Debris Evaluation after Root Canal Shaping with Rotating and Reciprocating Single-File Systems
Source abstract
Abstract
This study evaluated the root canal dentine surface by scanning electron microscope (SEM) after shaping with two reciprocating single-file NiTi systems and two rotating single-file NiTi systems, in order to verify the presence/absence of the smear layer and the presence/absence of open tubules along the walls of each sample; Forty-eight single-rooted teeth were divided into four groups and shaped with OneShape (OS), F6 SkyTaper (F6), WaveOne (WO) and Reciproc and irrigated using 5.25% NaOCl and 17% EDTA. Root canal walls were analyzed by SEM at a standard magnification of 2500×. The presence/absence of the smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05; The Kruskal-Wallis ANOVA for debris score showed significant differences among the NiTi systems (P < 0.05). The Mann-Whitney test confirmed that reciprocating systems presented significantly higher score values than rotating files. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples; Single-use NiTi systems used in continuous rotation appeared to be more effective than reciprocating instruments in leaving clean walls. The reciprocating systems produced more debris and smear layer than rotating instruments.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Drilling and Well Engineering · Dental Radiography and Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Clinical Surgical Diagnostic and Pediatric Sciences, Section of Dentistry, University of Pavia, Piazzale Golgi 3, Pavia 27100, Italy
Department of Brain and Behavioral Sciences, University of Pavia, Piazzale Golgi 3, Pavia 27100, Italy
References (33)
Show source-provided references
1. Torabinejad, M., and Walton, R.E. (2009). Endodontics: Principles and Practice, Saunders Elsevier. [4th ed.].
2. The effectiveness of four clinical irrigation methods on the removal of root canal debris10.1016/0030-4220(82)90103-7 ↗
3. Efficacy of different irrigation methods and concentrations of root canal irrigation solutions on bacteria in the root canal10.1111/j.1600-9657.1992.tb00218.x ↗
4. Antimicrobial effect of six endodontic sealers: An in vitro evaluation10.1111/j.1600-9657.1999.tb00748.x ↗
5. Antimicrobial activity of endodontic sealers on Enterococcus faecalis10.1097/00004770-200304000-00006 ↗
6. An in vitro evaluation of the particle flotation capability of various irrigating solutions
7. Antibacterial effects of endodontic irrigants on black-pigmented gramnegative anaerobes and facultative bacteria10.1016/S0099-2399(98)80023-X ↗
8. A comparison of 2.0% chlorhexidine gluconate and 5.25% sodium hypochlorite as antimicrobial endodontic irrigants10.1016/S0099-2399(06)80815-0 ↗
9. Microbiologic analysis of teeth with failed endodontic treatment and the outcome of conservative re-treatment10.1016/S1079-2104(98)90404-8 ↗
10. An evaluation of the action of different root canal irrigants on facultative aerobicanaerobic, obligate anaerobic, and microaerophilic bacteria10.1016/S0099-2399(06)81170-2 ↗
11. In vitro antimicrobial efficacy of MTAD and sodium hypochlorite10.1097/00004770-200307000-00006 ↗
12. Comparison of root canal preparation with two rotary NiTi instruments: ProFile. 04 and GT rotary10.1111/j.1365-2591.2007.01270.x ↗
13. Influence of the NiTi rotary system on the debridement quality of the root canal space10.1016/j.tripleo.2009.05.012 ↗
14. A retrospective study of endodontic treatment outcome between nickel-titanium rotary and stainless steel hand fi ling techniques10.1016/j.joen.2009.04.016 ↗
15. Antimicrobial and toxic effects of established and potential root canal irrigants10.1016/S0099-2399(06)80524-8 ↗
16. The bactericidal efficiency of sodium hypochlorite as an endodontic irrigant10.1016/0030-4220(70)90473-1 ↗
17. The solvent action of sodium hypochlorite on fixed and unfixed necrotic tissue10.1016/0030-4220(79)90281-0 ↗
18. The use of sodium hypochlorite as a general endodontic medicament10.1111/j.1365-2591.1982.tb01265.x ↗
19. Bacteriologic evaluation of the effect of 0.5 percent sodium hypochlorite in endodontic therapy10.1016/0030-4220(83)90333-X ↗
20. Antibacterial effects of various endodontic irrigants on selected anaerobic bacteria10.1111/j.1600-9657.1993.tb00258.x ↗
21. Evaluation of the effectiveness of sodium hypochlorite used with three irrigation methods in the elimination of Enterococcus faecalis from the root canal, in vitro10.1046/j.1365-2591.1997.00096.x ↗
22. The effects of sodium hypochlorite and calcium hydroxide on tissue dissolution and root canal cleanliness10.1046/j.1365-2591.1997.00085.x ↗
23. Current challenges and concepts in the preparationof root canal systems: A review10.1097/01.DON.0000129039.59003.9D ↗
24. Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: A comparative SEM investigation10.1016/S0099-2399(97)80410-4 ↗
25. Single file Ni-Ti rotary systems
26. A comparative evaluation of smear layer removal using two rotary instrument systems with ethylenediaminetetraacetic acid in different states: A SEM study10.4103/0970-9290.79967 ↗
27. SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments10.1111/j.1365-2591.2004.00887.x ↗
28. Evolution of nickel-titanium instruments: From past to future10.1111/etp.12049 ↗
29. Fifth-generation technology in endodontic: The shaping movement
30. Suboptimal debridement quality produced by the single-file F2 ProTaper technique in oval-shaped canals10.1016/j.joen.2010.08.009 ↗
31. Reciprocating root canal technique induces greater debris accumulation than a continuous rotary technique as assessed by 3-dimensional micro-computed tomography10.1016/j.joen.2013.04.003 ↗
32. Quantitative evaluation of apically extruded debris with different single-fi le systems: Reciproc, F360 and oneshape versus Mtwo10.1111/iej.12161 ↗
33. Hard-tissue debris accumulation analysis by high-resolution computed tomography scans10.1016/j.joen.2009.04.026 ↗