journal article·2022-11-16Open access

Effect of Silicon Carbide Coating on Osteoblast Mineralization of Anodized Titanium Surfaces

Patricia dos Santos Calderon, Fernanda Regina Godoy Rocha, Xinyi Xia, Samira Esteves Afonso Camargo, Ana Luisa de Barros Pascoal, Chan-Wen Chiu, Fan Ren, Steve Ghivizzani, Josephine F. Esquivel-Upshaw

Abstract

The objective of this study was to evaluate the influence of the titanium nanotube diameter and the effect of silicon carbide (SiC) coating on the proliferation and mineralization of pre-osteoblasts on titanium nanostructured surfaces. Anodized titanium sheets with nanotube diameters of 50 and 100 nm were used. The following four groups were tested in the study: (1) non-coated 50 nm nanotubes; (2) SiC-coated 50 nm titanium nanotubes; (3) non-coated 100 nm nanotubes and (4) SiC-coated 100 nm nanotubes. The biocompatibility and cytotoxicity of pre-osteoblasts were evaluated using a CellTiter-BlueCell Viability assay after 1, 2, and 3 days. After 3 days, cells attached to the surface were observed by SEM. Pre-osteoblast mineralization was determined using Alizarin-Red staining solution after 21 days of cultivation. Data were analyzed by a Kruskal–Wallis test at a p-value of 0.05. The results evidenced biocompatibility and non-cytotoxicity of both 50 and 100 nm diameter coated and non-coated surfaces after 1, 2 and 3 days. The statistical analysis indicates a statistically significant higher cell growth at 3 days (p < 0.05). SEM images after 3 days demonstrated flattened-shaped cells without any noticeable difference in the phenotypes between different diameters or surface treatments. After 21 days of induced osteogenic differentiation, the statistical analysis indicates significantly higher osteoblast calcification on coated groups of both diameters when compared with non-coated groups (p < 0.05). Based on these results, we can conclude that the titanium nanotube diameter did not play any role on cell viability or mineralization of pre-osteoblasts on SiC-coated or non-coated titanium nanotube sheets. The SiC coating demonstrated biocompatibility and non-cytotoxicity and contributed to an increase in osteoblast mineralization on titanium nanostructured surfaces when compared to non-coated groups.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dentistry, Federal University of Rio Grande do Norte, Natal 59056, RN, Brazil

Department of Oral Biology, University of Florida College of Dentistry, Gainesville, FL 32610, USA

Department of Chemical Engineering, University of Florida, Gainesville, FL 32611, USA

Department of Comprehensive Oral Healthy, Adams Dental School, University of North Carolina, Chapel Hill, NC 27599, USA

Department of Orthopaedic Surgery and Sports Medicine, College of Medicine, University of Florida, Gainesville, FL 32607, USA

Department of Restorative Dental Sciences, Division of Prosthodontics, College of Dentistry, University of Florida, Gainesville, FL 32610, USA

Funding

National Institutes of Health-NIDCR · Coordenação de Aperfeicoamento de Pessoal de Nível Superior—Brasil (CAPES)

References (34)

Show source-provided references
1. Osseointegrated Titanium Implants: Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in Man10.3109/17453678108991776 ↗
2. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
3. Effects of implant surface coatings and composition on bone integration: A systematic review10.1111/j.1600-0501.2009.01777.x ↗
4. Effects of titanium nanotubes on the osseointegration, cell differentiation, mineralisation and antibacterial properties of orthopaedic implant surfaces10.1302/0301-620X.100B1.BJJ-2017-0551.R1 ↗
5. Effects of titanium-based nanotube films on osteoblast behavior in vitro10.1002/jbm.a.35148 ↗
6. In vitro evaluation of osteoblast responses to carbon nanotube-coated titanium surfaces10.1186/s40510-016-0136-y ↗
7. Camargo, S.E.A., Roy, T., Iv, P.H.C., Fares, C., Ren, F., Clark, A.E., and Esquivel-Upshaw, J.F. (2020). Novel Coatings to Minimize Bacterial Adhesion and Promote Osteoblast Activity for Titanium Implants. J. Funct. Biomater., 11.10.3390/jfb11020042 ↗
8. Camargo, S.E.A., Xia, X., Fares, C., Ren, F., Hsu, S.-M., Budei, D., Aravindraja, C., Kesavalu, L., and Esquivel-Upshaw, J.F. (2021). Nanostructured Surfaces to Promote Osteoblast Proliferation and Minimize Bacterial Adhesion on Titanium. Materials, 14.10.3390/ma14164357 ↗
9. Zhao, X., Wang, T., Qian, S., Liu, X., Sun, J., and Li, B. (2016). Silicon-Doped Titanium Dioxide Nanotubes Promoted Bone Formation on Titanium Implants. Int. J. Mol. Sci., 17.10.3390/ijms17030292 ↗
10. Different diameters of titanium dioxide nanotubes modulate Saos-2 osteoblast-like cell adhesion and osteogenic differentiation and nanomechanical properties of the surface10.1039/C9RA00761J ↗
11. Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface10.1016/j.actbio.2009.05.008 ↗
12. Epidemiology and risk factors of peri-implantitis: A systematic review10.1111/jre.12562 ↗
13. Effectiveness of Implant Therapy Analyzed in a Swedish Population10.1177/0022034515608832 ↗
14. Soler, M.D., Hsu, S.-M., Fares, C., Ren, F., Jenkins, R.J., Gonzaga, L., Clark, A.E., O’Neill, E., Neal, D., and Esquivel-Upshaw, J.F. (2020). Titanium Corrosion in Peri-Implantitis. Materials, 13.10.3390/ma13235488 ↗
15. Increased Levels of Dissolved Titanium Are Associated with Peri-Implantitis—A Cross-Sectional Study10.1902/jop.2016.160524 ↗
16. Hsu, S.-M., Ren, F., Chen, Z., Kim, M., Fares, C., Clark, A.E., Neal, D., and Esquivel-Upshaw, J.F. (2020). Novel Coating to Minimize Corrosion of Glass-Ceramics for Dental Applications. Materials, 13.10.3390/ma13051215 ↗
17. Fares, C., Hsu, S.-M., Xian, M., Xia, X., Ren, F., Mecholsky, J.J.J., Gonzaga, L., and Esquivel-Upshaw, J. (2020). Demonstration of a SiC Protective Coating for Titanium Implants. Materials, 13.10.3390/ma13153321 ↗
18. Camargo, S.E.A., Roy, T., Xia, X., Fares, C., Hsu, S.-M., Ren, F., Clark, A.E., Neal, D., and Esquivel-Upshaw, J.F. (2021). Novel Coatings to Minimize Corrosion of Titanium in Oral Biofilm. Materials, 14.10.3390/ma14020342 ↗
19. Afonso Camargo, S.E., Mohiuddeen, A.S., Fares, C., Partain, J.L., Carey, P.H., Ren, F., Hsu, S.-M., Clark, A.E., and Esquivel-Upshaw, J.F. (2020). Anti-Bacterial Properties and Biocompatibility of Novel SiC Coating for Dental Ceramic. J. Funct. Biomater., 11.10.3390/jfb11020033 ↗
20. Esquivel-Upshaw, J.F., Ren, F., and Camargo, S.C.A.E. (2020). Methods And Compositions For Medical Implants Having Anti-Bacterial Coatings, U.S.P.T. Office.
21. Esquivel-Upshaw, J.F., Ren, F., Clark, A.E., and Batich, C.C.P. (2018). Quaternized TiN Anti-Bacterial Coating for Dental Implants, U.S.P.T. Office.
22. Hsu, S.-M., Ren, F., Batich, C.D., Clark, A.E., Neal, D., and Esquivel-Upshaw, J.F. (2020). Effect of pH Cycling Frequency on Glass–Ceramic Corrosion. Materials, 13.10.3390/ma13163655 ↗
23. Silicon: A Possible Factor in Bone Calcification10.1126/science.167.3916.279 ↗
24. Enhanced early osteogenic differentiation by silicon-substituted hydroxyapatite ceramics fabricated via ultrasonic spray pyrolysis route10.1007/s10856-012-4744-x ↗
25. Enhanced osteoblast functions on anodized titanium with nanotube-like structures10.1002/jbm.a.31551 ↗
26. Hsu, S.M., Fares, C., Xia, X., Rasel, M.A.J., Ketter, J., Camargo, S.E.A., Haque, M.A., Ren, F., and Esquivel-Upshaw, J. (2021). In vitro corrosion of SiC-coated anodized Ti nano-tubular surfaces. Funct. Biomater, 12.10.3390/jfb12030052 ↗
27. Biocompatibility Issues with Modern Implants in Bone-A Review for Clinical Orthopedics10.2174/1874325000802010066 ↗
28. Binding of plasma proteins to titanium dioxide nanotubes with different diameters
29. The role of TiO 2 nanotube surface on osseointegration of titanium implants: Biomechanical and histological study in rats10.1002/jemt.23473 ↗
30. Enhanced Performance of Osteoblasts by Silicon Incorporated Porous TiO2 Coating10.1016/S1005-0302(12)60030-9 ↗
31. Thermal treatment to increase titanium wettability induces selective proteins adsorption from blood serum thus affecting osteoblasts adhesion10.1016/j.msec.2019.110250 ↗
32. Osteoblast adhesion and response mediated by terminal –SH group charge surface of SiOxCy nanowires10.1007/s10856-019-6241-y ↗
33. The enhanced modulation of key bone matrix components by modified Titanium implant surfaces10.1016/j.bone.2011.07.040 ↗
34. Fares, C., Elhassani, R., Partain, J., Hsu, S.M., Cracium, V., Ren, F., and Esquivel-Upshaw, J. (2020). Anneling and N2 plasma treatment to minimize corrosion of SiC-coated glass-ceramics. Materials, 13.10.3390/ma13102375 ↗