journal article·2025-10-02Open access

Stress Assessment of Abutment-Free and Three Implant–Abutment Connections Utilizing Various Abutment Materials: A 3D Finite Element Study of Static and Cyclic Static Loading Conditions

Maryam H. Mugri, Nandalur Kulashekar Reddy, Mohammed E. Sayed, Khurshid Mattoo, Osama Mohammed Qomari, Mousa Mahmoud Alnaji, Waleed Abdu Mshari, Firas K. Alqarawi, Saad Saleh AlResayes, Raghdah M. Alshaibani

Journal of Functional Biomaterials· Volume 16· Issue 10

Abstract

Background: The implant–abutment interface has been thoroughly examined due to its impact on the success of implant healing and longevity. Removing the abutment is advantageous, but it changes the biomechanics of the implant fixture and restoration. This in vitro three-dimensional finite element analytical (FEA) study aims to evaluate the distribution of von Mises stress (VMS) in abutment-free and three additional implant abutment connections composed of various titanium alloys. Materials and methods: A three-dimensional implant-supported single-crown prosthesis model was digitally generated on the mandibular section using a combination of microcomputed tomography imaging (microCT), a computer-assisted designing (CAD) program (SolidWorks), Analysis of Systems (ANSYS), and a 3D digital scan (Visual Computing Lab). Four digital models [A (BioHorizons), B (Straumann AG), C abutment-free (Matrix), and D (TRI)] representing three different functional biomaterials [wrought Ti-6Al-4Va ELI, Roxolid (85% Ti, 15% Zr), and Ti-6Al-4V ELI] were subjected to simulated static/cyclic static loading in axial/oblique directions after being restored with highly translucent monolithic zirconia restoration. The stresses generated on the implant fixture, abutment, crown, screw, cortical, and cancellous bones were measured. Results: The highest VMSs were generated by the abutment-free (Model C, Matrix) implant system on the implant fixture [static (32.36 Mpa), cyclic static (83.34 Mpa)], screw [static (16.85 Mpa), cyclic static (30.33 Mpa), oblique (57.46 Mpa)], and cortical bone [static (26.55), cyclic static (108.99 Mpa), oblique (47.8 Mpa)]. The lowest VMSs in the implant fixture, abutment, screw, and crown were associated with the binary alloy Roxolid [83–87% Ti and 13–17% Zr]. Conclusions: Abutment-free implant systems generate twice the stress on cortical bone than other abutment implant systems while producing the highest stresses on the fixture and screw, therefore demanding further clinical investigations. Roxolid, a binary alloy of titanium and zirconia, showed the least overall stresses in different loadings and directions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

Intern Clinic, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia

Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 12372, Saudi Arabia

Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh 11671, Saudi Arabia

References (64)

Show source-provided references
1. Functionally graded bi-omimetic biomaterials in dentistry: An evidence-based update10.1080/09205063.2020.1744289 ↗
2. An 2/2 implant overdenture10.33309/2639-8281.030102 ↗
3. Mechanical behavior of titanium and zirconia abutments at the implant-abutment interface: A systematic review10.1016/j.prosdent.2022.01.006 ↗
4. Microleakage along the implant–abutment interface: A systematic review and meta-analysis of in vitro studies10.1186/s40729-023-00494-y ↗
5. A study of 42 partially edentulous patients with single-crown restorations and implants to compare bone loss between crestal and subcrestal endosseous implant placement
6. Fretting-corrosion at the Implant–Abutment Interface Simulating Clinically Relevant Conditions10.1016/j.dental.2024.08.007 ↗
7. Implant-Abutment Connections: A Review of Biologic Consequences and Peri-implantitis Implications10.11607/jomi.5732 ↗
8. Influence of implant–abutment connection biomechanics on biological response: A literature review on interfaces between implants and abutments of titanium and zirconia10.3390/prosthesis5020036 ↗
9. Current complications and issues of implant superstructure10.2334/josnusd.21-0534 ↗
10. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: A short communication10.1111/j.1365-2842.2006.01545.x ↗
11. A finite element analysis of two different dental implants: Stress distribution in the prosthesis, abutment, implant, and supporting bone10.1563/1548-1336(2008)34[1:AFEAOT]2.0.CO;2 ↗
12. Biomechanical factors that influence the bone-implant-interface
13. Evaluation of stress distribution in and around dental implants using three different implant–abutment interfaces with platform-switched and non-platform-switched abutments: A three-dimensional finite element analysis10.34172/joddd.2023.40723 ↗
14. The effect of dental implant length and diameter on the stress distribution at the implant-bone interface of the immediate loading implants: A 3/D finite element analysis10.33899/rden.2012.84678 ↗
15. The influence of various occlusal materials on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite-element study10.1002/jbm.b.30191 ↗
16. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses10.1016/j.jfma.2016.01.002 ↗
17. Fem and von Mises analysis of OSSTEM dental implant structural components: Evaluation of different direction dynamic loads10.2174/1874210601812010219 ↗
18. Influence of different abutment designs on the biomechanical behavior of one-piece zirconia dental implants and their surrounding bone: A 3D-FEA10.1016/j.irbm.2019.07.001 ↗
19. Comparing one-and two-piece dental abutments under dynamic loading: A 3-D finite element analysis10.21817/ijet/2019/v11i6/191106092 ↗
20. Barbosa, F.T., Zanatta, L.C.S., de SouzaRendohl, E., and Gehrke, S.A. (2021). Comparative analysis of stress distribution in one-piece and two-piece implants with narrow and extra- narrow diameters: A finite element study. PLoS ONE, 16.10.1371/journal.pone.0245800 ↗
21. Stress evaluation of implant-abutment connections under different loading conditions: A 3D finite element study10.1563/AAID-JOI-D-11-00205 ↗
22. Mechanical stability of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns10.11607/jomi.7431 ↗
23. In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores10.11607/jomi.2772 ↗
24. Effects of two fretting damage modes on the dental implant–abutment interface and the generation of metal wear debris: An in vitro study10.1111/ffe.13399 ↗
25. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study10.1016/j.prosdent.2017.03.008 ↗
26. Talmazov, G., Veilleux, N., Abdulmajeed, A., and Bencharit, S. (2020). Finite element analysis of a one-piece zirconia implant in anterior single tooth implant applications. PLoS ONE, 15.10.1371/journal.pone.0229360 ↗
27. Finite element analysis of zirconia dental implant10.3390/prosthesis4030040 ↗
28. Deste Gökay, G., Oyar, P., Gökçimen, G., and Durkan, R. (2024). Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: A 3D finite element analysis. BMC Oral Health, 24.10.1186/s12903-024-04328-0 ↗
29. Three generations of zirconia: From veneered to monolithic
30. (2025, August 29). TRI Dental Implants. Available online: https://tri-implants.swiss/en/matrix-line/.
31. (2025, August 29). TRI Dental Implants. Available online: https://tri-implants.swiss/en/performance-line/.
32. A New Implant System with Directly Screwed Supraconstructions: Impact of Restoration Material and Artificial Aging on the Bending Moment10.11607/ijp.8102 ↗
33. Lee, J.H., Jang, H.Y., and Lee, S.Y. (2021). Finite element analysis of dental implants with zirconia crown restorations: Conventional cement-retained vs. cementless screw-retained. Materials, 14.10.3390/ma14102666 ↗
34. Brizuela-Velasco, A., Pérez-Pevida, E., Jiménez-Garrudo, A., Gil-Mur, F.J., Manero, J.M., Punset-Fuste, M., Chávarri-Prado, D., Diéguez-Pereira, M., and Monticelli, F. (2017). Mechanical characterisation and biomechanical and biological behaviours of Ti-Zr binary-alloy dental implants. BioMed Res. Int., 2017.10.1155/2017/2785863 ↗
35. Micronucleus assay assessment of possible genotoxic effects in patients treated with titanium alloy endosseous implants or miniplates10.1016/j.mrgentox.2013.10.005 ↗
36. A critical review of dental implant materials with an emphasis on titanium versus zirconia10.3390/ma8030932 ↗
37. (2025, August 29). Bio-Horizon Tapered Pro Conical Implant. Available online: https://www.biohorizons.com/products/TaperedProConical.
38. Microstructure and mechanical properties of Titanium grade 23 produced by selective laser melting10.1007/s43452-021-00304-5 ↗
39. Shemtov-Yona, K. (2021). Quantitative assessment of the jawbone quality classification: A meta-analysis study. PLoS ONE, 16.10.1371/journal.pone.0253283 ↗
40. (2025, August 29). Straumann Roxolid. Available online: https://www.straumann.com/en/dental-professionals/dental-implants/dental-implant-materials/roxolid.html.
41. Micro-CT Evaluation of Root and Canal Morphology of Mandibular First Premolars with Radicular Grooves10.1590/0103-6440201601784 ↗
42. Dynamic Loading Test for Endosseous Dental Implants (Shenzhen, China) (Standard No. ISO 14801). Available online: https://www.mts.com/en/applications/materials/test-standard/iso/iso-14801.
43. Preload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw: An in vitro study10.1186/s40729-023-00473-3 ↗
44. 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study10.1034/j.1600-0501.1996.070413.x ↗
45. Farooq, M., and Sazonov, E. (2016). Automatic Measurement of Chew Count and Chewing Rate during Food Intake. Electronics, 5.10.3390/electronics5040062 ↗
46. Fatigue and biological properties of Ti-6Al-4V ELI cellular structures with variously arranged cubic cells made by selective laser melting10.1016/j.jmbbm.2017.11.044 ↗
47. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface10.1016/j.jdent.2022.104121 ↗
48. Clinical Evaluation of the Influence of Connection Type and Restoration Height on the Reliability of Zirconia Abutments: A Retrospective Study on 965 Abutments with a Mean 6-Year Follow-Up10.11607/prd.2974 ↗
49. Three-dimensional finite element analysis of the biomechanical behaviour of different dental implants under immediate loading during three masticatory cycles
50. Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: A finite element analysis study10.1016/j.prosdent.2020.08.042 ↗
51. Screw retained vs. cement retained implant-supported fixed dental prosthesis10.1111/prd.12168 ↗
52. Cho, S.M., Byun, S.H., Ahn, S.Y., Han, H.S., On, S.W., Park, S.Y., Yi, S.M., Park, I.Y., Yang, B.E., and Kim, L.K. (2025). Biomechanical Evaluation of a Novel Non-Engaging Abutment and Screw in Internal Implant Systems: Comparative Fatigue and Load Testing. J. Funct. Biomater., 16.10.3390/jfb16030107 ↗
53. Three dimensional finite element analysis of stress distribution around implant with straight and angled abutments in different bone qualities10.1007/s13191-012-0242-6 ↗
54. Effect of implant placement depth on bone remodeling on implant-supported single zirconia abutment crown: A 3D finite element study10.2186/jpr.JPR_D_22_00054 ↗
55. Finite element analysis of dental implants with and without microthreads under static and dynamic loading10.1615/JLongTermEffMedImplants.2017020007 ↗
56. Pirmoradian, M., Naeeni, H.A., Firouzbakht, M., Toghraie, D., Khabaz, M.K., and Darabi, R. (2020). Finite element analysis and experimental evaluation on stress distribution and sensitivity of dental implants to assess optimum length and thread pitch. Comput. Methods Programs Biomed., 187.10.1016/j.cmpb.2019.105258 ↗
57. High-Stress Compressive Creep Behavior of Ti-6Al-4V ELI Alloys with Different Microstructures10.1051/matecconf/202032111007 ↗
58. Microstructural Heterogeneity and Anisotropic Mechanical Properties of Titanium alloys manufactured by Wire Arc Additive Manufacturing: A review
59. Additive manufacturing of titanium-based alloys-A review of methods, properties, challenges, and prospects10.1016/j.heliyon.2022.e09041 ↗
60. Effect of alloying elements on the compressive mechanical properties of biomedical titanium alloys: A systematic review10.1021/acsomega.2c02096 ↗
61. The effects of design parameters on mechanical failure of Ti-6Al-4V implants using finite element analysis10.1016/j.engfailanal.2020.104445 ↗
62. Designing the occlusion for a single tooth implant in a compromised occlusion
63. Influence of prosthodontic rehabilitation using zygomatic implants in Covid 19 related mucormycosis (rhino–orbital–cerebral) maxillectomy patients upon post-operative stress, anxiety and functional impairment: A prospective cohort study10.2147/CIA.S412625 ↗
64. Prosthodontic rehabilitation’s role in alleviating anxiety and depression in mucormycosis-induced maxillectomy patients post-COVID-1910.12659/MSM.941488 ↗