Preclinical Performance of a Novel Dental Implant Design Reducing Mechanical Stress in Cortical Bone
Source abstract
Abstract
This animal study compared the healing performance of a novel implant design characterized by a shift in thread geometry and core diameter with two different surfaces with that of an apically tapered implant. Test Bioactive (n = 9), Test Porous (n = 7) and Control (n = 8) implants were placed in the mandibles of minipigs. Following healing, bone samples were harvested for determining bone-to-implant contact (BIC) and marginal bone loss (MBL). Comparative statistics were based on Levene’s test, Shapiro–Wilk tests, the Kruskal–Wallis test and Wilcoxon tests with Holm correction (α = 0.05). The mean undersizing of the osteotomy was 0.15 mm for Control, while in the test groups 0.33 mm and 0.34 mm were calculated. Insertion torques ranged from 61.5 Ncm (Control) to 76.1 Ncm (Test Bioactive). Maximum BIC was seen in Test Porous with 55.83%, while Test Bioactive showed only 48.11%. MBL was 4.1 mm in Test Bioactive, while Test Porous and Control exhibited 2.8 mm. No significant differences between the implant groups were observed (p > 0.05). Despite greater undersizing, the novel implant type performed comparably to the established Control implants. The rougher surface of the bioactive implants increased the insertion torque and led to more MBL.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, Saarland University, 66421 Homburg, Germany
Institute for Clinical and Experimental Surgery, Saarland University, 66421 Homburg, Germany
Department of Prosthodontics, Philipps University Marburg, 35039 Marburg, Germany
Funding
AlfaGate, Bonn, Germany · Open Access Publishing Fund of Philipps-Universität Marburg
References (35)
Show source-provided references
1. Immediate Loading: Are Implant Surface and Thread Design More Important Than Osteotomy Preparation?
2. Thermal exposure of implant osteotomies and its impact on osseointegration-A preclinical in vivo study10.1111/clr.13729 ↗
3. Mechanical stress during implant surgery and its effects on marginal bone: A literature review
4. Aghvami, M., Brunski, J.B., Serdar Tulu, U., Chen, C.H., and Helms, J.A. (2018). A Thermal and Biological Analysis of Bone Drilling. J. Biomech. Eng., 140.10.1115/1.4040312 ↗
5. Addition of an irrigation channel to a surgical template to facilitate cooling during implant osteotomy10.1016/j.prosdent.2020.05.019 ↗
6. Gehrke, S.A., Bettach, R., Cayron, B., Boukhris, G., Dedavid, B.A., and Frutos, J.C.P. (2020). Development of a New Drill Design to Improve the Temperature Control during the Osteotomy for Dental Implants: A Comparative In Vitro Analysis. Biology, 9.10.3390/biology9080208 ↗
7. Influence of a Novel Drill Design on Heat Generation During Conventional and Guided Implant Osteotomy10.11607/jomi.8583 ↗
8. Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: An in vitro study10.1016/j.medengphy.2011.05.013 ↗
9. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model10.1111/clr.12032 ↗
10. Heat generated during seating of dental implant fixtures10.1563/AAID-JOI-D-13-00261 ↗
11. Determinants of temperature development during dental implant surgery10.3390/prosthesis6030046 ↗
12. A preclinical model links osseo-densification due to misfit and osseo-destruction due to stress/strain10.1111/clr.13537 ↗
13. Benchmark performance of anodized vs
14. Effects of condensation and compressive strain on implant primary stability: A longitudinal, in vivo, multiscale study in mice10.1302/2046-3758.92.BJR-2019-0161 ↗
15. Yin, X., Li, J., Hoffmann, W., Gasser, A., Brunski, J.B., and Helms, J.A. (2019). Mechanical and Biological Advantages of a Tri-Oval Implant Design. J. Clin. Med., 8.10.3390/jcm8040427 ↗
16. The effect of triangular cross-section neck design on crestal bone stability in the anterior mandible: A randomized, controlled, split-mouth clinical trial10.1111/clr.13821 ↗
17. Clinical and radiographic assessment of circular versus triangular cross-section neck Implants in the posterior maxilla: A 1-year randomized controlled trial10.1111/clr.13624 ↗
18. Fabbri, G., Staas, T., and Urban, I. (2022). A Retrospective Observational Study Assessing the Clinical Outcomes of a Novel Implant System with Low-Speed Site Preparation Protocol and Tri-Oval Implant Geometry. J. Clin. Med., 11.10.3390/jcm11164859 ↗
19. Li, J., Jansen, J.A., Walboomers, X.F., and van den Beucken, J.J. (2020). Mechanical aspects of dental implants and osseointegration: A narrative review. J. Mech. Behav. Biomed. Mater., 103.10.1016/j.jmbbm.2019.103574 ↗
20. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
21. Bone’s mechanostat: A 2003 update10.1002/ar.a.10119 ↗
22. Activation of resorption in fatigue-loaded bone involves both apoptosis and active pro-osteoclastogenic signaling by distinct osteocyte populations10.1016/j.bone.2012.01.025 ↗
23. The implant thread as a retention element in cortical bone: The effect of thread size and thread profile: A finite element study10.1016/S0021-9290(03)00164-7 ↗
24. The different contributions of cortical and trabecular bone to implant anchorage in a human vertebra10.1016/j.bone.2011.11.027 ↗
25. Effects of dental implant diameter and tapered body design on stress distribution in rigid polyurethane foam during insertion10.1016/j.medengphy.2024.104181 ↗
26. Relationship Between Primary/Mechanical and Secondary/Biological Implant Stability10.11607/jomi.19suppl.g1 ↗
27. Schulz, A., Klär, V., Grobecker-Karl, T., and Karl, M. (2023). Biomechanical rationale for a novel implant design reducing stress on buccal bone. Appl. Sci., 13.10.3390/app13010666 ↗
28. Klär, V., Zimmerer, R., Schulz, A., and Lethaus, B. (2023). Biomechanical performance of a novel implant design in simulated extraction sites and sinuslift procedures. Appl. Sci., 13.10.3390/app13137541 ↗
29. The Aachen Minipig: Phenotype, Genotype, Hematological and Biochemical Characterization, and Comparison to the Göttingen Minipig10.1159/000471483 ↗
30. Comparison of extraction sites versus artificial defects with xenogenic bone substitute in minipigs10.1002/cre2.390 ↗
31. Vertical osteoconductive characteristics of titanium implants with calcium-phosphate-coated surfaces—A pilot study in rabbits10.1111/j.1708-8208.2012.00469.x ↗
32. Early outcome of an implant system with a resorbable adhesive calcium-phosphate coating—A prospective clinical study in partially dentate patients10.1007/s00784-011-0598-8 ↗
33. A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique10.1111/j.1600-0714.1982.tb00172.x ↗
34. Biophysical regulation of osteotomy healing: An animal study10.1111/cid.12499 ↗
35. Occurrence of complications in patients restored with implants10.1111/clr.13970 ↗