Abstract

The purpose of this finite element analysis (FEA) was to evaluate the stress distribution within the prosthetic components and bone in relation to varying cement thicknesses (from 20 to 60 μm) utilized to attach a zirconia crown on a conometric cap. The study focused on two types of implants (Cyroth and TAC, AoN Implants, Grisignano di Zocco, Italy) featuring a Morse cone connection. Detailed three-dimensional (3D) models were developed to represent the bone structure (cortical and trabecular) and the prosthetic components, including the crown, cement, cap, abutment, and the implant. Both implants were placed 1.5 mm subcrestally and subjected to a 200 N load at a 45° inclination on the crown. The results indicated that an increase in cement thickness led to a reduction in von Mises stress on the cortical bone for both Cyroth and TAC implants, while the decrease in stress on the trabecular bone (apical zone) was relatively less pronounced. However, the TAC implant exhibited a higher stress field in the apical area compared to the Cyroth implant. In summary, this study investigated the influence of cement thickness on stress transmission across prosthetic components and peri-implant tissues through FEA analysis, emphasizing that the 60 μm cement layer demonstrated higher stress values approaching the material strength limit.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy

Department of Medical, Oral and Biotechnological Sciences, “G. D’Annunzio” University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy

Center for Advanced Studies and Technology (CAST), “G. D’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy

Independent Researcher, 31020 San Vendemiano, Italy

Independent Researcher, 92019 Sciacca, Italy

School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy

Facultad de Medicina, UCAM Universidad Católica San Antonio de Murcia, 30107 Murcia, Spain

Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy

References (63)

Show source-provided references
1. From porcelain-fused-to-metal to zirconia: Clinical and experimental considerations10.1016/j.dental.2010.10.024 ↗
2. Influence of crown design and material on chipping resistance of all-ceramic molar crowns: An in vitro study10.17219/dmp/85000 ↗
3. Metal-free materials for fixed prosthodontic restorations
4. Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses10.1016/j.dental.2011.09.012 ↗
5. Has zirconia made a material difference in implant prosthodontics? A review10.1016/j.dental.2019.08.100 ↗
6. In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness10.1016/j.jmbbm.2016.04.014 ↗
7. CAD/CAM-fabricated implant-supported restorations: A systematic review10.1111/clr.12633 ↗
8. Incidence of undetected cement on CAD/CAM monolithic zirconia crowns and customized CAD/CAM implant abutments. A prospective case series10.1111/clr.12879 ↗
9. Clinical performance of screw-versus cement-retained fixed implantsupported reconstructions—A systematic review10.11607/jomi.2014suppl.g2.1 ↗
10. A Systematic Review of Screw versus Cement-Retained Fixed Implant Supported Reconstructions10.2147/CCIDE.S231070 ↗
11. A comparison between screw-and cement-retained implant prostheses. A literature review10.1563/AAID-JOI-D-10-00146 ↗
12. Cemented and screw-retained implant reconstructions: A systematic review of the survival and complication rates10.1111/j.1600-0501.2012.02538.x ↗
13. Long-term outcome of cemented versus screwretained implant supported partial restorations
14. Cemented vs screw retained zirconiabased single implant reconstructions: A 3-year prospective randomized controlled clinical trial10.1111/cid.12735 ↗
15. Screw retained vs. cement retained implant-supported fixed dental prosthesis10.1111/prd.12168 ↗
16. Fracture resistance of implant-supported screw-versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis10.1016/j.dental.2005.10.013 ↗
17. Finite-Element Analysis Study Comparing Titanium and Polyetheretherketone Caps in a Conometric Connection between Implant and Prosthesis10.1002/adem.202400198 ↗
18. The Conometric Connection for the Implant-Supported Fixed Prosthesis: A Narrative Review10.3390/prosthesis4030037 ↗
19. Finite Element Analysis (FEA) for the Evaluation of Retention in a Conometric Connection for Implant and Prosthesis10.3390/osteology3040015 ↗
20. Guided-Welded Approach Planning Using a Computer-Aided Designed Prosthetic Shell for Immediately Loaded Complete-Arch Rehabilitations Supported by Conometric Abutments10.1016/j.prosdent.2018.12.002 ↗
21. CAD/CAM Conic Crowns for Predictable Retention in Implant-Supported Prostheses10.11607/ijp.4303 ↗
22. Computer-Aided Crown Design Using Digital Scanning Technology for Immediate Postextraction Single-Implant Restorations Supported by Conical Indexed Abutments
23. Effect of adhesive resin cements on bond strength of ceramic core materials to dentin10.4103/njcp.njcp_10_17 ↗
24. Simplified cementation of lithium disilicate crowns: Retention with various adhesive resin cement combinations10.1016/j.prosdent.2017.07.012 ↗
25. Dressano, D., Salvador, M.V., Oliveira, M.T., Marchi, G.M., Fronza, B.M., Hadis, M., Palin, W.M., and Lima, A.F. (2020). Chemistry of novel and contemporary resin-based dental adhesives. J. Mech. Behav. Biomed. Mater., 110.10.1016/j.jmbbm.2020.103875 ↗
26. The selection of adhesive systems for resin-based luting agents
27. Glass-ionomer cement origins, development and future10.1016/0267-6605(91)90070-V ↗
28. Properties of a proline-containing glass ionomer dental cement10.1016/j.prosdent.2013.04.009 ↗
29. The evaluation of microleakage and fluoride release of different types of glass ionomer cements10.4103/njcp.njcp_644_18 ↗
30. Glass ionomer restorative cement systems: An update
31. Self-adhesive Resin Cements: Characteristics, Properties, and Manipulation. AEGIS Dental Network
32. Self-Adhesive Resin Cements: A Clinical Review10.1111/jopr.12192 ↗
33. Self-adhesive resin cements: A new perspective in luting technology10.12968/denu.2013.40.9.758 ↗
34. Sorption and solubility characteristics of self-adhesive resin cements10.1016/j.dental.2012.04.037 ↗
35. Glass-ionomer cement restorative materials: A sticky subject?10.1111/j.1834-7819.2010.01293.x ↗
36. Retention Force of Glass Ionomer Based Luting Cements with Posterior Primary Zirconium Crowns—A Comparative in Vitro Study10.17796/1053-4625-45.4.7 ↗
37. The effect of luting cement type and thickness on stress distribution in upper premolar implant restored with metal ceramic crowns
38. Shillingburg, H.T., and Sather, D.A. (2012). Fundamentals of Fixed Prosthodontics, Quintessence Pub. [4th ed.].
39. Stress distribution in metal-ceramic crowns with a facial porcelain margin10.1177/00220345870660091601 ↗
40. Effects of labial margin design on stress distribution of a porcelain-fused-to-metal crown10.1111/j.1532-849X.1992.tb00421.x ↗
41. Degradability of dental ceramics10.1177/08959374920060012201 ↗
42. Di Pietro, N., Ceddia, M., Romasco, T., De Bortoli, J.N., Mello, B.F., Tumedei, M., Specchiulli, A., Piattelli, A., and Trentadue, B. (2023). Finite element analysis (FEA) of the stress and strain distribution in cone-morse implant–abutment connection implants placed equicrestally and subcrestally. Appl. Sci., 13.10.20944/preprints202306.1720.v1 ↗
43. Comuzzi, L., Ceddia, M., Di Pietro, N., Inchingolo, F., Inchingolo, A.M., Romasco, T., Tumedei, M., Specchiulli, A., Piattelli, A., and Trentadue, B. (2023). Crestal and Subcrestal Placement of Morse Cone Implant–Abutment Connection Implants: An In Vitro Finite Element Analysis (FEA) Study. Biomedicines, 11.10.3390/biomedicines11113077 ↗
44. Bone Mechanical Properties in Healthy and Diseased States10.1146/annurev-bioeng-062117-121139 ↗
45. Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions10.1016/j.medengphy.2005.06.003 ↗
46. Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement10.1016/S0278-2391(99)90437-8 ↗
47. Li, J., Jansen, J.A., Walboomers, X.F., and van den Beucken, J.J. (2020). Mechanical aspects of dental implants and osseointegration: A narrative review. J. Mech. Behav. Biomed. Mater., 103.10.1016/j.jmbbm.2019.103574 ↗
48. Interrelationships between densitometric, geometric, and mechanical properties of rat femora: Inferences concerning mechanical regulation of bone modeling10.1002/jbmr.5650081113 ↗
49. Influences of geometrical and mechanical properties of bone tissues in mandible behaviour–experimental and numerical predictions10.1080/10255842.2017.1322072 ↗
50. Influence of bone quality on the mechanical interaction between implant and bone: A finite element analysis10.1016/j.jdent.2019.06.008 ↗
51. Bond strength of zirconia- or polymer-based copings cemented on implant-supported titanium bases—An in vitro study
52. Ceddia, M., Lamberti, L., and Trentadue, B. (2024). FEA Comparison of the Mechanical Behavior of Three Dental Crown Materials: Enamel, Ceramic, and Zirconia. Materials, 17.10.3390/ma17030673 ↗
53. Mechanical properties of new self-adhesive resin-based cement10.1016/j.jpor.2009.09.004 ↗
54. Screw-versus cement-retained implant restorations: Current concepts10.1097/ID.0b013e3181bb9033 ↗
55. Endosseous implant failure influenced by crown cementation: A clinical case report
56. Screw versus cemented implant-supported restorations10.1038/sj.bdj.4814157 ↗
57. Cement-retained versus screw-retained implant restorations: A critical review
58. Lee, J.-H., Jang, H.Y., and Lee, S.Y. (2021). Finite Element Analysis of Dental Implants with Zirconia Crown Restorations: Conventional Cement-Retained vs. Cementless Screw-Retained. Materials, 14.10.3390/ma14102666 ↗
59. Vertical load distribution on a three-unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study10.1034/j.1600-0501.1995.060105.x ↗
60. The conometric concept for the definitive rehabilitation of a single posterior implant by using a conical indexed abutment: A technique10.1016/j.prosdent.2019.02.020 ↗
61. Ouldyerou, A., Merdji, A., Aminallah, L., Roy, S., Mehboob, H., and Özcan, M. (2022). Biomechanical performance of Ti-PEEK dental implants in bone: An in-silico analysis. J. Mech. Behav. Biomed. Mater., 134.10.1016/j.jmbbm.2022.105422 ↗
62. Effect of Cement Gap on the Retention of Zirconia Crowns10.21608/ajdsm.2020.24992.1009 ↗
63. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK10.1038/s41598-019-50363-1 ↗