journal article·2025-11-29Open access

Fracture Load of Polyaryletherketone for 4-Unit Posterior Fixed Dental Prostheses: An In Vitro Study

Dalea M. Bukhary, Hasan Y. Asiri, Ruwaida Z. Alshali, Walaa A. Babaeer, Thamer Y. Marghalani, Ghadeer I. Basunbul, Osama A. Qutub

Journal of Functional Biomaterials· Volume 16· Issue 12

Abstract

Background/Objectives: This study aimed to evaluate the mechanical properties, particularly the fracture load, modulus of elasticity, and fracture patterns, of four-unit posterior tooth-supported fixed dental prostheses (FDPs) fabricated from various computer-aided design/computer-aided manufacturing (CAD-CAM) materials. Understanding the mechanical behavior of these materials is crucial for optimizing prosthesis performance in high-load-bearing posterior regions. Methods: A total of 68 standardized FDP frameworks were fabricated, each consisting of two abutments (first premolar and second molar) and two pontics (second premolar and first molar). The specimens were divided into four groups (n = 17): polyetheretherketone (PEEK), polyetherketoneketone (PEKK), 3Y zirconia (control 1), and 4Y zirconia (control 2). All samples underwent three-point bending tests using a universal testing machine with a crosshead speed of 0.5 mm/min. Fracture patterns were assessed visually and documented. Fractured specimens were examined using scanning electron microscopy (SEM). Data were analyzed using the SPSS v20. Normality was assessed with the Shapiro–Wilk test. The fracture loads were compared using the Kruskal–Wallis test with Bonferroni correction, and the modulus of elasticity was analyzed via a one-way ANOVA with Dunnett’s T3 post hoc test. A significance level of α = 0.05 was applied. Results: Significant differences were observed among the groups. The 3Y zirconia demonstrated the highest fracture load (2275 ± 511.03 N), followed by the 4Y zirconia (1034.28 ± 221.55 N), PEEK (883.21 ± 172.24 N), and PEKK (402.01 ± 127.98 N). PEEK showed ductile fracture behavior, while PEKK exhibited brittle failure. Both zirconia groups demonstrated brittle fracture patterns. Conclusions: PEEK and 4Y zirconia presented comparable fracture loads, but with differing fracture behaviors—ductile in PEEK and brittle in 4Y zirconia. The 3Y zirconia offered the highest fracture load, but with limited flexibility. PEKK showed the lowest mechanical performance. These findings highlight the importance of material selection for FDPs in posterior load-bearing areas, considering both fracture load and failure mode.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Scientific and Engineering Research Topics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia

Funding

Deanship of Scientific Research (DSR), King Abdulaziz University, Jeddah

References (39)

Show source-provided references
1. Finite Element Analysis of Three- and Four-Unit Bridges10.1111/j.1365-2842.1989.tb01384.x ↗
2. Rosenstiel, S.F. (2022). Contemporary Fixed Prosthodontics, Elsevier. [6th ed.].
3. Three-Unit Reinforced Polyetheretherketone Composite FDPs: Influence of Fabrication Method on Load-Bearing Capacity and Failure Types10.4012/dmj.2013-345 ↗
4. Rexhepi, I., Santilli, M., D’Addazio, G., Tafuri, G., Manciocchi, E., Caputi, S., and Sinjari, B. (2023). Clinical Applications and Mechanical Properties of CAD-CAM Materials in Restorative and Prosthetic Dentistry: A Systematic Review. J. Funct. Biomater., 14.10.20944/preprints202307.1226.v1 ↗
5. The Glossary of Prosthodontic Terms: Ninth Edition10.1016/j.prosdent.2016.12.001 ↗
6. Kim, M.J., Choi, Y.J., Kim, S.K., Heo, S.J., and Koak, J.Y. (2017). Marginal Accuracy and Internal Fit of 3D Printing Laser-Sintered Co–Cr Alloy Copings. Materials, 10.10.3390/ma10010093 ↗
7. Accuracy Evaluation of Metal Copings Fabricated by Computer-Aided Milling and Direct Metal Laser Sintering Systems10.4047/jap.2015.7.2.122 ↗
8. Shillingburg, H.T., Sather, D.A., Wilson, E.L., Cain, J.R., and Mitchell, D.L. (2012). Fundamentals of Fixed Prosthodontics, Quintessence Publishing. [4th ed.].
9. Mechanical Analysis of Three-Unit Metal-Free Fixed Dental Prostheses Produced in Different Materials with CAD/CAM Technology10.1007/s00784-022-04623-6 ↗
10. Rodriguez, V., Tobar, C., Lopez-Suarez, C., Pelaez, J., and Suarez, M.J. (2021). Fracture Load of Metal, Zirconia, and Polyetheretherketone Posterior CAD–CAM Milled Fixed Partial Denture Frameworks. Materials, 14.10.3390/ma14040959 ↗
11. Flexural Behavior of PEEK Materials for Dental Application10.1016/j.dental.2015.08.151 ↗
12. Internal and Marginal Fit of Cobalt–Chromium Fixed Dental Prostheses Fabricated with Three Different Techniques10.1016/j.prosdent.2015.05.007 ↗
13. Comparative in vitro study on biomechanical behavior of zirconia and polyetheretherketone biomaterials exposed to experimental loading conditions in a prototypal simulator10.7150/ijms.82297 ↗
14. Load bearing capability of three-units 4Y-TZP monolithic fixed dental prostheses: An innovative model for reliable testing10.1016/j.matdes.2023.111751 ↗
15. Fracture resistance of three-unit fixed dental prostheses fabricated with milled and 3D-printed composite-based materials10.5005/jp-journals-10024-3137 ↗
16. Polyetherketoneketone (PEKK): An Emerging Biomaterial for Oral Implants and Dental Prostheses10.1016/j.jare.2020.09.004 ↗
17. Comprehensive Review of Polyetheretherketone Use in Dentistry10.2186/jpr.JPR_D_24_00142 ↗
18. Matyjaszewski, K., and Möller, M. (2012). Polymer Science: A Comprehensive Reference, Elsevier.
19. Effect of Connector Design on Fracture Resistance of Zirconia All-Ceramic Fixed Partial Dentures10.2209/tdcpublication.52.61 ↗
20. Alsadon, O., Wood, D., Patrick, D., and Pollington, S. (2020). Fatigue Behavior and Damage Modes of High-Performance Polyetherketoneketone (PEKK) Bilayered Crowns. J. Mech. Behav. Biomed. Mater., 110.10.1016/j.jmbbm.2020.103957 ↗
21. Fracture Load of Metal–Ceramic, Monolithic, and Bi-Layered Zirconia-Based Posterior Fixed Dental Prostheses after Thermo-Mechanical Cycling10.1016/j.jdent.2018.04.012 ↗
22. Maximising the Fracture Resistance of Dentine-Bonded All-Ceramic Crowns10.1016/S0300-5712(98)00050-5 ↗
23. Morphology and structure characterization of ceramic granules10.1016/j.jeurceramsoc.2020.04.044 ↗
24. Effect of granule morphology on breakage behaviour during compression10.1016/j.powtec.2004.04.032 ↗
25. Fragmentation and granular transition of ceramics for high rate loading10.1111/jace.18372 ↗
26. Kurtz, S.M. (2020). High-Performance Polymers for Biomedical Applications, Elsevier.
27. Paszkiewicz, S., Lesiak, P., Walkowiak, K., Irska, I., Miądlicki, K., Królikowski, M., Piesowicz, E., and Figiel, P. (2023). The Mechanical, Thermal, and Biological Properties of Materials Intended for Dental Implants: A Comparison of Three Types of Poly(Aryl-Ether-Ketones) (PEEK and PEKK). Polymers, 15.10.3390/polym15183706 ↗
28. A Sneak Peek Toward Polyaryletherketone (PAEK) Polymer: A Review
29. Arellano Moncayo, A.M., Peñate, L., Arregui, M., Giner-Tarrida, L., and Cedeño, R. (2023). State of the art of different zirconia materials and their indications according to evidence-based clinical performance: A narrative review. Dent. J., 11.10.3390/dj11010018 ↗
30. Assessing flexural strength degradation of new cubic-containing zirconia materials10.5005/jp-journals-10024-2762 ↗
31. Hajaj, T., Lile, I.E., Veja, I., Titihazan, F., Rominu, M., Negruțiu, M.L., Sinescu, C., Novac, A.C., Talpos Niculescu, S., and Zaharia, C. (2025). Influence of Pontic Length on the Structural Integrity of Zirconia Fixed Partial Dentures (FPDs). J. Funct. Biomater., 16.10.3390/jfb16040116 ↗
32. The Fracture Resistance of All-Ceramic Crowns on Supporting Structures with Different Elastic Moduli
33. Sadeqi, H.A., Baig, M.R., and Al-Shammari, M. (2021). Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems. Materials, 14.10.3390/ma14216346 ↗
34. Mechanical Properties and Biocompatibility of Various Cobalt–Chromium Alloys for Dental Prostheses
35. Mechanical Behavior of 316L Stainless Steel Fabricated by Selective Laser Melting
36. Polyetheretherketone—A Suitable Material for Fixed Dental Prostheses?10.1002/jbm.b.32932 ↗
37. Modified PEEK as an Alternative Crown Framework Material for Weak Abutment Teeth: A Case Report
38. Effect of Aging and Thermocycling on Flexural Strength of PEEK as a Provisional Restoration for Full Mouth Rehabilitation—An In Vitro Study10.4103/ijdr.ijdr_195_21 ↗
39. Wang, B., Huang, M., Dang, P., Xie, J., Zhang, X., and Yan, X. (2022). PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement. Polymers, 14.10.3390/polym14122323 ↗