journal article·2025-04-03Open access

The Evaluation of Restored Proximal Contact Areas with Four Direct Adherent Biomaterials: An In Vitro Study

Elena-Cristina Marcov, Mihai Burlibașa, Narcis Marcov, Florentina Căminișteanu, Andreea Angela Ștețiu, Mircea Popescu, Radu-Cătălin Costea, Raluca Mariana Costea, Liliana Burlibașa, Andi Ciprian Drăguș, Maria Antonia Ștețiu, Dana Cristina Bodnar

Abstract

The aim of this study was to compare the interproximal contact tightness of lateral teeth after restoring adjacent proximal walls with four types of direct adherent biomaterials. Distal and mesial boxes were prepared on 160 artificial right first and second upper molars. Each set of 40 pairs of boxes was restored using one bulk biomaterial: Equia Forte Fil HT (GC), Cention® Forte (IVOCLAR VIVADENT), Admira Fusion x-tra (VOCO), or 3MTMFiltekTM One Bulk Fill. The mean difference in the passing-through force varied from sound to restored surfaces immediately after application, as well as at 7 and 14 days after: Equia Forte Fil HT—4.07 ± 0.01, 4.08 ± 0.01, and 4.11 ± 0.01; Cention® Forte—3.30 ± 0.01, 3.50 ± 0.01, and 3.56 ± 0.01; Admira Fusion x-tra—4.10 ± 0.01, 4.13 ± 0.01, and 4.13 ± 0.01; 3MTMFiltekTM One Bulk Fill—4.08 ± 0.01, 4.09 ± 0.01, and 4.07 ± 0.01 (p < 0.05). The passing-through force of the restored contact areas showed significantly higher values when compared to those for the sound surfaces, and among them, all biomaterials presented similar values, except for Cention® Forte. The potential clinical relevance of this study relates to better knowing the most appropriate restorative material for large proximal caries on adjacent surfaces from the outset of the treatment protocol.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Orthodontics and Dentofacial Orthopedics · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Operative Dentistry, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 010221 Bucharest, Romania

Department of Dental Technology, Faculty of Midwifery and Nursing, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania

Faculty of Medicine, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania

Doctoral School, “Carol Davila” University of Medicine and Pharmacy, 37 Dionisie Lupu Street, 020021 Bucharest, Romania

S.C Dentexpert Magic, 050514 Bucharest, Romania

Genetics Department, Faculty of Biology, University of Bucharest, 060101 Bucharest, Romania

Funding

University of Medicine and Pharmacy Carol Davila, through the institutional program Publish not Perish.

References (37)

Show source-provided references
1. Romînu, M., Bratu, D., Uram-Ţuculescu, S., Muntean, M., Fabricky, M., Colojoară, C., Negruţiu, M., and Bratu, E. (1997). Date de Morfologie Funcţională Clinică. Aparatul Dento-Maxilar, Ed. Helicon.
2. Ritter, A.V., Boushell, L.W., and Walter, R. (2019). Sturdevant’s Art and Science of Operative Dentistry, Elsevier/Mosby. [7th ed.].
3. Factors influencing proximal dental contact strength10.1034/j.1600-0722.2000.108005368.x ↗
4. Marcov, E.C., Marcov, N., and Bodnar, D.C. (2020). Protocoale de Tratament al Leziunilor Coronare, Ed. Universitară “Carol Davila”.
5. Filler characteristics of modern dental resin composites and their influence on physico-mechanical properties10.1016/j.dental.2016.09.034 ↗
6. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites10.1007/s00784-013-1177-y ↗
7. Curing characteristics of flowable and sculptable bulk-fill composites10.1007/s00784-016-1894-0 ↗
8. Effective Protocol for Daily High-quality Direct Posterior Composite Restorations. The Interdental Anatomy of the Class-2 Composite Restoration
9. Abbassy, K.M., Elmahy, W.A., and Holiel, A.A. (2023). Evaluation of the proximal contact tightness in class II resin composite restorations using different contact forming instruments: A 1-year randomized controlled clinical trial. BMC Oral Health, 23.10.1186/s12903-023-03462-5 ↗
10. In vitro Comparison of the Efficiency of Celluloid and metallic matrices in Proximal Restorations with a Bulk Polymer-based Biomaterial10.37358/MP.24.2.5715 ↗
11. Evaluation and development of digital device for measuring proximal tooth contact tightness
12. Comparison of proximal contacts of Class II resin composite restorations in vitro10.2341/05-133 ↗
13. (2023, February 12). Available online: https://www.gc.dental/europe/en/products/equiaforteht.
14. (2023, February 15). Available online: https://www.ivoclar.com/ro_ro/products/composites/cention-forte.
15. (2023, February 15). Available online: https://www.voco.dental/us/products/direct-restoration/nano-ormocer/admira-fusion-x-tra.
16. (2023, February 17). Available online: https://www.3m.com/3M/en_LB/p/d/b00008028/.
17. Peskersoy, C., Sener, M., Gurses, O.B., Erbil, E., and Turkun, M. (2024). Evaluation of Proximal Contact Tightness and Contact Area of Posterior Composite Resin Restorations. Appl. Sci., 14.10.3390/app14188335 ↗
18. Evaluation of Matrix Systems on the Proximal Contact of Class II Composite Restorations: A Systematic Review
19. Proximal contact tightness of direct Class II composite resin restorations with various matrix systems: A systematic review10.4103/JCDE.JCDE_203_23 ↗
20. Evaluation of proximal contact tightness of Class II resin composite restorations10.2341/09-037L ↗
21. Effect of Matrix Systems and Filling Materials on ProximalContacts in Primary Molar Restorations: An In Vitro Study10.9734/ajds/2025/v8i1220 ↗
22. Influence of volumetric shrinkage and curing light intensity on proximal contact tightness of class II resin composite restorations: In vitro study10.2341/11-269-L ↗
23. Polymerization shrinkage kinetics and shrinkage-stress in dental resin-composites10.1016/j.dental.2016.05.006 ↗
24. Effects of Adjacent Tooth Type and Occlusal Fatigue on Proximal Contact Force of Posterior Bulk Fill and Incremental Resin Composite Restoration10.2341/20-019-L ↗
25. Paolone, G., Mazzitelli, C., Josic, U., Scotti, N., Gherlone, E., Cantatore, G., and Breschi, L. (2022). Modeling Liquids and Resin-Based Dental Composite Materials—A Scoping Review. Materials, 15.10.3390/ma15113759 ↗
26. Proximal contact tightness of class Ⅱ bulk-fill composite resin restorations: An in vitro study10.4012/dmj.2017-279 ↗
27. Randomized prospective clinical trial of class II restorations using flowable bulk-fill resin composites: 4-year follow-up10.1007/s00784-022-04526-6 ↗
28. Three-year Randomized Prospective Clinical Trial of Class II Restorations Using Flowable Bulk-fill Resin Composites10.2341/20-031-C ↗
29. Randomized Prospective Clinical Trial of Class II Restorations Using Low-shrinkage Flowable Resin Composite10.2341/18-230-C ↗
30. Intensidad del Punto de Contacto en Resinas Clase II. Revisión Sistemática10.4067/S0718-381X2021000400882 ↗
31. Proximal contact tightness for Class II direct composite resin restorations: A literature review10.12968/denu.2021.48.9.733 ↗
32. Proximal contact tightness between two different restorative materials—An in vitro study
33. Quality of approximal surfaces of posterior restorations in primary molars10.2334/josnusd.21-0264 ↗
34. Knowledge, Practice and Believes Regarding Class II Restoration Proximal Contact among Dental Practitioners
35. Scope of an alkasite restorative material in paediatric dentistry: A review10.18231/j.ijohd.2023.017 ↗
36. Derchi, G., Marchio, V., Giuca, M.R., and Lardani, L. (2022). Clinical Performance of CentionTM Alkasite Restorative Material vs. Glass Ionomer Cement Used in Deciduous Teeth: One-Year Evaluation. Appl. Sci., 12.10.3390/app122110845 ↗
37. Clinical effectiveness of alkasite versus nanofilled resin composite in the restoration of occlusal carious lesions in permanent molar teeth of children: A randomized clinical trial10.1007/s40368-023-00788-0 ↗