journal article·2025-11-24Open access

Simulation of the Periodontal Ligament in Dental Materials Research: A CAD/CAM-Based Method for PDL Modeling

Przemysław Kosewski, Juliusz Kosewski, Agnieszka Mielczarek

Journal of Functional Biomaterials· Volume 16· Issue 12

Abstract

The periodontal ligament (PDL) is essential for the physiological mobility and load distribution of natural teeth, yet its simulation in mechanical testing remains inconsistent and insufficiently standardized. The absence of a resilient suspension system can alter force transmission, affect failure patterns, and reduce the clinical relevance of in vitro outcomes. This study aimed to develop a reproducible CAD/CAM-based model for PDL simulation that provides elastic suspension of a tooth replica under laboratory conditions. A digitally defined offset was applied around a tooth replica to create a controlled PDL space, which was filled with polyether. To ensure precise seating of the specimens, a 3D-printed positioning device was used. Functional calibration was performed using Periotest measurements to identify the offset that reproduced physiological tooth mobility. A digital offset of 0.85 mm produced a radiographically confirmed polyether layer of 0.86 ± 0.05 mm and yielded Periotest values comparable to natural teeth in the horizontal direction (mean PTV = 2.99 ± 0.92). Vertical measurements demonstrated higher damping (mean PTV = −4.02 ± 0.56), consistent with the anisotropic behavior of natural PDL. The model showed high fabrication accuracy and predictable mechanical behavior, providing a physiologically relevant method for incorporating PDL simulation into laboratory mechanical testing.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental materials and restorations · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Independent Researcher, 01650 Warsaw, Poland

Department of Conservative Dentistry, Medical University of Warsaw, 02091 Warsaw, Poland

References (69)

Show source-provided references
1. In-vitro simulation of tooth mobility for static and dynamic load tests: A pilot study10.3109/00016357.2011.563244 ↗
2. Differences in the biomechanical behaviors of natural teeth and dental implants10.1016/j.dental.2021.01.003 ↗
3. Exploring the mechanical and biological interplay in the periodontal ligament10.1038/s41368-025-00354-y ↗
4. The biomechanical role of periodontal ligament in bonded and replanted vertically fractured teeth under cyclic biting forces10.1038/ijos.2014.51 ↗
5. Wear evaluation of prosthetic materials opposing themselves10.2341/16-212-L ↗
6. Singer, L., Fouda, A., and Bourauel, C. (2023). Biomimetic approaches and materials in restorative and regenerative dentistry: Review article. BMC Oral Health, 23.10.1186/s12903-023-02808-3 ↗
7. Zafar, M.S., Amin, F., Fareed, M.A., Ghabbani, H., Riaz, S., Khurshid, Z., and Kumar, N. (2020). Biomimetic aspects of restorative dentistry Biomaterials. Biomimetics, 5.10.3390/biomimetics5030034 ↗
8. The fatigue bond strength of fixed-fixed versus cantilever resin-bonded partial fixed dental prostheses10.1016/j.prosdent.2013.07.004 ↗
9. Validation of in-vitro tests of zirconia-ceramic inlay-retained fixed partial dentures: A finite element analysis10.1016/j.dental.2019.01.017 ↗
10. Influence of resilient support of abutment teeth on fracture resistance of all-ceramic fixed partial dentures: An in vitro study
11. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures10.1016/j.dental.2005.04.024 ↗
12. Survival of severely compromised endodontically treated teeth restored with or without a fiber glass post10.1590/1678-7757-2023-0241 ↗
13. Fracture resistance of pulpless teeth restored with post-cores and crowns10.1016/j.dental.2005.03.017 ↗
14. Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth10.4047/jap.2020.12.1.1 ↗
15. Kosewski, P., De Angelis, F., Sorrentino, E., Mielczarek, A., Buonvivere, M., and D’Arcangelo, C. (2023). Effect of the abutment rigidity on the wear resistance of a lithium disilicate glass ceramic: An in vitro study. J. Funct. Biomater., 14.10.3390/jfb14080395 ↗
16. In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth10.4047/jap.2018.10.4.300 ↗
17. In vitro simulation of periodontal ligament in fatigue testing of dental crowns10.1055/s-0040-1713953 ↗
18. Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments10.1111/j.1600-0501.2008.01551.x ↗
19. In-depth morphological evaluation of tooth anatomic lengths with root canal configurations using cone beam computed tomography in North American population10.1590/1678-7757-2019-0103 ↗
20. Kucher, M., Dannemann, M., Modler, N., Bernhard, M.R., Hannig, C., and Weber, M.T. (2021). Mapping of the micro-mechanical properties of human root dentin by means of microindentation. Materials, 14.10.3390/ma14030505 ↗
21. The mechanical properties of human dentin: A critical review and re-evaluation of the dental literature10.1177/154411130301400103 ↗
22. Chun, K., Choi, H., and Lee, J. (2014). Comparison of mechanical property and role between enamel and dentin in the human teeth. J. Dent. Biomech., 5.10.1177/1758736014520809 ↗
23. Hardness and indentation modulus of human enamel and dentin10.1002/sia.7187 ↗
24. Flexural strength and elastic modulus evaluation of structures made by conventional PMMA and PMMA reinforced with graphene
25. Determination of Young’s modulus of mandibular bone using inverse analysis10.1016/j.medengphy.2010.03.009 ↗
26. Influence of root embedment material and periodontal ligament simulation on fracture resistance tests10.1590/S1806-83242005000100003 ↗
27. Stability of implants and natural teeth as determined by the Periotest over 60 months of function10.1563/1548-1336(2001)027<0198:SOIANT>2.3.CO;2 ↗
28. Simulation of cumulative damage associated with long term cyclic loading using a multi-level strain accommodating loading protocol10.1016/j.dental.2012.10.009 ↗
29. Fracture resistance and biomechanical behavior of different access cavities of maxillary central incisors restored with different composite resins10.1007/s00784-022-04581-z ↗
30. Compressive strength evaluation of thin occlusal veneers from different CAD/CAM materials, before and after acidic saliva exposure10.1007/s10266-022-00741-5 ↗
31. Inclusion of the periodontal ligament in studies on the biomechanical behavior of fiber post-retained restorations: An in vitro study and three-dimensional finite element analysis10.1177/0954411916630006 ↗
32. Influence of periodontal ligament simulation on bond strength and fracture resistance of roots restored with fiber posts10.1590/1678-775720140067 ↗
33. In vitro evaluation of different diameters of quartz fiber posts on root fracture resistance
34. Vertical root fracture resistance and crack formation of root canal-treated teeth restored with different post-luting systems10.1007/s10266-022-00709-5 ↗
35. Fracture resistance of simulated immature teeth after different intra-radicular treatments10.1590/0103-6440201300186 ↗
36. Loading standardization of postendodontic restorations in vitro: Impact of restorative stage, static loading, and dynamic loading10.2341/10-355-L ↗
37. Simulation of physiological tooth mobility in in-vitro stress examination of dental restorations in the masticator
38. Micro-CT evaluation of a novel periodontal ligament simulation technique for dental experimental models
39. Fatigue resistance of all-ceramic fixed partial dentures—Fatigue tests and finite element analysis10.1016/j.dental.2017.12.005 ↗
40. Dynamic fatigue and fracture resistance of non-retentive all-ceramic full-coverage molar restorations. Influence of ceramic material and preparation design10.1016/j.dental.2010.01.011 ↗
41. Fracture resistance and wear behavior of ultra-thin occlusal veneers made from translucent zirconia ceramics bonded to different tooth substrates10.1111/jerd.13409 ↗
42. Influence of bonding surface and bonding methods on the fracture resistance and survival rate of full-coverage occlusal veneers made from lithium disilicate ceramic after cyclic loading10.1016/j.dental.2019.07.001 ↗
43. Load-bearing capacity of all-ceramic posterior inlay-retained fixed dental prostheses10.1111/j.1600-0722.2009.00626.x ↗
44. Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports10.1007/s00784-011-0569-0 ↗
45. Influence of restoration thickness and dental bonding surface on the fracture resistance of full-coverage occlusal veneers made from lithium disilicate ceramic10.1016/j.dental.2015.04.017 ↗
46. Effect of luting agent on the load-bearing capacity of milled hybrid ceramic single-tooth restoration10.51847/l0X0mVhoeA ↗
47. Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology10.1007/s00784-019-03000-0 ↗
48. A novel digital workflow for fabricating artificial periodontal ligament using three-dimensional printing flexible resin: A dental technique10.1016/j.sdentj.2023.10.014 ↗
49. Marginal accuracy of combined tooth-implant-supported fixed dental prostheses after in vitro stress simulation10.1111/j.1600-0501.2008.01593.x ↗
50. Reattachment of anterior fractured teeth: Effect of materials and techniques on impact strength10.1111/j.1600-9657.2010.00906.x ↗
51. Fracture strength of flared bovine roots restored with different intraradicular posts10.1590/S1678-77572009000600007 ↗
52. A comparison of spreader penetration depth and load required during lateral condensation in teeth prepared using various root canal preparation techniques10.1111/j.1365-2591.2005.00969.x ↗
53. Effects of adjacent tooth type and occlusal fatigue on proximal contact force of posterior bulk fill and incremental resin composite restoration10.2341/20-019-L ↗
54. The effect of spreader size on fracture resistance of maxillary incisor roots10.1111/j.1365-2591.2007.01314.x ↗
55. Influence of cementation on in vitro performance, marginal adaptation and fracture resistance of CAD/CAM-fabricated ZLS molar crowns10.1016/j.dental.2015.08.154 ↗
56. Effect of bone loss simulation and periodontal splinting on bone strain: Periodontal splints and bone strain10.1016/j.archoralbio.2011.04.002 ↗
57. Similar influence of stabilized alkaline and neutral sodium hypochlorite solutions on the fracture resistance of root canal-treated bovine teeth10.1016/j.joen.2014.02.028 ↗
58. Resistance of teeth with simulated incomplete rhizogenesis with intraradicular post or root canal filling10.5005/jp-journals-10024-1554 ↗
59. In vitro comparison of the load-bearing capacity of ceramic and metal-ceramic resin-bonded fixed dental prostheses in the posterior region10.1016/j.prosdent.2017.03.006 ↗
60. In-vitro performance and fracture strength of thin monolithic zirconia crowns10.4047/jap.2018.10.2.79 ↗
61. In vitro splint rigidity evaluation—Comparison of a dynamic and a static measuring method10.1111/j.1600-9657.2011.01034.x ↗
62. Influence of wire extension and type on splint rigidity—Evaluation by a dynamic and a static measuring method10.1111/j.1600-9657.2011.01033.x ↗
63. Mechanical properties of elastomeric impression materials: An in vitro comparison10.1155/2015/428286 ↗
64. Viscoelastic response of the periodontal ligament: An experimental-numerical analysis10.1080/03008200490885742 ↗
65. An investigation into the importance of the periodontal ligament and alveolar bone as supporting structures in finite element studies10.1046/j.1365-2842.2001.00686.x ↗
66. Deformation analysis of the periodontium considering the viscoelasticity of the periodontal ligament10.1016/j.dental.2009.03.014 ↗
67. An evaluation of the Periotest method as a tool for monitoring tooth mobility in dental traumatology10.1111/j.1600-9657.2009.00860.x ↗
68. PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation10.7326/M18-0850 ↗
69. Fracture behavior of inlay and onlay fixed partial dentures—An in-vitro experimental and XFEM modeling study10.1016/j.jmbbm.2016.01.035 ↗