journal article·2020-11-05Open access

Mechanical Evaluation of the Stability of One or Two Miniscrews under Loading on Synthetic Bone

Andrea Pradal, Ludovica Nucci, Nicola Derton, Maria Elena De Felice, Gianluca Turco, Vincenzo Grassia, Luca Contardo

Abstract

The aim of the present study was to evaluate the primary stability of a two-miniscrew system inserted into a synthetic bone and to compare the system with the traditional one. Forty-five bi-layered polyurethane blocks were used to simulate maxillary cancellous and cortical bone densities. Samples were randomly assigned to three groups—one-miniscrew system (Group A, N = 23), two-miniscrew system (Group B, N = 22) and archwire-only (Group C, N = 10). A total of 67 new miniscrews were subdivided into Group A (23 singles) and Group B (22 couples). 30 mm of 19″ × 25″ archwires were tied to the miniscrew. The load was applied perpendicularly to the archwire. Maximum Load Value (MLV), Yield Load (YL) and Loosening Load (LL) were recorded for each group. The YL of Group B and C had a mean value respectively of 4.189 ± 0.390 N and 3.652 ± 0.064 N. The MLV of Group A, B and C had a mean value respectively of 1.871 ± 0.318N, of 4.843 ± 0.515 N and 4.150 ± 0.086 N. The LL of Group A and B had a mean value respectively of 1.871 ± 0.318 N and of 2.294 ± 0.333 N. A two- temporary anchorage device (TAD) system is on average stiffer than a one-TAD system under orthodontic loading.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · dental development and anomalies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Medical, Surgical and Health Sciences, University of Trieste, 34127 Trieste, Italy

Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, 81100 Naples, Italy

References (29)

Show source-provided references
1. Clinical use of miniscrew implants as orthodontic anchorage: Success rates and postoperative discomfort10.1016/j.ajodo.2005.02.032 ↗
2. Factors associated with the stability of mini-implants for orthodontic anchorage: A study of 414 samples in Taiwan10.1016/j.joms.2009.04.015 ↗
3. Miniscrew stability evaluated with computerized tomography scanning10.1016/j.ajodo.2008.03.024 ↗
4. Temporary anchorage device stability: An evaluation of thread shape factor10.1093/ejo/cjr026 ↗
5. Evaluations of miniscrew type-dependent mechanical stability10.1016/j.clinbiomech.2019.06.016 ↗
6. Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants10.1016/j.ajodo.2011.09.008 ↗
7. Primary stability and viscoelastic displacement of mini-implant system under loading10.1016/j.clinbiomech.2016.11.004 ↗
8. A comparitive clinical study between self tapping and drill free screws as a source of rigid orthodontic anchorage10.1007/s12663-011-0240-y ↗
9. Clinical evaluation of immediate loading of titanium orthodontic implants10.1016/j.mjafi.2012.06.020 ↗
10. Stability of miniplates and miniscrews used for orthodontic anchorage: Experience with 492 temporary anchorage devices10.1111/j.1600-0501.2008.01571.x ↗
11. Parameters affecting primary stability of orthodontic mini-implants10.1007/s00056-006-0611-z ↗
12. Failure rates and associated risk factors of orthodontic miniscrew implants: A meta-analysis10.1016/j.ajodo.2012.05.016 ↗
13. Stability of secondarily inserted orthodontic miniscrews after failure of the primary insertion for maxillary anchorage: Maxillary buccal area vs midpalatal suture area10.1016/j.ajodo.2017.05.024 ↗
14. A study of success rate of miniscrew implants as temporary anchorage devices in Singapore10.1155/2015/294670 ↗
15. Effects of predrilling depth and implant shape on the mechanical properties of orthodontic mini-implants during the insertion procedure10.2319/080911-503.1 ↗
16. “Safe Zones” for miniscrew implant placement in different dentoskeletal patterns10.2319/061710-111.1 ↗
17. Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants: A retrospective study10.1007/s00056-018-0120-x ↗
18. Torque loss after miniscrew placement: An in-vitro study followed by a clinical trial10.2174/1874210601610010251 ↗
19. The ideal insertion angle after immediate loading in Jeil, Storm, and Thunder miniscrews: A 3D-FEM study10.1016/j.ortho.2020.03.003 ↗
20. Evaluation of miniscrew angulation in the posterior maxilla using cone-beam computed tomographic image10.1590/2177-6709.23.1.046-053.oar ↗
21. Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density: Failure factors for orthodontic miniscrew10.1111/ocr.12003 ↗
22. Micro-CT evaluation of the cortical bone micro-architecture in the anterior and posterior maxilla and the maxillary sinus floor10.1007/s00784-018-2573-0 ↗
23. Can cone beam CT predict the hardness of interradicular cortical bone?10.1186/1746-160X-10-12 ↗
24. Do miniscrews remain stationary under orthodontic forces?10.1016/j.ajodo.2003.06.018 ↗
25. Influence of cortical bone thickness on miniscrew microcrack formation10.1016/j.ajodo.2016.12.028 ↗
26. Quantitative CBCT evaluation of maxillary and mandibular cortical bone thickness and density variability for orthodontic miniplate placement
27. Mandibular molar uprighting using mini-implants: Different approaches for different clinical cases—Two case reports
28. Mg bone implant: Features, developments and perspectives10.1016/j.matdes.2019.108259 ↗
29. Evaluation of the implant stability and the marginal bone level changes during the first three months of dental implant healing process: A prospective clinical study10.1016/j.jmbbm.2020.103899 ↗