journal article·2024-09-09Open access

Effects of Loading Forces, Loading Positions, and Splinting of Two, Three, or Four Ti-Zr (Roxolid®) Mini-Implants Supporting the Mandibular Overdentures on Peri-Implant and Posterior Edentulous Area Strains

Nikola Petricevic, Asja Celebic, Dario Puljic, Ognjen Milat, Alan Divjak, Ines Kovacic

Abstract

Clinical indications for the Ti-Zr alloy (Roxolid®) mini-implants (MDIs) in subjects with narrow ridges are still under review. The aim was to analyze peri-implant and posterior edentulous area strains dependent on the MDI number, splinting status, loading force, and loading position. Six models were digitally designed and printed. Two, three, or four Ti-Zr MDIs, splinted with a bar or unsplinted (single units), supported mandibular overdentures (ODs), loaded with 50–300 N forces unilaterally, bilaterally, and anteriorly. The artificial mucosa thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sides of each MDI, and on the posterior edentulous area under the ODs. Loadings were performed through the metal plate placed on ODs’ artificial teeth (15 times repeated). Arithmetic means with standard deviations and the significance of the differences (MANOVA, Sheffe post hoc) were calculated. Different MDI numbers, loading positions, forces, and splinting elicited different peri-implant microstrains. In the two-MDI models, 300 N force during unilateral loading elicited the highest microstrains (almost 3000 εμ on the loaded side), which can jeopardize bone reparation. On the opposite side, >2500 εμ was registered, which represents high strains. During bilateral loadings, microstrains hardly exceeded 2000 εμ, indicating that bilateral chewers or subjects having lower forces can benefit from the two Ti-Zr MDIs, irrespective of splinting. However, in subjects chewing unilaterally, and inducing higher forces (natural teeth antagonists), or bruxers, only two MDIs may not be sufficient to support the OD. By increasing implant numbers, peri-implant strains decrease in both splinted and single-unit MDI models, far beyond values that can interfere with bone reparation, indicating that splinting is not necessary. When the positions of the loading forces are closer to the implant, higher peri-implant strains are induced. Regarding the distal edentulous area, microstrains reached 2000 εμ only during unilateral loadings in the two-MDI models, and all other strains were lower, below 1500 εμ, confirming that implant-supported overdentures do not lead to edentulous ridge atrophy.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia

Institute of Physics, 10000 Zagreb, Croatia

Department of Digital Arts, University Algebra, 10000 Zagreb, Croatia

Funding

Ti-Zr (Roxolid®) mini-implants from the Institute Straumann AG

References (63)

Show source-provided references
1. The clinical and radiographic outcome of immediately loaded mini implants supporting a mandibular overdenture. A 3-year prospective study10.1111/j.1365-2842.2011.02213.x ↗
2. Mini-implants and narrow diameter implants as mandibular overdenture retainers: A systematic review and meta-analysis of clinical and radiographic outcomes10.1111/joor.12585 ↗
3. A prospective cohort study on survival and success of one-piece mini-implants with associated changes in oral function: Five-year outcomes10.1111/clr.13444 ↗
4. Clinical outcomes and bone-level alterations around one-piece mini dental implants retaining mandibular overdentures: 5-year follow-up of a prospective cohort study10.1111/clr.13591 ↗
5. Clinical outcome of removable prostheses supported by mini dental implants. A systematic review10.1080/00016357.2018.1499958 ↗
6. Treatment Outcomes for Mandibular Mini-Implant-Retained Overdentures: A Systematic Review10.11607/ijp.4929 ↗
7. Histomorphometric Analysis of Flaplessly Placed and Early Loaded One-Piece Mini Dental Implants in Overdenture Patients10.11607/prd.6309 ↗
8. Mandibular overdenture retained by four one-piece titanium-zirconium mini implants: A 2-year RCT on patient-reported outcomes10.1016/j.jdent.2024.105267 ↗
9. Celebic, A., Kovacic, I., Petricevic, N., Alhajj, M.N., Topic, J., Junakovic, L., and Persic-Kirsic, S. (2024). Clinical Outcomes of Three vs. Four Mini-Implants Retaining Mandibular Overdenture: A 5-Year Randomized Clinical Trial. Medicina, 60.10.3390/medicina60010017 ↗
10. Oral Health-Related Quality of Life in Different Types of Mandibular Implant Overdentures in Function Longer Than 3 Years10.11607/ijp.4457 ↗
11. Comparative clinical study of conventional dental implant and mini dental implant-retained mandibular overdenture: A 5- to 8-Year prospective clinical outcomes in a previous randomized clinical trial10.1111/cid.13098 ↗
12. Are implant-supported removable partial dentures a suitable treatment for partially edentulous patients? A systematic review and meta-analysis10.1016/j.prosdent.2021.06.017 ↗
13. Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food
14. Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes10.1111/clr.13342 ↗
15. Mini-implant mandibular overdentures under a two-step immediate loading protocol: A 4-6-year retrospective study10.1111/ger.12683 ↗
16. Narrow-diameter implants: A systematic review and meta-analysis10.1111/clr.13272 ↗
17. A cohort study on short mini-implants for mandibular overdentures compared to those of standard length10.1111/clr.13542 ↗
18. Factors and clinical outcomes for standard and mini-implants retaining mandibular overdentures: A systematic review and meta-analysis10.1016/j.prosdent.2021.11.010 ↗
19. Rosa, A., Pujia, A.M., De Angelis, R., and Arcuri, C. (2023). Narrow Implants and Overdentures in the Total Rehabilitation of Atrophic Edentulous Jaws: Review of Clinical Aspects with Meta-Analysis. Prosthesis, 6.10.3390/prosthesis6010003 ↗
20. Mini vs. Standard Implants for Mandibular Overdentures: A Randomized Trial10.1177/0022034515601959 ↗
21. Evaluation of a New Titanium-Zirconium Dental Implant: A Biomechanical and Histological Comparative Study in the Mini Pig: Bone integration of TiZr1317 implants10.1111/j.1708-8208.2010.00289.x ↗
22. Mechanical property assessment of bone healing around a titanium-zirconium alloy dental implant10.1111/cid.12061 ↗
23. The osseointegration behaviour of titanium-zirconium implants in ovariectomized rabbits10.1111/clr.12141 ↗
24. A review in titanium-zirconium binary alloy for use in dental implants: Is there an ideal Ti-Zr composing ratio?10.1016/j.jdsr.2023.01.002 ↗
25. Clinical outcomes of titanium-zirconium alloy narrow-diameter implants for single-crown restorations: A systematic review and meta-analysis10.1016/j.bjoms.2023.05.005 ↗
26. Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study10.1111/jcpe.12468 ↗
27. Use of a New-Generation Mini-Implant and Attachment System for Fabrication of a Maxillary Overdenture10.11607/ijp.6544 ↗
28. Implant survival/success and peri-implant outcomes of titanium-zirconium mini implants for mandibular overdentures: Results from a 1-year randomized clinical trial10.1111/clr.14102 ↗
29. Flapped versus flapless surgery and delayed versus immediate loading for a four mini implant mandibular overdenture: A RCT on post-surgical symptoms and short-term clinical outcomes10.1111/clr.13974 ↗
30. Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium-zirconium mini-implants for overdentures: A cross sectional analysis10.1111/cid.13181 ↗
31. Puljic, D., Celebic, A., Kovacic, I., and Petricevic, N. (2024). Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study. Appl. Sci., 14.10.3390/app14052150 ↗
32. Puljic, D., Petricevic, N., Celebic, A., Kovacic, I., Milos, M., Pavic, D., and Milat, O. (2024). Mandibular Overdenture Supported by Two or Four Unsplinted or Two Splinted Ti-Zr Mini-Implants: In Vitro Study of Peri-Implant and Edentulous Area Strains. Biomimetics, 9.10.3390/biomimetics9030178 ↗
33. A 2003 update of bone physiology and Wolff’s Law for clinicians
34. The influence of static and dynamic loadingon marginal bone reactions around osseointegrated implants: An animal experimental study10.1034/j.1600-0501.2001.012003207.x ↗
35. Fracture of a narrow-diameter roxolid implant: Clinical and fractographic considerations10.11607/jomi.3573 ↗
36. Influence of forces on peri-implant bone10.1111/j.1600-0501.2006.01360.x ↗
37. Mandibular Implant-supported Overdentures and Oral Function10.1111/j.1600-0501.2010.01915.x ↗
38. Can Bite-Force Measurement Play a Role in Dental Treatment Planning, Clinical Trials, and Survival Outcomes? A Literature Review and Clinical Recommendations
39. Bite Force Evaluation in Complete Denture Wearer with Different Denture Base Materials: A Randomized Controlled Clinical Trial10.4103/jispcd.JISPCD_2_18 ↗
40. Sobh, M.M., Abdalbary, M., Elnagar, S., Nagy, E., Elshabrawy, N., Abdelsalam, M., Asadipooya, K., and El-Husseini, A. (2022). Secondary Osteoporosis and Metabolic Bone Diseases. J. Clin. Med., 11.10.3390/jcm11092382 ↗
41. Kupka, J.R., Sagheb, K., Al-Nawas, B., and Schiegnitz, E. (2023). The Sympathetic Nervous System in Dental Implantology. J. Clin. Med., 12.10.3390/jcm12082907 ↗
42. Cannarella, R., Barbagallo, F., Condorelli, R.A., Aversa, A., La Vignera, S., and Calogero, A.E. (2019). Osteoporosis from an Endocrine Perspective: The Role of Hormonal Changes in the Elderly. J. Clin. Med., 8.10.3390/jcm8101564 ↗
43. Decaux, G. (2023). Morbidity Associated with Chronic Hyponatremia. J. Clin. Med., 12.10.3390/jcm12030978 ↗
44. Wach, T., Szymor, P., Trybek, G., Sikora, M., Michcik, A., and Kozakiewicz, M. (2024). Bone Metabolism and Dental Implant Insertion as a Correlation Affecting on Marginal Bone Remodeling: Texture Analysis and the New Corticalization Index, Predictor of Marginal Bone Loss-3 Months of Follow-Up. J. Clin. Med., 13.10.3390/jcm13113212 ↗
45. Biting and chewing in overdentures, full dentures, and natural dentitions10.1177/00220345000790071501 ↗
46. Subjective and Objective Assessment of Chewing Performance in Older Adults with Different Dental Occlusion10.1159/000529240 ↗
47. Improving masticatory performance, bite force, nutritional state and patient’s satisfaction with implant overdentures: A systematic review of the literature10.1111/joor.12241 ↗
48. The impact of occluding pairs on the chewing patterns among the elderly10.1016/j.jdent.2020.103511 ↗
49. Peri-implant biomechanical responses to standard, short-wide, and mini implants supporting singlecrowns under axial and off-axial loading (an in vitro study)10.1563/AAID-JOI-D-11-00102 ↗
50. Reliability of Grayscale Value for Bone Density Determination in Oral Rehabilitation using Dental Implants10.4103/ijabmr.ijabmr_3_23 ↗
51. Influence of Adhesive on Optical Fiber-Based Strain Measurements on Printed Circuit Boards10.1007/s10854-023-10017-5 ↗
52. Occlusal force distribution on the dental arch during various levels of clenching10.1046/j.1365-2842.1999.00473.x ↗
53. Is bruxism associated with changes in neural pathways? A systematic review and meta-analysis of clinical studies using neurophysiological techniques10.1007/s11682-021-00601-w ↗
54. The effect of maximum bite force on marginal bone loss of mini-implants supporting a mandibular overdenture: A randomized controlled trial10.1111/j.1600-0501.2009.01834.x ↗
55. Celebic, A., Kovacic, I., Petricevic, N., Puljic, D., Popovac, A., and Kirsic, S.P. (2023). Mini-Implants Retaining Removable Partial Dentures in Subjects without Posterior Teeth: A 5-Year Prospective Study Comparing the Maxilla and the Mandible. Medicina, 59.10.3390/medicina59020237 ↗
56. Orofacial esthetics, chewing function, and oral health-related quality of life in Kennedy class I patients with mini-implant-retained removable partial dentures: A 3-year clinical prospective study10.1007/s00784-024-05741-z ↗
57. Survival and Stability of Strategic Mini-Implants with Immediate or Delayed Loading under Removable Partial Dentures: A 3-Year Randomized Controlled Clinical Trial10.1007/s00784-022-04805-2 ↗
58. Residual ridge atrophy in complete denture wearers and relationship with densitometric values of a cervical spine: A hierarchical regression analysis10.1111/j.1741-2358.2011.00589.x ↗
59. Bone resorption in different parts of the mandible in patients restored with an implant overdenture. A retrospective radiographic analysis10.1111/clr.12523 ↗
60. Decreasing of residual alveolar ridge height in complete denture wearers. A five year follow up study
61. The continuing reduction of the residual alveolar ridges in complete denture wearers: A mixed-longitudinal study covering 25 years10.1016/S0022-3913(03)00158-6 ↗
62. Implant-supported mandibular overdentures can minimize mandibular bone resorption in edentulous patients: Results of a long-term radiologic evaluation10.11607/jomi.4009 ↗
63. Effects of conventional complete dentures and implant-supported overdentures on alveolar ridge height and mandibular bone structure: 2-year and 6-year follow-up study10.1007/s00784-022-04519-5 ↗