In this study, a porous oxide layer was formed on the surface of 316L stainless steel (SS) by combining Ti magnetron sputtering and plasma electrolytic oxidation (PEO) with the aim to produce a polymer-free drug carrier for drug eluting stent (DES) applications. The oxidation was performed galvanostatically in Na3PO4 electrolyte. The surface porosity, average pore size and roughness varied with PEO treatment duration, and under optimum conditions, the surface showed a porosity of 7.43%, an average pore size of 0.44 µm and a roughness (Ra) of 0.34 µm. The EDS analyses revealed that the porous layer consisted of Ti, O and P. The cross-sectional morphology evidenced a double-layer structure, with a porous titania surface and an un-oxidized dense Ti film towards the interface with 316L SS. After the PEO treatment, wettability and surface free energy increased significantly. The results of the present study confirm the feasibility of forming a porous TiO2 layer on stainless steel by combining sputtering technology and PEO. Further, the resultant porous oxide layer has the potential to be used as a drug carrier for DES, thus avoiding the complications associated with the polymer based carriers.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Anodic Oxide Films and Nanostructures · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of BioMechanical Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, The Netherlands
References (36)
Show source-provided references
1. Drug-eluting stents: Results, promises and problems10.1016/j.ijcard.2004.01.021 ↗
2. The future of drug eluting stents10.1016/j.phrs.2008.01.012 ↗
3. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization10.1056/NEJMoa012843 ↗
4. A polymer based, paclitaxel-eluting stent in patients with coronary artery disease10.1056/NEJMoa032441 ↗
5. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy10.1016/S0140-6736(04)17275-9 ↗
6. Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent subsequently10.7326/0003-4819-143-5-200509060-00119 ↗
7. Prevention of restenosis by novel drug-eluting stent system with a dose-adjustable, polymer-free, on-site sent coating10.1093/eurheartj/ehi405 ↗
8. In vivo investigation of blood compatibility of titanium oxide films10.1002/(SICI)1097-4636(199810)42:1<128::AID-JBM16>3.0.CO;2-H ↗
9. Titanium and titanium alloys
10. Preparation of a drug-eluting stent using a TiO2 film deposited by plasma enhanced chemical vapour deposition as a drug-combining matrix10.1039/b925409a ↗
11. Oxidized aluminum coatings on steel produced by microarc method
12. PEO protective coatings on inner surface of tubes10.1016/j.surfcoat.2006.09.056 ↗
13. Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications10.1016/S0142-9612(03)00560-X ↗
14. Plasma electrolysis for surface engineering10.1016/S0257-8972(99)00441-7 ↗
15. Fatigue response of porous coated titanium biomedical alloys10.1016/j.scriptamat.2009.03.017 ↗
16. An electron microscopical study on the growth of TiO2-Ag antibacterial coatings on Ti6Al7Nb biomedical alloy10.1016/j.actbio.2011.02.037 ↗
17. Real-time imaging of coating growth during plasma electrolytic oxidation of titanium10.1016/j.electacta.2007.08.074 ↗
18. Pore formation during the breakdown process in anodic Ta2O5 fims10.1016/0013-4686(87)87028-7 ↗
19. Evaluation of electrical breakdown of anodic films on titanium in phosphate-base solutions10.1016/j.surfcoat.2004.01.003 ↗
20. Microstructure evolution during plasma electrolytic oxidation and its effects on the electrochemical properties of AZ91D Mg alloy10.1149/1.3604947 ↗
21. Growth, microstructure and mechanical properties of microarc oxidation coatings on titanium alloy in phosphate-containing solution10.1016/j.apsusc.2004.03.231 ↗
22. Properties of coatings formed on titanium by plasma electrolytic oxidation in a phosphate-borate electrolyte10.1134/S1070427210040178 ↗
23. Frequency response studies for the plasma electrolytic oxidation process10.1016/j.surfcoat.2007.04.044 ↗
24. Mechanisms underlying the formation of thick alumina coatings through the MAO coating technology10.1016/S0257-8972(02)00918-0 ↗
25. Characterization of sparks-anodized titanium for biomedical applications10.1149/1.2717383 ↗
26. Characterization of hydroxyapatite and titanium coatings sputtered on Ti-6Al-4V substrate10.1002/(SICI)1097-4636(19990305)44:3<266::AID-JBM5>3.0.CO;2-4 ↗
27. Mechanical properties of titania prepared by plasma electrolytic oxidation at different voltages10.1016/j.surfcoat.2006.07.137 ↗
28. Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: Comparison of BiodivYsio, Taxus and Cypher stents
29. Preparation of a biocompatible stent surface by plasma polymerization followed by chemical grafting of drug compounds10.1039/b813357c ↗
30. Evaluation of ion release, cytotoxicity, and platelet adhesion of electrochemical anodized 316L stainless steel cardiovascular stents10.1002/jbm.b.31144 ↗
31. Collidal protein solutions as a new standard sensor for adhesive wettability measurements10.1006/jcis.1999.6153 ↗
32. Effect of surface treatment on the bioactivity of nickel-titanium10.1016/j.actbio.2008.05.010 ↗
33. In vitro assessment of interaction of blood with model surfaces: Acrylates and methacrylates10.1016/0021-9797(81)90413-6 ↗
34. Globular proteins at solid/liquid interface10.1016/0927-7765(94)80066-9 ↗
35. Influence of surface microroughness by plasma deposition and chemical erosion followed by TiO2 coating upon anticoagulation, hydrophilicity, and corrosion resistance of NiTi alloy stent10.1002/jbm.a.31364 ↗
36. Improved hemocompatibility guided by pulsed plasma tailoring the surface amino functionalities of TiO2 coating for covalent immobilization of heparin10.1002/ppap.201000101 ↗