Wear of Titanium Implant Platforms with Different Abutment Connections and Abutment Materials: A Pilot Study
Source abstract
Abstract
The most commonly used material in dental implants and their abutments is titanium. Zirconia is a more aesthetic alternative to titanium abutments; however, it is much harder. There are concerns that zirconia could damage the surface of the implant over time, especially in less stable connections. The aim was to evaluate the wear of implants with different platforms connected to titanium and zirconia abutments. A total of six implants were evaluated, two of each connection type: external hexagon, tri-channel, and conical connections (n = 2). Half of the implants were connected to zirconia abutments, and the other half to titanium abutments (n = 3). The implants were then cyclically loaded. The implant platforms were evaluated by digital superimposing micro CT files and calculating the area of the loss surface (wear). In all the implants, a statistically significant loss of the surface area (p = 0.028) was observed when comparing the area before and after cyclic loading. The average lost surface area was 0.38 mm2 with titanium abutments and 0.41 mm2 with zirconia abutments. The average lost surface area was 0.41 mm2 with the external hexagon, 0.38 mm2 with the tri-channel, and 0.40 mm2 with the conical connection. In conclusion, the cyclic loads induced implant wear. However, neither the type of abutment (p = 0.700) nor the connection (p = 0.718) influenced the amount of surface area lost.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisbon, Portugal
Department of Mechanical Engineering, Centre for Mechanical Engineering, Materials and Processes (CEMMPRE), University of Coimbra, 3004-516 Coimbra, Portugal
Laboratório de Instrumentação, Engenharia Biomédica e Física da Radiação (LIBPhys), 1600-277 Lisbon, Portugal
Funding
FCT–Fundação para a Ciência e a Tecnologia
References (43)
Show source-provided references
1. A Brief Historical Perspective on Dental Implants, Their Surface Coatings and Treatments10.2174/1874210601408010050 ↗
2. Biomedical applications of titanium and its alloys10.1007/s11837-008-0031-1 ↗
3. Implant materials, designs, and surface topographies: Their effect on osseointegration. A literature review
4. Aluminum, Alzheimer’s disease and bone fragility10.3109/17453679708999016 ↗
5. Accumulation of aluminum in lamellar bone after implantation of titanium plates, Ti-6Al-4V screws, hydroxyapatite granules10.1016/j.biomaterials.2003.10.020 ↗
6. Ceramic abutments—A new era in achieving optimal esthetics in implant dentistry
7. Improving darkened anterior peri-implant tissue color with zirconia custom implant abutments
8. The effect of all-ceramic and porce-lain-fused-to-metal restorations on marginal peri-implant soft tissue color: A randomized controlled clinical trial
9. The zirconium oxide abutment: An all ceramic abutment for esthetic improvement of implant superstructures
10. Zirconia abutments in the anterior region: A systematic review of mechanical and esthetic outcomes10.1016/j.prosdent.2018.08.005 ↗
11. Anusavice, K.J., Shen, C., and Rawls, H.R. (2013). Philips’ Science of Dental Materials, Elsevier/Saunders. [12th ed.].
12. Wear at the titanium—Titanium and the titanium—Zirconia implant—Abutment interface: A comparative in vitro study10.1016/j.dental.2012.08.008 ↗
13. The ZiReal Post: A New Ceramic Implant Abutment10.1111/j.1708-8240.2003.tb00278.x ↗
14. Pera, F., Menini, M., Alovisi, M., Crupi, A., Ambrogio, G., Asero, S., Marchetti, C., Canepa, C., Merlini, L., and Pesce, P. (2022). Can Abutment with Novel Superlattice CrN/NbN Coatings Influence Peri-Implant Tissue Health and Implant Survival Rate Compared to Machined Abutment? 6-Month Results from a Multi-Center Split-Mouth Randomized Control Trial. Materials, 16.10.3390/ma16010246 ↗
15. Carossa, M., Alovisi, M., Crupi, A., Ambrogio, G., and Pera, F. (2022). Full-Arch Rehabilitation Using Trans-Mucosal Tis-sue-Level Implants with and without Implant-Abutment Units: A Case Report. Dent. J., 10.10.3390/dj10070116 ↗
16. Implants and components: Entering the new millennium
17. Dental implants with internal versus external connections: 5-year post-loading results from a pragmatic multicenter randomised controlled trial
18. Elongation and preload stress in dental implant abutment screws
19. In vitro assessment of connection strength and stability of internal implant-abutment connections10.1016/j.clinbiomech.2019.03.007 ↗
20. Evolution of External and Internal Implant to Abutment Connection10.5005/JP-Journals-10012-1079 ↗
21. Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review10.1007/s10006-015-0494-5 ↗
22. Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review
23. The Core-Vent implant system. The evolution of an osseoventegrated implant
24. Comparison of strength and failure mode of seven implant systems: An in vitro test10.1016/S0022-3913(97)70009-X ↗
25. Three-Dimensional Deformation and Wear of Internal Implant-Abutment Connection: A Comparative Biomechanical Study Using Titanium and Zirconia10.11607/jomi.6349 ↗
26. Wear at the Titanium-Zirconia Implant-Abutment Interface: A Pilot Study
27. Influence of contact configuration and lubricating conditions on the microtriboactivity of the zirconia-Ti6Al4V pair used in dental applications10.1016/j.jmbbm.2018.12.009 ↗
28. (2007). International Standard for Dynamic Fatigue Test for Endosseous Dental Implants. Standard No. ISO 14801.
29. About a synthetic saliva for in vitro studies10.1016/S0039-9140(00)00618-4 ↗
30. Accuracy of full-arch scans using intraoral scanners10.1007/s00784-013-1132-y ↗
31. Imburgia, M., Logozzo, S., Hauschild, U., Veronesi, G., Mangano, C., and Mangano, F.G. (2017). Accuracy of four intraoral scanners in oral implantology: A comparative in vitro study. BMC Oral Health, 17.10.1186/s12903-017-0383-4 ↗
32. Comparision of a non-destructive technique using three-dimensional imaging and histoanatomical chemical dissolution for dental morphology analysis
33. Intra- and Interobserver Variability of Cochlear Length Measurements in Clinical CT10.1097/MAO.0000000000001411 ↗
34. MicroCT morphometry analysis of mouse cancellous bone: Intra- and inter-system reproducibility10.1016/j.bone.2011.05.013 ↗
35. Evaluation of the Fit of CAD/CAM Abutments10.11607/ijp.3501 ↗
36. Misfit of Three Different Implant-Abutment Connections Before and After Cyclic Load Application: An In Vitro Study10.11607/jomi.5629 ↗
37. Comparative analysis of the wear of titanium/titanium and titanium/zirconia interfaces in implant/abutment assemblies after thermocycling and mechanical loading
38. Wear behavior between zirconia and titanium as an antagonist on fixed dental prostheses10.1088/1748-6041/9/2/025005 ↗
39. Wear and Corrosion Interactions at the Tita-nium/Zirconia Interface: Dental Implant Application10.1111/jopr.12769 ↗
40. Mendes, T.A., Caramês, J., Lopes, L.P., and Ramalho, A.L. (2018). Sphere-plane methodology to evaluate the wear of titanium of dental implants: A research proposal. BMC Res. Notes, 11.10.1186/s13104-018-3635-8 ↗
41. The behavior of a zirconia or metal abutment on the implant-abutment interface during cyclic loading10.1016/j.prosdent.2019.09.023 ↗
42. Parameters Determining Micromotion at the Implant-Abutment Interface10.11607/jomi.3762 ↗
43. Influence of abutment and connection type on im-plant-abutment connection rigidity: An in vitro study