Modular Hemipelvic Prosthesis Preserves Normal Biomechanics and Showed Good Compatibility: A Finite Element Analysis
Source abstract
Abstract
This study aimed to evaluate the biomechanical compatibility of a modular hemipelvic prosthesis by comparing stress distributions between an implanted pelvis and a healthy pelvis. Finite element analysis was used to simulate bilateral standing loads on both models, analyzing critical regions such as the sacroiliac joints, iliac crest, acetabulum, and prosthesis connection points. Six models with varied displacements of the hip joint rotational center were also introduced to assess the impact of deviations on stress distribution. The implanted pelvis had a stress distribution closely matching that of the intact pelvis, indicating that the prosthesis design maintained the biomechanical integrity of the pelvis. Stress patterns in displacement models with deviations of less than 10 mm were similar to the standard model, with only minor changes in stress magnitude. However, backward, upward, and inward deviations resulted in stress concentrations, particularly in the prosthesis connection points, increasing the likelihood of mechanical failure. The modular hemipelvic prosthesis demonstrated good biomechanical compatibility with minimal impact on pelvic stress distribution, even with moderate deviations in the hip joint’s rotational center; outward, forward, and downward displacements are preferable to minimize stress concentration and prevent implant failure in cases where minor deviations in the rotational center are unavoidable during surgery.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Shoulder and Clavicle Injuries · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu 610041, China
Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, No. 37 Guoxue Road, Chengdu 610041, China
Funding
Science and Technology Research Program of Sichuan Province · QingDao Research Institutes of Sichuan University, Research of Biomedical Materials and 3D Printing Related Products
References (73)
Show source-provided references
1. Three-dimensional finite element modeling of the human external ear: Simulation study of the bone conduction occlusion effect10.1121/1.4864484 ↗
2. Use of voxel-oriented femur models for stress analysis. Generation, calculation and validation of CT-based FEM models10.1515/bmte.1995.40.6.175 ↗
3. Three-dimensional finite element analysis of the foot during standing--a material sensitivity study10.1016/j.jbiomech.2004.05.035 ↗
4. Influence of prosthesis material on stress distribution in bone and implant: A 3-dimensional finite element analysis
5. Material assignment in finite element modeling: Heterogeneous properties of the mandibular bone10.1097/SCS.0b013e31827ff137 ↗
6. Influence of crown ferrule heights and dowel material selection on the mechanical behavior of root-filled teeth: A finite element analysis10.1111/j.1532-849X.2011.00832.x ↗
7. A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries10.1016/j.ultrasmedbio.2004.04.005 ↗
8. 3D-finite element model of the human cochlea including fluid-structure couplings10.1159/000027688 ↗
9. A 3-D hp finite/infinite element method to calculate power deposition in the human head10.1109/TBME.2006.889177 ↗
10. Finite element analysis of acetabular reconstruction. Noncemented threaded cups10.3109/17453678709146499 ↗
11. Load transfer across the pelvic bone10.1016/0021-9290(94)00125-N ↗
12. Zhao, G., Wang, L., Wang, H., Li, C., Yuan, S., Sun, J., Tian, Y., and Liu, X. (2024). Biomechanical Effects of Multi-segment Fixation on Lumbar Spine and Sacroiliac Joints: A Finite Element Analysis. Orthop. Surg.10.1111/os.14187 ↗
13. Li, G., Zhang, X., Chen, M., Luo, Z., Ji, X., Pan, C., Li, H., and Shang, X.F. (2024). Bispherical metal augment improved biomechanical stability in severe acetabular deficiency reconstruction: A comparative finite element analysis. BMC Musculoskelet. Disord., 25.10.1186/s12891-024-07816-0 ↗
14. Mumtaz, M., Collins, A.P., Shekouhi, N., Varier, K., Tripathi, S., Ames, C.P., Deviren, V., Clark, A.J., Goel, V.K., and Theologis, A.A. (2024). Effects of pelvic fixation strategies and multi-rod constructs on biomechanics of the proximal junction in long thoracolumbar posterior instrumented fusions: A finite-element analysis. Spine Deform.10.1007/s43390-024-00932-w ↗
15. Finite Element Analysis of Pelvic Floor Biomechanical Models to Elucidate the Mechanism for Improving Urination and Defecation Dysfunction in Older Adults: Protocol for a Model Development and Validation Study10.2196/56333 ↗
16. Pelvic reconstruction with a combined hemipelvic prostheses after resection of primary malignant tumor10.1016/j.suronc.2009.04.003 ↗
17. Pelvic limb-salvage surgery for malignant tumors: 30 years of progress in China
18. Does Adding Femoral Lengthening at the Time of Rotation Hip Transposition After Periacetabular Tumor Resection Allow for Restoration of Limb Length and Function? Interim Results of a Modified Hip Transposition Procedure10.1097/CORR.0000000000001653 ↗
19. The use of extracorporeally irradiated autografts in pelvic reconstruction following tumour resection10.1302/0301-620X.96B10.33470 ↗
20. Long-term results of reconstruction with pelvic allografts after wide resection of pelvic sarcomas10.1155/2014/605019 ↗
21. Results of surgical resection in pelvic Ewing’s sarcoma10.1002/jso.23107 ↗
22. Liu, B., Yang, F., Zhang, T.W., Tan, J., and Yuan, Z. (2023). Clinical exploration of the international society of limb salvage classification of endoprosthetic failure using Henderson in the application of 3D-printed pelvic tumor prostheses. Front. Oncol., 13.10.3389/fonc.2023.1271077 ↗
23. Limb Salvage and Pelvic Reconstruction With Endoprosthesis After Pelvic Tumor Resection: A Narrative Review
24. Reconstruction After Hemipelvectomy With the Ice-Cream Cone Prosthesis: What Are the Short-term Clinical Results?10.1007/s11999-016-4747-x ↗
25. Acetabular reconstruction with an ice-cream cone prosthesis following resection of pelvic tumors: Does computer navigation improve surgical outcome?10.1002/jso.25882 ↗
26. Reconstruction of periacetabular tumours with saddle prosthesis or custom-made prosthesis, functional results and complications10.5301/hipint.5000306 ↗
27. Clinical and functional outcomes of the saddle prosthesis10.1007/s10195-012-0189-8 ↗
28. Comparison of reconstructive techniques after acetabular resection for pelvic chondrosarcoma10.1302/0301-620X.103B2.BJJ-2020-1012.R1 ↗
29. Biomechanical and clinical outcomes of 3D-printed versus modular hemipelvic prostheses for limb-salvage reconstruction following periacetabular tumor resection: A mid-term retrospective cohort study10.1186/s13018-024-04697-w ↗
30. Lv, Z., Li, Z., Yang, Q., and Li, J. (2023). A 3D-printed patient-specific modular implants for pelvic reconstruction of bone tumors involving the sacroiliac joint. Front. Bioeng. Biotechnol., 11.10.3389/fbioe.2023.1233960 ↗
31. The saddle prosthesis in pelvic primary and secondary musculoskeletal tumors: Functional results at several postoperative intervals10.1007/s004020050041 ↗
32. Biomechanics study of a 3D printed sacroiliac joint fixed modular hemipelvic endoprosthesis10.1016/j.clinbiomech.2020.02.014 ↗
33. Wang, M., Liu, T., Xu, C., Liu, C., Li, B., Lian, Q., Chen, T., Qiao, S., and Wang, Z. (2022). 3D-printed hemipelvic prosthesis combined with a dual mobility bearing in patients with primary malignant neoplasm involving the acetabulum: Clinical outcomes and finite element analysis. BMC Surg., 22.10.1186/s12893-022-01804-8 ↗
34. Reconstruction of type II+III pelvic resection with a modular hemipelvic endoprosthesis: A finite element analysis study10.1111/j.1757-7861.2010.00099.x ↗
35. Effects of different resection levels on biomechanics after modular hemipelvic endoprosthesisreconstruction: Finite element analysis
36. Finite element analysis of the pelvis after modular hemipelvic endoprosthesis reconstruction10.1007/s00264-012-1756-6 ↗
37. Finite element analysis and static biomechanics of pelvic after modular hemipelvic prosthesis reconstruction
38. Acrylic bone cements: Mechanical and physical properties10.1016/j.ocl.2004.06.011 ↗
39. Biomechanical study of load transfer of the pubic ramus due to pelvic inclination after hip joint surgery using a three-dimensional finite element model10.1007/s00776-004-0772-9 ↗
40. Biomechanical response of the pubic symphysis in lateral pelvic impacts: A finite element study10.1016/j.jbiomech.2007.01.023 ↗
41. Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method10.1016/j.jbiomech.2005.05.024 ↗
42. Stolk, J., Maher, S.A., Verdonschot, N., Prendergast, P.J., and Huiskes, R. (2003). Can finite element models detect clinically inferior cemented hip implants?. Clin. Orthop. Relat. Res., 138–150.10.1097/01.blo.0000058882.03274.5e ↗
43. Wang, G., Zhang, C., Xu, S., and Ren, K. (2007). Establishment of a three-dimensional finite element model of acetabulum by using DICOM data. J. Clin. Rehabil. Tissue Eng. Res., 111–114.
44. Pelvic muscle and acetabular contact forces during gait10.1016/S0021-9290(97)00041-9 ↗
45. Mechanical and textural properties of pelvic trabecular bone10.1016/0021-9290(93)90014-6 ↗
46. A physiologically based criterion for muscle force predictions on locomotion
47. Mechanical analysis of the human pelvis and its application to the artificial hip joint--by means of the three dimensional finite element method10.1016/0021-9290(83)90075-1 ↗
48. Teng, Y., Wang, Z., Li, D., Su, X., Liu, F., Huan, Y., and Gong, X. (2004). Study of custom-made prosthesis based on rapid prototyping techniqued. Orthop. J. China, 37–39.
49. Finite element model of a novel short stemmed total hip arthroplasty implant developed from cross sectional CT scans10.3233/THC-130743 ↗
50. Load-transfer analysis after insertion of cementless anatomical femoral stem using pre- and post-operative CT images based patient-specific finite element analysis10.1016/j.medengphy.2014.02.018 ↗
51. Facial mimics simulation using MRI and finite element analysis
52. Assessment of trabecular bone yield and post-yield behavior from high-resolution MRI-based nonlinear finite element analysis at the distal radius of premenopausal and postmenopausal women susceptible to osteoporosis10.1016/j.acra.2013.09.005 ↗
53. Stress distribution on dentin-cement-post interface varying root canal and glass fiber post diameters. A three-dimensional finite element analysis based on micro-CT data10.1590/1679-775720130203 ↗
54. Prediction of bone strength by μCT and MDCT-based finite-element-models: How much spatial resolution is needed?10.1016/j.ejrad.2013.10.024 ↗
55. An improved method for the automatic mapping of computed tomography numbers onto finite element models10.1016/S1350-4533(03)00138-3 ↗
56. Determination of orthotropic bone elastic constants using FEA and modal analysis10.1016/S0021-9290(02)00022-2 ↗
57. Concept and development of an orthotropic FE model of the proximal femur10.1016/S0021-9290(02)00309-3 ↗
58. Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions10.1016/j.medengphy.2005.06.003 ↗
59. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone10.1038/35015116 ↗
60. Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur10.1016/j.medengphy.2005.12.006 ↗
61. Biomechanical finite element analysis of the pelvic in a standing position following modular hemipelvic prosthesis replacement
62. A finite element analysis of the pelvic reconstruction using fibular transplantation fixed with four different rod-screw systems after type I resection10.1097/00029330-200802020-00008 ↗
63. Stress distributions in the acetabular region--I. Before and after total joint replacement10.1016/0021-9290(82)90247-0 ↗
64. Contact finite element stress analysis of the hip joint10.1002/jor.1100030406 ↗
65. Stresses in the normal pelvis10.1016/0010-4825(78)90001-X ↗
66. Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies10.1115/1.1894148 ↗
67. Finite element modelling of the pelvis: Inclusion of muscular and ligamentous boundary conditions10.1016/j.medengphy.2006.08.010 ↗
68. Function and pathomechanics of the sacroiliac joint. A review10.1093/ptj/65.1.35 ↗
69. Clinical Significance of Hip Rotation Center Location after Reconstruction with Modular Hemipelvic Prostheses for Pelvic Tumor
70. Three-dimensional finite element analysis of several internal and external pelvis fixations10.1115/1.1289995 ↗
71. Hip joint loading during walking and running, measured in two patients10.1016/0021-9290(93)90058-M ↗
72. An analysis of hip joint loading during walking, running, and skiing10.1097/00005768-199901000-00021 ↗
73. Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery10.1002/jor.1100090502 ↗