journal article·2022-12-13Open access

Surface Heparinization of a Magnesium-Based Alloy: A Comparison Study of Aminopropyltriethoxysilane (APTES) and Polyamidoamine (PAMAM) Dendrimers

Masoumeh Ebrahimi, Atefeh Solouk, Ali Davoodi, Somaye Akbari, Masoumeh Haghbin Nazarpak, Alireza Nouri

Abstract

Magnesium (Mg)-based alloys are biodegradable metallic biomaterials that show promise in minimizing the risks of permanent metallic implants. However, their clinical applications are restricted due to their rapid in vivo degradation and low surface hemocompatibilities. Surface modifications are critically important for controlling the corrosion rates of Mg-based alloys and improving their hemocompatibilities. In the present study, two heparinization methods were developed to simultaneously increase the corrosion resistance and hemocompatibility of the AZ31 Mg alloy. In the first method, the surface of the AZ31 alloy was modified by alkali–heat treatment and then aminolyzed by 3-amino propyltriethoxy silane (APTES), a self-assembly molecule, and heparin was grafted onto the aminolyzed surface. In the second method, before heparinization, polyamidoamine dendrimers (PAMAM4-4) were grafted onto the aminolyzed surface with APTES to increase the number of surface functional groups, and heparinization was subsequently performed. The presence of a peak with a wavelength of about 1560 cm−1 in the FTIR spectrum for the sample modified with APTES and dendrimers indicated aminolysis of the surface. The results indicated that the corrosion resistance of the Mg alloy was significantly improved as a result of the formation of a passive layer following the alkali–heat treatment. The results obtained from a potentiodynamic polarization (PDP) test showed that the corrosion current in the uncoated sample decreased from 25 µA to 3.7 µA in the alkali–heat-treated sample. The corrosion current density was reduced by 14 and 50 times in samples treated with the self-assembly molecules, APTES and dendrimers, respectively. After heparinization, the clotting time for pristine Mg was greatly improved. Clotting time increased from 480 s for the pristine Mg sample to 630 s for the APTES- and heparin-modified samples and to 715 s for the PAMAM- and heparin-modified samples. Cell culture data showed a slight improvement in the cell-supporting behavior of the modified samples.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Aluminum Alloys Composites Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Biomedical Engineering Department, Amirkabir University of Technology (Polytechnic Tehran), Tehran 158754413, Iran

Materials and Metallurgical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad 9177948974, Iran

Sichuan University-Pittsburgh Institute (SCUPI), Chengdu 610207, China

Textile Engineering Department, Amirkabir University of Technology (Polytechnic Tehran), Tehran 158754413, Iran

New Technologies Research Center (NTRC), Amirkabir University of Technology (Polytechnic Tehran), Tehran 158754413, Iran

References (36)

Show source-provided references
1. Cytocompatibility and Hemolysis of AZ31B Magnesium Alloy with Si-containing Coating10.1016/j.jmst.2015.07.008 ↗
2. Enhanced in Vitro and in Vivo Performance of Mg–Zn–Y–Nd Alloy Achieved with APTES Pretreatment for Drug-Eluting Vascular Stent Application10.1021/acsami.6b05038 ↗
3. Arginine-leucine based poly (ester urea urethane) coating for Mg-Zn-Y-Nd alloy in cardiovascular stent applications10.1016/j.colsurfb.2017.07.031 ↗
4. Surface design of biodegradable magnesium alloys—A review10.1016/j.surfcoat.2012.10.009 ↗
5. Controllable biodegradability, drug release behavior and hemocompatibility of PTX-eluting magnesium stents10.1016/j.colsurfb.2010.10.038 ↗
6. Layer-by-layer deposition of bioactive layers on magnesium alloy stent materials to improve corrosion resistance and biocompatibility
7. Wen, C. (2015). 1-Introduction to surface coating and modification for metallic biomaterials. Surface Coating and Modification of Metallic Biomaterials, Woodhead Publishing.
8. Magnesium alloys for biomedical application: Advanced corrosion control through surface coating10.1016/j.surfcoat.2020.126521 ↗
9. A silk-based coating containing GREDVY peptide and heparin on Mg–Zn–Y–Nd alloy: Improved corrosion resistance, hemocompatibility and endothelialization10.1039/C7TB02784B ↗
10. Hemocompatibility and selective cell fate of polydopamine-assisted heparinized PEO/PLLA composite coating on biodegradable AZ31 alloy10.1016/j.colsurfb.2014.06.036 ↗
11. Zhao, N., and Zhu, D. (2014). Collagen Self-Assembly on Orthopedic Magnesium Biomaterials Surface and Subsequent Bone Cell Attachment. PLoS ONE, 9.10.1371/journal.pone.0110420 ↗
12. Effects of self-assembly of 3-phosphonopropionic acid, 3-aminopropyltrimethoxysilane and dopamine on the corrosion behaviors and biocompatibility of a magnesium alloy10.1016/j.msec.2016.05.038 ↗
13. Hybrid epoxy–silane coatings for improved corrosion protection of Mg alloy10.1016/j.corsci.2012.10.013 ↗
14. Corrosion resistance and biocompatibility of magnesium alloy modified by alkali heating treatment followed by the immobilization of poly (ethylene glycol), fibronectin and heparin10.1016/j.msec.2016.09.028 ↗
15. The influence of silane and silane–PMMA coatings on the in vitro biodegradation behavior of AE42 magnesium alloy for cardiovascular stent applications10.1039/C6RA23384H ↗
16. A review on synthesis, photophysical properties, and applications of dendrimers with perylene core10.1016/j.eurpolymj.2020.109933 ↗
17. Biological applications of dendrimers10.1016/S1367-5931(02)00400-3 ↗
18. PAMAM Dendrimer Nanomolecules Utilized as Drug Delivery Systems for Potential Treatment of Glioblastoma: A Systematic Review10.2147/IJN.S243155 ↗
19. Amine-terminated dendritic polymers as promising nanoplatform for diagnostic and therapeutic agents’ modification: A review10.1016/j.ejmech.2021.113572 ↗
20. The synergistic effect of polyamidoamine dendrimers and sodium silicate on the corrosion of carbon steel in soft water10.1016/j.corsci.2014.10.054 ↗
21. Fabrication of chitosan/heparinized graphene oxide multilayer coating to improve corrosion resistance and biocompatibility of magnesium alloys10.1016/j.msec.2019.109947 ↗
22. Layered double hydroxide/poly-dopamine composite coating with surface heparinization on Mg alloys: Improved anticorrosion, endothelialization and hemocompatibility10.1039/C8BM00298C ↗
23. Heparin/poly-l-lysine nanoplatform with growth factor delivery for surface modification of cardiovascular stents: The influence of vascular endothelial growth factor loading10.1002/jbm.a.36902 ↗
24. Enhanced Anti-corrosion Ability and Biocompatibility of PLGA Coatings on MgZnYNd Alloy by BTSE-APTES Pre-treatment for Cardiovascular Stent10.1016/j.jmst.2016.06.021 ↗
25. Biomimetic modified clinical-grade POSS-PCU nanocomposite polymer for bypass graft applications: A preliminary assessment of endothelial cell adhesion and haemocompatibility10.1016/j.msec.2014.10.065 ↗
26. Electrospun polyethylene terephthalate (PET) nanofibrous conduit for biomedical application10.1002/pat.4768 ↗
27. Pavia, D.L., Lampman, G.M., Kriz, G.S., and Vyvyan, J.A. (1996). Introduction to Spectroscopy: A Guide for Students of Organic Chemistry, Cengage Learning.
28. Chauhan, A.S. (2018). Dendrimers for Drug Delivery. Molecules, 23.10.3390/molecules23040938 ↗
29. Biofunctionalized anti-corrosive silane coatings for magnesium alloys10.1016/j.actbio.2012.12.025 ↗
30. Functionalisation of porous silica powders in a fluidised-bed reactor with glycidoxypropyltrimethoxysilane (GPTMS) and aminopropyltriethoxysilane (APTES)10.1016/j.cherd.2009.11.005 ↗
31. Evaluation of Haemocompatibility of TLM Titanium Alloy with Surface Heparinization10.1016/S1875-5372(10)60023-9 ↗
32. Dendrimers: A new class of corrosion inhibitors for mild steel in 1M HCl: Experimental and quantum chemical studies10.1016/j.molliq.2016.10.117 ↗
33. Electrochemical impedance spectroscopic investigation of the role of alkaline pre-treatment in corrosion resistance of a silane coating on magnesium alloy, ZE4110.1016/j.electacta.2011.02.050 ↗
34. Dendritic Chelating Agents. 1. Cu(II) Binding to Ethylene Diamine Core Poly (amidoamine) Dendrimers in Aqueous Solutions10.1021/la036108k ↗
35. Incorporation of heparin/BMP2 complex on GOCS-modified magnesium alloy to synergistically improve corrosion resistance, anticoagulation, and osteogenesis10.1007/s10856-021-06497-8 ↗
36. Engineered hemostatic bionanocomposite of Poly (lactic acid) electrospun mat amino-modified halloysite for potential application in wound healing10.1002/pat.5399 ↗