Abstract

Cochlear implants are well established devices for treating severe hearing loss. However, due to the trauma caused by the insertion of the electrode and the subsequent formation of connective tissue, their clinical effectiveness varies. The aim of the current study was to achieve a long-term reduction in connective tissue growth and impedance by combining surface patterns on the electrode array with a poly-L-lactide coating containing 20% diclofenac. Three groups of six guinea pigs each (control, structure, structure with diclofenac in the coating) were implanted for four weeks. The hearing thresholds were measured before implantation and after 28 days, and impedances were monitored over time. After histological preparation, connective tissue growth and spiral ganglion neuron (SGN) survival were quantified. The hearing thresholds and impedances increased over time in all groups, showing no significant differences. The treatment groups showed increased damage in the cochlea, which appeared to be caused by the elevated parts of the microstructures. This seems to be amplified by the trauma model used in the current study. The impedances correlated with connective tissue growth near the electrode contacts. In addition, SGN survival was negatively correlated with the presence of connective tissue, both of which highlight the importance of successfully reducing connective tissue formation after cochlear implantation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hearing Loss and Rehabilitation · Hearing, Cochlea, Tinnitus, Genetics · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Otorhinolaryngology, Hannover Medical School, 30625 Hannover, Germany

Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, 30625 Hannover, Germany

Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany

MED-EL Medical Electronics, 6020 Innsbruck, Austria

Hearing4all Cluster of Excellence, Hannover Medical School, 30625 Hannover, Germany

Funding

BMBF RESPONSE FKZ

References (47)

Show source-provided references
1. Relationships between Intrascalar Tissue, Neuron Survival, and Cochlear Implant Function10.1007/s10162-020-00761-4 ↗
2. Preservation of Cells of the Organ of Corti and Innervating Dendritic Processes Following Cochlear Implantation in the Human: An Immunohistochemical Study10.1097/MAO.0000000000001686 ↗
3. Chronic Electrical Stimulation of the Auditory Nerve at High Stimulus Rates: A Physiological and Histopathological Study10.1016/S0378-5955(96)00193-1 ↗
4. Wilk, M., Hessler, R., Mugridge, K., Jolly, C., Fehr, M., Lenarz, T., and Scheper, V. (2016). Impedance Changes and Fibrous Tissue Growth after Cochlear Implantation Are Correlated and Can Be Reduced Using a Dexamethasone Eluting Electrode. PLoS ONE, 11.10.1371/journal.pone.0147552 ↗
5. Relations between Cochlear Histopathology and Hearing Loss in Experimental Cochlear Implantation10.1016/j.heares.2013.01.012 ↗
6. Quantitative Evaluation of New Bone and Fibrous Tissue in the Cochlea Following Cochlear Implantation in the Human10.1159/000103208 ↗
7. Histopathologic Assessment of Fibrosis and New Bone Formation in Implanted Human Temporal Bones Using 3D Reconstruction10.1016/j.otohns.2009.03.031 ↗
8. Hrnčiřík, F., Nagy, L., Grimes, H.L., Iftikhar, H., Muzaffar, J., and Bance, M. (2024). Impact of Insertion Speed, Depth, and Robotic Assistance on Cochlear Implant Insertion Forces and Intracochlear Pressure: A Scoping Review. Sensors, 24.10.3390/s24113307 ↗
9. Cochlear Implantation via the Round Window Membrane Minimizes Trauma to Cochlear Structures: A Histologically Controlled Insertion Study10.1080/00016480410018179 ↗
10. Considerations for the Design of Future Cochlear Implant Electrode Arrays: Electrode Array Stiffness, Size and Depth of Insertion10.1682/JRRD.2007.08.0119 ↗
11. Dexamethasone Eluting Cochlear Implant: Histological Study in Animal Model10.1179/1754762811Y.0000000024 ↗
12. A Single Intratympanic Triamcinolone Acetonide Administration Elicits Long-Term Reduction in Impedances Following Cochlear Implantation10.1177/19160216241288819 ↗
13. Development of a Safe Dexamethasone-Eluting Electrode Array for Cochlear Implantation10.1179/1754762813Y.0000000054 ↗
14. Comparison of Electrode Impedance Measures between a Dexamethasone-Eluting and Standard CochlearTM Contour Advance® Electrode in Adult Cochlear Implant Recipients10.1016/j.heares.2020.107924 ↗
15. Antiproliferative Effects of Aspirin and Diclofenac against the Growth of Cancer and Fibroblast Cells: In Vitro Comparative Study10.1016/j.jsps.2015.01.002 ↗
16. “Smart Tattoo” Glucose Biosensors and Effect of Coencapsulated Anti-Inflammatory Agents10.1177/193229681100500111 ↗
17. Wulf, K., Goblet, M., Raggl, S., Teske, M., Eickner, T., Lenarz, T., Grabow, N., and Paasche, G. (2022). PLLA Coating of Active Implants for Dual Drug Release. Molecules, 27.10.3390/molecules27041417 ↗
18. Behrends, W., Wulf, K., Raggl, S., Fröhlich, M., Eickner, T., Dohr, D., Esser, K.-H., Lenarz, T., Scheper, V., and Paasche, G. (2023). Dual Drug Delivery in Cochlear Implants: In Vivo Study of Dexamethasone Combined with Diclofenac or Immunophilin Inhibitor MM284 in Guinea Pigs. Pharmaceutics, 15.10.3390/pharmaceutics15030726 ↗
19. Local Drug Delivery to Conserve Hearing: Mechanisms of Action of Eluted Dexamethasone within the Cochlea10.1179/146701011X13001035753254 ↗
20. Cochlear Implant Surgery Facilitates Intracochlear Distribution of Perioperative Systemic Steroids10.1080/00016489.2023.2241877 ↗
21. Intracochlear Drug Delivery Systems10.1517/17425247.2011.588207 ↗
22. Distribution of Dexamethasone and Preservation of Inner Ear Function Following Intratympanic Delivery of a Gel-Based Formulation10.1159/000322504 ↗
23. Hearing Protection Outcomes of Analog Electrode Arrays Coated with Different Drug-Eluting Polymer Films Implanted into Guinea Pig Cochleae10.2147/DDDT.S318117 ↗
24. Development of a Specially Tailored Local Drug Delivery System for the Prevention of Fibrosis after Insertion of Cochlear Implants into the Inner Ear10.1007/s10856-012-4698-z ↗
25. Biodegradable Polymeric Coatings on Cochlear Implant Surfaces and Their Influence on Spiral Ganglion Cell Survival10.1002/jbm.b.33110 ↗
26. Dohr, D., Wulf, K., Grabow, N., Mlynski, R., and Schraven, S.P. (2022). A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds. Materials, 15.10.1055/s-0042-1746741 ↗
27. Biodegradable Polymer Drug-Eluting Stents Reduce the Risk of Stent Thrombosis at 4 Years in Patients Undergoing Percutaneous Coronary Intervention: A Pooled Analysis of Individual Patient Data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS Randomized Trials10.1093/eurheartj/ehs086 ↗
28. Role of the Cytoskeleton in the Reaction of Fibroblasts to Multiple Grooved Substrata10.1002/cm.970310207 ↗
29. Cell-Shape Regulation of Smooth Muscle Cell Proliferation10.1016/j.bpj.2008.11.074 ↗
30. Influence of Silicone (PDMS) Surface Texture on Human Skin Fibroblast Proliferation as Determined by Cell Cycle Analysis10.1002/(SICI)1097-4636(199821)43:1<1::AID-JBM1>3.0.CO;2-T ↗
31. Chronic Electrical Stimulation of the Auditory Nerve Using High Surface Area (HiQ) Platinum Electrodes10.1016/S0378-5955(01)00320-3 ↗
32. Electrical stimulation of the guinea pig cochlea10.1177/019459988709600408 ↗
33. Three-Dimensional Imaging of the Intact Mouse Cochlea by Fluorescent Laser Scanning Confocal Microscopy10.1016/j.heares.2008.05.009 ↗
34. Spiral Ganglion Neuron Quantification in the Guinea Pig Cochlea Using Confocal Laser Scanning Microscopy Compared to Embedding Methods10.1016/j.heares.2013.08.002 ↗
35. Electrode Array-Eluted Dexamethasone Protects against Electrode Insertion Trauma Induced Hearing and Hair Cell Losses, Damage to Neural Elements, Increases in Impedance and Fibrosis: A Dose Response Study10.1016/j.heares.2016.02.003 ↗
36. Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma10.1097/AUD.0000000000000394 ↗
37. Evaluation of Insertion Forces and Cochlea Trauma Following Robotics-Assisted Cochlear Implant Electrode Array Insertion10.1097/MAO.0000000000002608 ↗
38. Dry Friction of Microstructured Polymer Surfaces Inspired by Snake Skin10.3762/bjnano.5.122 ↗
39. Tomanik, M., Kobielarz, M., Filipiak, J., Szymonowicz, M., Rusak, A., Mroczkowska, K., Antończak, A., and Pezowicz, C. (2020). Laser Texturing as a Way of Influencing the Micromechanical and Biological Properties of the Poly(L-Lactide) Surface. Materials, 13.10.3390/ma13173786 ↗
40. Surgery of the Inner Ear With Hearing Preservation: Serial Histological Changes10.1097/00005537-200309000-00003 ↗
41. Simoni, E., Gentilin, E., Candito, M., Borile, G., Romanato, F., Chicca, M., Nordio, S., Aspidistria, M., Martini, A., and Cazzador, D. (2020). Immune Response After Cochlear Implantation. Front. Neurol., 11.10.3389/fneur.2020.00341 ↗
42. Impact of Intrascalar Blood on Hearing10.1097/01.mlg.0000242073.02488.f4 ↗
43. Foreign Body Response to Silicone in Cochlear Implant Electrodes in the Human10.1097/MAO.0000000000001454 ↗
44. Foreign Body Reaction to Biomaterials10.1016/j.smim.2007.11.004 ↗
45. Multinucleated Giant Cells in the Implant Bed of Bone Substitutes Are Foreign Body Giant Cells—New Insights into the Material-mediated Healing Process10.1002/jbm.a.36006 ↗
46. Photocured Biodegradable Polymer Substrates of Varying Stiffness and Microgroove Dimensions for Promoting Nerve Cell Guidance and Differentiation10.1021/la302868q ↗
47. Noise Exposure of the Inner Ear During Drilling a Cochleostomy for Cochlear Implantation10.1097/MLG.0b013e31802f4169 ↗