal Bone Loss Progression and a-MMP-8 Be Considered Indicators of the Subsequent Onset of Peri-Implantitis? A 5-Year Study. Diagnostics, 12.10.3390/diagnostics12112599 ↗
9. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: A systematic review and meta-analysis10.1111/clr.12631 ↗
10. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: An in vivo human study10.1902/jop.2004.75.2.292 ↗
11. Evaluation of the safety and efficiency of novel metallic ultrasonic scaler tip on titanium surfaces10.1111/j.1600-0501.2011.02302.x ↗
12. Effect of plastic-covered ultrasonic scalers on titanium implant surfaces10.1111/j.1600-0501.2011.02186.x ↗
13. The effect of five mechanical instrumentation protocols on implant surface topography and roughness. A scanning electron microscope and confocal laser scanning microscope analysis10.1111/clr.13446 ↗
14. Probing and Scaling Instrumentation on Implant Abutment Surfaces10.1097/ID.0b013e3182588822 ↗
15. Effects of Ultrasonic Scaler Tips and Toothbrush on Titanium Disc Surfaces Evaluated With Confocal Microscopy10.1097/SCS.0b013e31825e3ba6 ↗
16. Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments10.5051/jpis.2012.42.3.88 ↗
17. Treatment of Titanium Dental Implants With Three Piezoelectric Ultrasonic Scalers: An In Vivo Study10.1902/jop.2007.060496 ↗
18. The Comparative Effect of Ultrasonic Scalers on Titanium Surfaces: An In Vitro Study10.1902/jop.2004.75.9.1269 ↗
19. In Vitro Studies on the Effect of Cleaning Methods on Different Implant Surfaces10.1902/jop.1998.69.8.857 ↗
20. A comparative study of the effects of metallic, nonmetallic, and sonic instrumentation on titanium abutment surfaces
21. The qualitative effects of various types of hygiene instrumentation on commercially pure titanium and titanium alloy implant abutments: An in vitro and scanning electron microscope study10.1016/S0022-3913(97)70028-3 ↗
22. Effect of hygiene instrumentation on titanium abutments: A scanning electron microscopy study10.1016/0022-3913(92)90248-9 ↗
23. A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia10.3390/ma8030932 ↗
24. Kozmacs, C., Hollmann, B., Arnold, W.H., Naumova, E., and Piwowarczyk, A. (2017). Polishing of Monolithic Zirconia Crowns-Results of Different Dental Practitioner Groups. Dent. J., 5.10.3390/dj5040030 ↗
25. Sacher, E., and França, R. (2018). Dental Biomaterials, World Scientific.10.1142/10589 ↗
26. Evaluation of different methods to clean titanium abutments. A scanning electron microscopic study10.1034/j.1600-0501.1992.030304.x ↗
27. Surface alterations of several dental materials by a novel ultrasonic scaler tip
28. Design, manufacturing and clinical outcomes for additively manufactured titanium dental implants: A systematic review10.1016/j.dentre.2022.100041 ↗
29. Use of Il-1ß, Il-6, TNF-α and MMP-8 biomarkers to distinguish peri-implant diseases: A systematic review and meta-analysis10.1111/cid.12694 ↗
30. Could cytokine levels in the peri-implant crevicular fluid be used to distinguish between healthy implants and implants with peri-implantitis? A systematic review10.1111/jre.12354 ↗
31. Can peri-implant crevicular fluid assist in the diagnosis of peri-implantitis? A systematic review and meta-analysis10.1902/jop.2015.140603 ↗
32. Maintenance of Implant Patients: A Narrative Review10.1097/ID.0000000000000837 ↗
33. Molecular profiling of intrabony defects’ gingival crevicular fluid10.1111/jre.12948 ↗
34. A qualitative and quantitative analysis of the human gingival crevicular fluid proteome and metaproteome10.1002/pmic.202000321 ↗
35. Transcriptomic phases of periodontitis lesions using the nonhuman primate model10.1038/s41598-021-88803-6 ↗
36. Periodontal inflammation and distinct inflammatory profiles in saliva and GCF compared with serum and joints in rheumatoid arthritis patients10.1002/JPER.20-0051 ↗