journal article·2018-12-04Open access

Microfluidic Deformability Study of an Innovative Blood Analogue Fluid Based on Giant Unilamellar Vesicles

Denise A. M. Carvalho, Ana Rita O. Rodrigues, Vera Faustino, Diana Pinho, Elisabete M. S. Castanheira, Rui Lima

Abstract

Blood analogues have long been a topic of interest in biofluid mechanics due to the safety and ethical issues involved in the collection and handling of blood samples. Although the current blood analogue fluids can adequately mimic the rheological properties of blood from a macroscopic point of view, at the microscopic level blood analogues need further development and improvement. In this work, an innovative blood analogue containing giant unilamellar vesicles (GUVs) was developed to mimic the flow behavior of red blood cells (RBCs). A natural lipid mixture, soybean lecithin, was used for the GUVs preparation, and three different lipid concentrations were tested (1 × 10−3 M, 2 × 10−3 M and 4 × 10−3 M). GUV solutions were prepared by thin film hydration with a buffer, followed by extrusion. It was found that GUVs present diameters between 5 and 7 µm which are close to the size of human RBCs. Experimental flow studies of three different GUV solutions were performed in a hyperbolic-shaped microchannel in order to measure the GUVs deformability when subjected to a homogeneous extensional flow. The result of the deformation index (DI) of the GUVs was about 0.5, which is in good agreement with the human RBC’s DI. Hence, the GUVs developed in this study are a promising way to mimic the mechanical properties of the RBCs and to further develop particulate blood analogues with flow properties closer to those of real blood.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Rheology and Fluid Dynamics Studies · Blood properties and coagulation · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Microelectromechanical Systems Research Unit (CMEMS-UMinho), DEI, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal

Centre of Physics, University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal

MEtRICs, Mechanical Engineering Department, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal

CEFT, Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal

Research Centre in Digitalization and Intelligent Robotics (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal

Funding

Fundação para a Ciência e a Tecnologia

References (33)

Show source-provided references
1. Extensional flow of blood analog solutions in microfluidic devices10.1063/1.3567888 ↗
2. A review of hemorheology: Measuring techniques and recent advances10.1007/s13367-016-0001-z ↗
3. A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs10.1046/j.1525-1594.1999.06316.x ↗
4. Ghost Cell Suspensions as Blood Analogue Fluid for Macroscopic Particle Image Velocimetry Measurements10.1111/aor.12511 ↗
5. Calejo, J., Pinho, D., Galindo-Rosales, F.J., Lima, R., and Campo-Deaño, L. (2016). Particulate blood analogues reproducing the erythrocytes cell-free layer in a microfluidic device containing a hyperbolic contraction. Micromachines, 7.10.3390/mi7010004 ↗
6. Generation of micro-sized PDMS particles by a flow focusing technique for biomicrofluidics applications10.1063/1.4943007 ↗
7. Shrinkage and colour in the production of micro-sized PDMS particles for microfluidic applications10.1088/1361-6439/aab7b9 ↗
8. A Method for Matching the Refractive Index and Kinematic Viscosity of a Blood Analog for Flow Visualization in Hydraulic Cardiovascular Models10.1115/1.1785812 ↗
9. Dynamic scaling of unsteady shear-thinning non-Newtonian fluid flows in a large-scale model of a distal anastomosis10.1007/s00348-007-0317-z ↗
10. Flow visualization for different port angles of a pulsatile ventricular assist device10.1007/s10047-011-0614-4 ↗
11. Flow of a blood analogue fluid in a compliant abdominal aortic aneurysm model: Experimental modelling10.1016/j.jbiomech.2014.02.026 ↗
12. The superposition of steady on oscillatory shear and its effect on the viscoelasticity of human blood and a blood-like model fluid10.3233/BIR-1997-34102 ↗
13. A rapid and low-cost nonlithographic method to fabricate biomedical microdevices for blood flow analysis10.3390/mi6010121 ↗
14. Red blood cells radial dispersion in blood flowing through microchannels: The role of temperature10.1016/j.jbiomech.2015.11.037 ↗
15. In vitro particulate analogue fluids for experimental studies of rheological and hemorheological behavior of glucose-rich RBCs suspensions10.1063/1.4998190 ↗
16. Effect of Surfactants in Soybean Lecithin Liposomes studied by Energy Transfer between NBD-PE and N-Rh-PE10.3109/08982100009031108 ↗
17. A membrane filtering method for the purification of giant unilamellar vesicles10.1016/j.chemphyslip.2011.04.003 ↗
18. Preparing giant unilamellar vesicles (GUVs) of complex lipid mixtures on demand: Mixing small unilamellar vesicles of compositionally heterogeneous mixtures10.1016/j.bbamem.2015.09.020 ↗
19. Approaches to the study of Atg8-mediated membrane dynamics in vitro10.1016/B978-0-12-386487-1.00005-5 ↗
20. Stability of giant unilamellar vesicles and large unilamellar vesicles of liquid-ordered phase membranes in the presence of Triton X-10010.1016/j.bbamem.2004.09.004 ↗
21. Bento, D., Rodrigues, R.O., Faustino, V., Pinho, D., Fernandes, C.S., Pereira, A.I., Garcia, V., Miranda, J.M., and Lima, R. (2018). Deformation of Red Blood Cells, Air Bubbles, and Droplets in Microfluidic Devices: Flow Visualizations and Measurements. Micromachines, 9.10.3390/mi9040151 ↗
22. Extensional flow-based assessment of red blood cell deformability using hyperbolic converging microchannel10.1007/s10544-009-9319-3 ↗
23. Haemocompatibility of iron oxide nanoparticles synthesized for theranostic applications: A high-sensitivity microfluidic tool10.1007/s11051-016-3498-7 ↗
24. A simple microfluidic device for the deformability assessment of blood cells in a continuous flow10.1007/s10544-015-0014-2 ↗
25. Viscoelasticity of blood and viscoelastic blood analogues for use in polydymethylsiloxane in vitro models of the circulatory system10.1063/1.4804649 ↗
26. Flow of a Blood Analogue Solution Through Microfabricated Hyperbolic Contractions10.1007/978-94-007-0011-6_15 ↗
27. Microfluidic diffusive filter for apheresis (leukapheresis)10.1039/B512049G ↗
28. Recent advances in microfluidic techniques for single cell biophysical characterization10.1039/c3lc50355k ↗
29. Shape and Biomechanical Characteristics of Human Red Blood Cells in Health and Disease10.1557/mrs2010.571 ↗
30. Thermotropic Phase Transitions of Pure Lipids in Model Membranes and Their Modifications by Membrane Proteins
31. The structural role of cholesterol in cell membranes: From condensed bilayers to lipid rafts10.1021/ar500260t ↗
32. Influence of Cholesterol on the Phase Transition of Lipid Bilayers: A Temperature-Controlled Force Spectroscopy Study10.1021/la302620t ↗
33. Magnetic properties of nanoparticles as a function of their spatial distribution on liposomes and cells10.1039/C8CP03016B ↗