journal article·2024-05-15Open access

The Impact of Open versus Closed Computer-Aided Design/Computer-Aided Manufacturing Systems on the Marginal Gap of Zirconia-Reinforced Lithium Silicate Single Crowns Evaluated by Scanning Electron Microscopy: A Comparative In Vitro Study

Asaf Shely, Joseph Nissan, Ofir Rosner, Eran Zenziper, Diva Lugassy, Khadija Abidulkrem, Gil Ben-Izhack

Abstract

This study aimed to compare the impact of CAD/CAM closed systems and open systems on the marginal gap of monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns, as both systems are used in everyday dentistry, both chair-side and laboratory. For the closed system, 20 plastic teeth were scanned by a Primescan intra-oral scanner (IOS), and for the open system, the same number of plastic teeth were scanned by Trios 4 IOS. For the closed system, CEREC software was used, and for the open system, EXOCAD software was used. All 40 ZLS crowns were grinded by the same four-axis machine and cemented with Temp-bond, followed by self-adhesive resin cement. For each type of cement, an evaluation of the marginal gap was conducted by scanning electron microscopy (SEM). Before comparisons between the groups, a Kolmogorov–Smirnov test was performed on the study variables showing a normal distribution (p > 0.05). Independent T tests (α = 0.05) and paired-sample T tests (α = 0.05) were used. The independent T test found no significant mean marginal gap differences in the zirconia-reinforced lithium silicate crowns bonded with Temp-bond and scanned by Primescan (28.09 μm ± 3.06) compared to Trios 4 (28.94 μm ± 3.30) (p = 0.401), and there was no significant mean marginal gap differences in zirconia-reinforced lithium silicate crowns bonded with self-adhesive resin cement (Gcem ONE) and scanned by Primescan (46.70 μm ± 3.80) compared to Trios 4 (47.79 μm ± 2.59) (p = 0.295). Paired-sample T tests showed significantly higher mean marginal gaps with Gcem ONE compared to Temp-bond for the total mean marginal gap when scanning with Primescan (p = 0.0005) or Trios 4 (p = 0.0005). In everyday dentistry, both closed systems (Primescan with Cerec) and open systems (Trios 4 with Exocad) can be used to achieve an acceptable (<120 µm) marginal gap for ZLS CELTRA® DUO single crowns. There is a significant difference between cementation with Temp-bond and Gcem ONE self-adhesive resin cement (p < 0.05).
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

Department of Orthodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

References (38)

Show source-provided references
1. Intraoral Digital Impression Technique: A Review10.1111/jopr.12218 ↗
2. A comparison of the marginal fit of crowns fabricated with digital and conventional methods10.1016/j.prosdent.2013.12.002 ↗
3. Comparison of the Fit of Lithium Disilicate Crowns made from Conventional, Digital, or Conventional/Digital Techniques
4. Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial10.1111/jopr.12410 ↗
5. Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study10.1007/s00784-016-1924-y ↗
6. Ferrini, F., Sannino, G., Chiola, C., Capparé, P., Gastaldi, G., and Gherlone, E.F. (2019). Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns. Int. J. Environ. Res. Public Health., 16.10.3390/ijerph16040544 ↗
7. Comparing the accuracy of six intraoral scanners on prepared teeth and effect of scanning sequence10.4047/jap.2020.12.5.299 ↗
8. Nulty, A.B. (2021). A Comparison of Full Arch Trueness and Precision of Nine Intra-Oral Digital Scanners and Four Lab Digital Scanners. Dent. J., 9.10.20944/preprints202105.0165.v1 ↗
9. Jivănescu, A., Bara, A., Faur, A.-B., and Rotar, R.N. (2021). Is There a Significant Difference in Accuracy of Four Intraoral Scanners for Short-Span Fixed Dental Prosthesis? A Comparative In Vitro Study. Appl. Sci., 11.10.3390/app11188280 ↗
10. Marginal fit of zirconia copings fabricated after conventional impression making and digital scanning: An in vitro study10.1016/j.prosdent.2020.02.011 ↗
11. How the confocal laser scanning microscope entered biological research10.1016/S0248-4900(03)00078-9 ↗
12. Recent advances in dental optics–Part I: 3D intraoral scanners for restorative dentistry10.1016/j.optlaseng.2013.07.017 ↗
13. Signal-to-noise ratio in confocal microscope systems10.1111/j.1365-2818.1992.tb03264.x ↗
14. Considerations in measurement of marginal fit10.1016/0022-3913(89)90170-4 ↗
15. The estimation of cement film thickness by an in vivo technique10.1038/sj.bdj.4802708 ↗
16. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: A systematic review and meta-analysis10.1016/j.prosdent.2016.01.028 ↗
17. Sadeqi, H.A., Baig, M.R., and Al-Shammari, M. (2021). Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems. Materials, 14.10.3390/ma14216346 ↗
18. Comparison of the Marginal Fit of Procera AllCeram Crowns with Two Finish Lines
19. Fit of a New Pressure-Sintered Zirconium Dioxide Coping
20. MicroComputed Tomography Evaluation of Marginal Fit of Lithium Disilicate Crowns Fabricated by Using Chairside CAD/CAM Systems or the Heat-Pressing Technique10.1016/j.prosdent.2014.04.028 ↗
21. The marginal fit of CAD/CAM monolithic ceramic and metal-ceramic crowns10.1111/jopr.12590 ↗
22. A systematic review of CAD/CAM fit restoration evaluations10.1111/joor.12205 ↗
23. A new in vitro model to study the relationship of gap size and secondary caries10.1159/000107934 ↗
24. Relationship between crowns and the periodontium: A literature update
25. Wear, strength, modulus and hardness of CAD/CAM restorative materials10.1016/j.dental.2016.08.222 ↗
26. The zirconia-reinforced lithium silicate ceramic: Lights and shadows of a new material10.4012/dmj.2016-041 ↗
27. Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: A literature review10.1016/j.jdent.2021.103661 ↗
28. Ben-Izhack, G., Shely, A., Naishlos, S., Glikman, A., Frishman, L., Meirowitz, A., and Dolev, E. (2021). The Influence of Three Different Digital Cement Spacers on the Marginal Gap Adaptation of Zirconia-Reinforced Lithium Silicate Crowns Fabricated by CAD-CAM System. Appl. Sci., 11.10.3390/app112210709 ↗
29. Seeing is believing? When scanning electron microscopy (SEM) meets clinical dentistry: The replica technique10.1002/jemt.23503 ↗
30. Panorama of dental CAD/CAM restorative systems
31. Advancements in CAD/CAM technology: Options for practical implementation
32. Analysis of vertical marginal discrepancy in feldspathic porcelain crowns manufactured with different CAD/CAM systems: Closed and open10.4103/ejd.ejd_368_17 ↗
33. Ben-Izhack, G., Shely, A., Koton, O., Meirowitz, A., Levartovsky, S., and Dolev, E. (2021). (In-Vitro Comparison between Closed Versus Open CAD/CAM Systems) Comparison between Closed and Open CAD/CAM Systems by Evaluating the Marginal Fit of Zirconia-Reinforced Lithium Silicate Ceramic Crowns. Appl. Sci., 11.10.3390/app11104534 ↗
34. Does cad software affect the marginal and internal fit of milled full ceramic crowns?10.1590/1807-3107bor-2022.vol36.0042 ↗
35. Marginal Fit and Retention Strength of Zirconia Crowns Cemented by Self-adhesive Resin Cements10.2341/16-367-L ↗
36. Dapieve, K.S., Pilecco, R.O., Temp, R.W., Villetti, M.A., Pereira, G.K.R., and Valandro, L.F. (2023). Adhesion to lithium disilicate glass-ceramics after aging: Resin viscosity and ceramic surface treatment effects. J. Mech. Behav. Biomed. Mater., 142.10.1016/j.jmbbm.2023.105819 ↗
37. Evaluation of the marginal and internal gaps of partially crystallized versus fully crystallized zirconia-reinforced lithium silicate CAD-CAM crowns: An in vitro comparison of the silicone replica technique, direct view, and 3-dimensional superimposition analysis10.1016/j.prosdent.2021.07.024 ↗
38. Di Fiore, A., Zuccon, A., Carraro, F., Basilicata, M., Bollero, P., Bruno, G., and Stellini, E. (2023). Assessment Methods for Marginal and Internal Fit of Partial Crown Restorations: A Systematic Review. J. Clin. Med., 12.10.3390/jcm12155048 ↗