journal article·2024-09-14Open access

Stress Distribution of Pediatric Zirconia and Stainless Steel Crowns after Pulpotomy Procedure under Vertical Loading: A Patient-Specific Finite Element Analysis

Özgür Doğan

Abstract

Aim: With modern dentistry advancements, children and parents have significantly raised aesthetic expectations in pediatric dentistry. Pediatric zirconia crowns (PZCs) provide a superior aesthetic appearance compared with stainless steel crowns (SSCs), making them a popular treatment option. However, a comparison of the compressive stresses caused by these crowns on the roots of primary teeth and alveolar bones has not been conducted. Materials and Methods: Cone beam computed tomography (CBCT) images of an eight-year-old female patient who experienced premature loss of a primary mandibular left second molar were obtained from a dental hospital database. Rhinoceros 4.0 software was used to process and simulate images. Under simulated chewing forces, stress on the PZC, SSC, and intact primary first molars as control groups, as well as their roots and alveolar bone structures, was assessed with finite element analysis. Statistical Analyses: Depending on whether the descriptive data were normally distributed, the Student t-test and Mann–Whitney U test were used. Quantitative variables differ between the two categories of qualitative variables. One-way ANOVA and Kruskal–Wallis H tests were used depending on standard distribution assumptions. p < 0.05 indicates statistical significance differences. Results: PZCs, SSCs, and cement layers were stressed according to von Mises values, while roots and alveolar bones were stressed according to maximum and minimum stress values. When assessing crowns, SSCs exhibited the highest von Mises stress values, followed by PZCs and control groups (p < 0.001). In the cement layer, SSCs obtained significantly higher values (p = 0.003). In the root area, minimum principal stress values are more critical. The highest values were obtained from the intact tooth, PZC, and SSC, respectively (p < 0.001). Alveolar bones did not differ significantly in minimum principal stress (p = 0.950). Conclusions: Restorative full-coverage crowns exhibited higher von Mises values than intact teeth, as per current research findings. The von Mises values were highest in SSC, while lowest in PZC. As a result of this condition, the cement layer and root areas had higher von Mises stress and compressive stress. Alveolar bones were not affected regardless of restoration type. PZC transmits higher stress due to its properties.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental materials and restorations · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Pediatric Dentistry, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar 03030, Turkey

Funding

Afyonkarahisar Health Science University Scientific Research Projects Coordinatorship

References (49)

Show source-provided references
1. Evaluation of the Clinical Performance of NuSmile Pedodontics Zirconia Crowns in Pulp-Treated Primary Teeth—2 Years Follow-Up Study
2. A randomised controlled trial of three aesthetic full-coronal restorations in primary maxillary teeth
3. Zirconia crowns for children: A systematic review10.1111/ipd.12793 ↗
4. Effectiveness of zirconia crowns compared with stainless steel crowns in primary posterior teeth rehabilitation10.1016/j.adaj.2021.08.005 ↗
5. Use of Restorative Full Crowns Made with Zirconia in Children: A Systematic Review10.5005/jp-journals-10005-1822 ↗
6. The Clinical Success of Zirconia-Based Crowns: A Systematic Review10.11607/ijp.3647 ↗
7. Arm design of band and loop space maintainer affects its longevity: A patient-specific finite element study10.22514/jocpd.2024.019 ↗
8. Protective potential of different mouthguard thicknesses against perianaesthetic dental specific-finite element study
9. Mouthguard use and TMJ injury prevention with different occlusions: A three-dimensional finite element analysis10.1111/edt.12577 ↗
10. Influence of ceramic veneer thickness and antagonist on impact stresses during dental trauma with and without a mouthguard assessed with finite element analysis
11. The use of stainless steel crowns: A systematic literature review
12. Geduk, N., Ozdemir, M., Unverdi, G.E., Ballikaya, E., and Cehreli, Z.C. (2023). Clinical and radiographic performance of preformed zirconia crowns and stainless-steel crowns in permanent first molars: 18-month results of a prospective, randomized trial. BMC Oral Health, 23.10.1186/s12903-023-03501-1 ↗
13. Evaluation of clinical success, parental and child satisfaction of stainless steel crowns and zirconia crowns in primary molars10.4103/jfmpc.jfmpc_1006_19 ↗
14. Comparison of periodontal health of primary teeth restored with zirconia and stainless steel crowns: A systemic review and meta-analysis10.1016/j.jfma.2022.08.015 ↗
15. American Academy of Pediatric Dentistry (2012). Clinical Affairs Committee—Restorative Dentistry Subcommittee. Guideline on pediatric restorative dentistry. Pediatr. Dent., 34, 173–180.
16. UK National Clinical Guidelines in Paediatric Dentistry: Stainless steel preformed crowns for primary molars10.1111/j.1365-263X.2008.00935.x ↗
17. Primary pulpotomies—What should we be using?10.1038/s41432-022-0840-z ↗
18. Direct Pulp Capping of Primary Molars with Calcium Hydroxide or MTA Following Hemorrhage Control with Different Medicaments: Randomized Clinical Trial
19. Effectiveness of full Pulpotomy compared with Root canal treatment in managing teeth with signs and symptOms indicative of irreversible pulpitis: A protocol for prospectiVE meta-analysis of individual participant data of linked randomised clinical trials (PROVE)10.1186/s13063-023-07836-6 ↗
20. Clinical and radiographic effectiveness of mineral trioxide aggregate (MTA) partial pulpotomy with low power or high power diode laser irradiation in deciduous molars: A randomized clinical trial10.1007/s10103-022-03503-5 ↗
21. Assessment of Clinical and Radiographic Success Rate of Formocresol-based Pulpotomy versus Collagen-based Pulpotomy: An In Vivo Study10.5005/jp-journals-10024-3117 ↗
22. Effects of Root Maturation and Thickness Variation in Coronal Mineral Trioxide Aggregate Plugs Under Traumatic Load on Stress Distribution in Regenerative Endodontic Procedures: A 3-dimensional Finite Element Analysis Study10.1016/j.joen.2020.11.006 ↗
23. Are Increased Masticatory Forces Risk for Primary 2nd Molars without Successors? A 3D FEA Study10.17796/1053-4625-43.1.12 ↗
24. Influence of different ethylene-vinyl acetate brands used for custom-fitted mouthguard fabrication on the stress and strain during an impact10.1111/edt.12746 ↗
25. Influence of mouthguards and their palatal design on the stress-state of tooth-periodontal ligament-bone complex under static loading10.1111/edt.12386 ↗
26. Finite element stress analysis of restored primary teeth: A comparative evaluation between stainless steel crowns and preformed zirconia crowns10.4103/ijohs.ijohs_18_17 ↗
27. Effect of Root Filling on Stress Distribution in Premolars with Endodontic-Periodontal Lesion: A Finite Elemental Analysis Study10.1016/j.joen.2015.09.010 ↗
28. Guler, M.S., Guler, C., Kara, N.B., Odabasi, D., and Bekci, M.L. (2024). The stress distribution of a primary molar tooth restored with stainless steel crown using different luting cements. BMC Oral Health, 24.10.1186/s12903-024-04038-7 ↗
29. Chung, S.-Y., Lee, H., Chae, Y.K., Jung, Y.S., Jo, S.-S., Lee, K.E., Choi, S.C., and Nam, O.H. (2022). Stress distribution in pediatric zirconia crowns depending on different tooth preparation and cement type: A finite element analysis. BMC Oral Health, 22.10.1186/s12903-022-02596-2 ↗
30. Evaluation of Fracture Strength after Repair of Cervical External Resorption Cavities with Different Materials10.1016/j.joen.2023.10.007 ↗
31. (2024, September 02). NuSmile® Pre Contoured SSC Instruction for Use. Available online: https://www.flipsnack.com/6C989CDD75E/ifu-35-nusmile-ssc-instructions-for-use-multi-lang-rev-5/full-view.html.
32. Comparison of Amount of Primary Tooth Reduction Required for Anterior and Posterior Zirconia and Stainless Steel Crowns
33. (2024, September 02). NuSmile® Zirconia Instructions for Use and General Information. Available online: https://www.flipsnack.com/6C989CDD75E/ifu-05-zr-technical-guide-eng-rev-13/full-view.html.
34. Evaluation of the fracture resistance of computer-aided design/computer-aided manufacturing monolithic crowns prepared in different cement thicknesses10.4103/njcp.njcp_137_17 ↗
35. Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: A finite element analysis study10.1016/j.prosdent.2020.08.042 ↗
36. Maximum equivalent stress induced and the displacement of the developing permanent first molars after the premature loss of primary second molars: A finite element analysis10.17219/dmp/122041 ↗
37. Is zirconium or stainless steel the most suitable crown material for less dentin stress in endodontically treated teeth?10.3233/THC-213505 ↗
38. The effect of occlusal loading on cervical gap deformation: A 3D finite element analysis10.1016/j.dental.2020.03.008 ↗
39. Maximum occusal bite force for children in different dentition stages10.1093/ejo/cjs021 ↗
40. Pediatric Stainless-Steel Crown Cementation Finite Element Study
41. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials10.1155/2017/1029574 ↗
42. Clinical effectiveness of restorative materials for the restoration of carious lesions in pulp treated primary teeth: A systematic review10.1007/s40368-022-00744-4 ↗
43. Stanley, J.N. (2010). AMM. Wheeler’s Dental Anatomy, Physiology and Occlusion, Elsevier.
44. Hall versus conventional stainless steel crown techniques: In vitro investigation of marginal fit and microleakage using three different luting agents
45. Bite force determination in children with primary dentition10.1046/j.1365-2842.2002.00957.x ↗
46. Finite Element Stress Analysis of Stainless Steel Crowns
47. European Commission (2015). Medical Radiation Exposure of the European Population, Publications Office of the European Union. Available online: https://data.europa.eu/doi/10.2833/708119.
48. Endocrown Feasibility for Primary Molars: A Finite Element Study
49. Effect of Crown Preparation Height on Retention of a Prefabricated Primary Posterior Zirconia Crown