Enhancing Tissue Equivalence in 7Li Heavy Ion Therapy with MC Algorithm Optimized Polymer-Based Bioinks
Source abstract
Abstract
The unique physical properties of heavy ion beams, particularly their distinctive depth–dose distribution and sharp lateral dose reduction profiles, have led to their widespread adoption in tumor therapy worldwide. However, the physical properties of heavy ion beams must be investigated to deliver a sufficient dose to tumors without damaging organs at risk. These studies should be performed on phantoms made of biomaterials that closely mimic human tissue. Polymers can serve as soft tissue substitutes and are suitable materials for building radiological phantoms due to their physical, mechanical, biological, and chemical properties. Extensive research, development, and applications of polymeric biomaterials have been encouraged due to these properties. In this study, we investigated the ionization, recoils, phonon release, collision events, and lateral straggle properties of polymeric biomaterials that closely resemble soft tissue using lithium-ion beams and Monte Carlo Transport of Ions in Matter simulation. The results indicated that the Bragg peak position closest to soft tissue was achieved with a 7.3% difference in polymethylmethacrylate, with an average recoils value of 10.5%. Additionally, average values of 33% were observed in collision events and 22.6% in lateral straggle. A significant contribution of this study to the existing literature lies in the exploration of secondary interactions alongside the assessment of linear energy transfer induced by the 7Li beam used for treatment. Furthermore, we analyzed the tissue-equivalent properties of polymer biomaterials using heavy ion beams, taking into account phonon release resulting from ionization, recoils, lateral straggle, and all other interactions. This approach allows for the evaluation of the most suitable polymeric biomaterials for heavy ion therapy while considering the full range of interactions involved.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Radiation Therapy and Dosimetry · Advanced Radiotherapy Techniques · Radiation Effects in Electronics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Nuclear Sciences, Ankara University, 06100 Ankara, Turkey
Artificial Intelligence and Data Engineering, Ankara University, 06100 Ankara, Turkey
Faculty of Medicine and Health Technology, Tampere University, 33014 Tampere, Finland
References (46)
Show source-provided references
1. Simulation based analysis of 4He, 7Li, 8Be and 10B ions for heavy ion therapy
2. Secondary radiation measurements for particle therapy applications: Prompt photons produced by 4He.12C and 16O ion beams in a PMMA target
3. Carbon-ion radiotherapy for inoperable head and neck bone and soft-tissue sarcoma: Prospective observational study10.21873/anticanres.15614 ↗
4. Characterizing the Potency and Impact of Carbon Ion Therapy in a Primary Mouse Model of Soft Tissue Sarcoma Relative Potency of Carbon Ions in Primary Mouse Sarcomas10.1158/1535-7163.MCT-17-0965 ↗
5. Horst, F., Schardt, D., Iwase, H., Schuy, C., Durante, M., and Weber, U. (2021). Physical characterization of 3He ion beams for radiotherapy and comparison with 4He. Phys. Med. Biol., 66.10.1088/1361-6560/abef88 ↗
6. Dose and dose averaged LET comparison of 1H, 4He, 6Li, 8Be, 10B, 12C, 14N and 16O ion beams forming a spread-out Bragg peak10.1118/1.3662911 ↗
7. Comparative study of depth-dose distributions for beams of light and heavy nuclei in tissue-like media10.1016/j.nimb.2008.02.025 ↗
8. Investigation of tissue equivalence of phantom biomaterials in 4He heavy ion therapy10.1080/10420150.2022.2153251 ↗
9. Quantification of the relative biological effectiveness for ion beam radiotherapy: Direct experimental comparison of proton and carbon ion beams and a novel approach for treatment planning10.1016/j.ijrobp.2010.05.014 ↗
10. Relative biological effectiveness for cell-killing effect on various human cell lines irradiated with heavy-ion medical accelerator in Chiba (HIMAC) carbon-ion beams10.1016/S0360-3016(00)00568-X ↗
11. Recoil Analysis for Heavy Ion Beams10.29002/asujse.1090950 ↗
12. The selective colorimetric probe based on a macrocyclic Sm(III) complex for detecting lithium ion and its performance in the psychiatric drug10.1016/j.dyepig.2019.108027 ↗
13. Kamenica, M., Kothur, R.R., Willows, A., Patel, B.A., and Cragg, P.J. (2017). Lithium ion sensors. Sensors, 17.10.3390/s17102430 ↗
14. A silicon strip detector array for energy verification and quality assurance in heavy ion therapy10.1002/mp.12736 ↗
15. Development of treatment planning for scanning irradiation at HIMAC10.1016/j.nimb.2008.02.070 ↗
16. GEANT4—A simulation toolkit10.1016/S0168-9002(03)01368-8 ↗
17. Overview of the FLUKA code10.1016/j.anucene.2014.11.007 ↗
18. PHITS—A particle and heavy ion transport code system10.1016/j.radmeas.2006.07.013 ↗
19. Rhizophora spp. as potential phantom material in medical physics applications—A review10.1016/j.radphyschem.2021.109731 ↗
20. Anthropomorphic phantoms-potential for more studies and training in radiology
21. Evaluation of Proton Therapy Accuracy Using a PMMA Phantom and PET Prediction Module10.3389/fonc.2018.00523 ↗
22. Ziegler, J.F., Biersack, J.P., and Ziegler, M.D. (2008). SRIM—The Stopping and Range of Ions in Matter, SRIM Co.
23. On the use of SRIM for Computing Radiation Damage Exposure10.1016/j.nimb.2013.05.008 ↗
24. Small-field Dosimetry Based on Reduced Graphene Oxide under MeV Helium Beam Irradiation10.1080/10420150.2020.1718137 ↗
25. Evaluation of plastic materials for range shifting range compensation and solid phantom dosimetry in carbon-ion radiotherapy10.1118/1.4795338 ↗
26. Estimation of cooling water activation in high-energy heavy ion medical accelerator10.1016/j.radphyschem.2020.109258 ↗
27. Foster, D.G., and Artur, E.D. (1982). Avarege Neutronic Properties of “Prompt” Fission Poducts, Los Alamos National Lab.10.2172/5187544 ↗
28. The skin-core morphology and structure–property relationships in injection-molded polypropylene10.1002/app.1972.070160516 ↗
29. Detecting crystallization structure evolution of polypropylene injection-molded bar induced by nucleating agent10.1002/pen.21125 ↗
30. Piorkowska, E., and Rutledge, G.C. (2013). Handbook of Polymer Crystallization, John Wiley & Sons.10.1002/9781118541838 ↗
31. Passage of particles through matter10.1007/BF02683419 ↗
32. Was, S.G. (2017). Fundamentals of Radiation Materials Science Metals and Alloys, Springer.
33. Innovative materials for fusion power plant structures: Separating functions10.1088/0953-8984/16/27/001 ↗
34. Ion-beam modification of polymeric materials fundamental principles and applications10.1016/S0168-583X(99)00129-9 ↗
35. Ziegler, J.F. (2020, March 13). SRIM: The Stopping and Range of Ion in Matter. Publisher of Website. Available online: https://www.srim.org.
36. Effect of different embolization materials on proton beam stereotactic radiosurgery Arteriovenous Malformation dose distributions using the Monte Carlo simulation code
37. Ionization and phonon production by 10B ions in radiotherapy applications
38. Charged particle radiotherapy at the Hyogo Ion Beam Medical Center: Characteristics, technology and clinical results10.2183/pjab.83.151 ↗
39. The development and clinical use of a beam on-line PET system mounted on a rotating gantry port in proton therapy10.1016/j.ijrobp.2009.05.065 ↗
40. Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy10.1016/j.ijrobp.2007.01.063 ↗
41. An experiment-based approach for predicting positron emitter distributions produced during therapeutic ion irradiation10.1109/TNS.2011.2172629 ↗
42. Depth absorbed dose and LET distributions of therapeutic H, He, Li and C beams10.1118/1.2400621 ↗
43. Toward the use of single crystal diamond based detector for ion-beam therapy microdosimetry10.1016/j.radmeas.2018.02.001 ↗
44. Intracranial stereotactic radiation therapy with charged particle beams: An opportunity to regain the momentum10.1016/j.ijrobp.2015.10.016 ↗
45. Stereotactic radiosurgery for cerebellopontine angle meningiomas10.3171/2013.11.JNS131607 ↗
46. Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon-and oxygen ion beams10.18632/oncotarget.10996 ↗