Handheld Nonthermal Plasma Augmentation of Glass–Ceramic Spray Deposition on Zirconia Surface Characterization and MG-63/HGF-1 Cell Behavior: An In Vitro Study
Source abstract
Abstract
Zirconia is widely used for customized implant abutments owing to its esthetics, strength, and biocompatibility; however, the optimal surface modification for soft-tissue sealing and bone metabolic remains uncertain. This study evaluated how glass–ceramic spray deposition (GCSD), with or without handheld nonthermal plasma (HNP), alters zirconia surface physiochemistry and cellular responses. Field-emission scanning electron microscopy/energy-dispersive X-ray spectroscopy, surface roughness (Ra), wettability, and surface free energy (SFE) were measured. Human osteoblast-like cells (MG-63) and human gingival fibroblasts (HGF-1) were used to assess attachment and spreading, metabolic activity, cytotoxicity, and inflammatory response (tumor necrosis factor-α, TNF-α) (α = 0.05). GCSD produced an interlaced rod- and needle-like glass–ceramic layer, significantly increasing Ra and hydrophilicity. HNP further reduced surface contaminants, increased SFE, and enhanced wettability. The combination of GCSD and HNP yielded the greatest attachment and spreading for both cell types, without increases in cytotoxicity or TNF-α. GCSD with HNP creates a hydrophilic, micro-textured, chemically activated zirconia surface that maintains biocompatibility while promoting early attachment and bone metabolic activity, supporting its application for zirconia implant abutments.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Advanced ceramic materials synthesis · Periodontal Regeneration and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
Department of Medical Systems Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City 734-8553, Japan
Department of Oral Medicine, Taipei Medical University-Shuang Ho Hospital, New Taipei City 23561, Taiwan
Funding
National Science and Technology Council of Taiwan · Taipei Medical University · Taipei Medical University Shuang Ho Hospital
References (44)
Show source-provided references
1. Current status of zirconia restoration10.1016/j.jpor.2013.09.001 ↗
2. Wear behavior of different generations of zirconia: Present literature10.1155/2022/9341616 ↗
3. The tetragonal-monoclinic transformation in zirconia: Lessons learned and future trends10.1111/j.1551-2916.2009.03278.x ↗
4. Characterization of a Diamond Ground Y-TZP and Reversion of the Tetragonal to Monoclinic Transformation10.2341/16-196-L ↗
5. Zirconia in fixed prosthesis. A literature review
6. High fracture toughness of 3Y-TZP ceramic over a wide sintering range10.1016/j.matchemphys.2020.122693 ↗
7. Visualization of transformation toughening of zirconia ceramics during dynamic fracture10.1063/5.0044607 ↗
8. Grain size, crystalline phase and fracture toughness of the monolithic zirconia10.4047/jap.2022.14.5.285 ↗
9. Color Aspect of Monolithic Zirconia Restorations: A Review of the Literature10.1111/jopr.12906 ↗
10. Optical properties of translucent zirconia: A review of the literature10.2478/ebtj-2019-0005 ↗
11. Corrosion and low temperature degradation of 3Y-TZP dental ceramics under acidic conditions10.1016/j.jeurceramsoc.2020.06.019 ↗
12. Lin, H., Yin, C., and Mo, A. (2021). Zirconia based dental biomaterials: Structure, mechanical properties, biocompatibility, surface modification, and applications as implant. Front. Dent. Med., 2.10.3389/fdmed.2021.689198 ↗
13. Jung, S., Moser, M.M., Kleinheinz, J., and Happe, A. (2021). Biocompatibility of Lithium Disilicate and Zirconium Oxide Ceramics with Different Surface Topographies for Dental Implant Abutments. Int. J. Mol. Sci., 22.10.3390/ijms22147700 ↗
14. Influence of cold atmospheric plasma on dental implant materials—An in vitro analysis10.1007/s00784-021-04277-w ↗
15. Staehlke, S., Brief, J., Senz, V., Eickner, T., and Nebe, J.B. (2023). Optimized Gingiva Cell Behavior on Dental Zirconia as a Result of Atmospheric Argon Plasma Activation. Materials, 16.10.3390/ma16124203 ↗
16. Guo, L., Zou, Z., Smeets, R., Kluwe, L., Hartjen, P., Gosau, M., and Henningsen, A. (2022). Attachment and Osteogenic Potential of Dental Pulp Stem Cells on Non-Thermal Plasma and UV Light Treated Titanium, Zirconia and Modified PEEK Surfaces. Materials, 15.10.3390/ma15062225 ↗
17. Halim, F.C., Pesce, P., De Angelis, N., Benedicenti, S., and Menini, M. (2022). Comparison of the clinical outcomes of titanium and zirconia implant abutments: A systematic review of systematic reviews. J. Clin. Med., 11.10.3390/jcm11175052 ↗
18. Effect of different customized abutment types on stress distribution in implant-supported single crown: A 3D finite element analysis10.1111/jopr.13530 ↗
19. Effects of glass-ceramic spray deposition manipulation on the surface characteristics of zirconia dental restorations10.1016/j.ceramint.2022.06.252 ↗
20. Digital evaluation of the effect of nanosilica-lithium spray coating on the internal and marginal fit of high translucent zirconia crowns10.1016/j.jdent.2023.104503 ↗
21. Shen, D., Wang, H., Shi, Y., Su, Z., Hannig, M., and Fu, B. (2023). The effect of surface treatments on zirconia bond strength and durability. J. Funct. Biomater., 14.10.3390/jfb14020089 ↗
22. Kang, C.-M., Lin, D.-J., Feng, S.-W., Hung, C.-Y., Iwaguro, S., and Peng, T.-Y. (2022). Innovation glass-ceramic spray deposition technology improving the adhesive performance for zirconium-based dental restorations. Int. J. Mol. Sci., 23.10.3390/ijms232112783 ↗
23. Effects of hydrofluoric acid concentration and etching time on the bond strength to ceramic-coated zirconia
24. In vitro biocompatibility of new bioactive lithia-silica glass-ceramics10.1016/j.msec.2018.09.006 ↗
25. Hsu, W.-C., Cha, T.-Y., Yao, Y.-C., Kang, C.-M., Wu, S.-H., Mine, Y., Tseng, C.-F., Lee, I.-T., Lin, D.-J., and Peng, T.-Y. (2025). Promoting surface energy and osteoblast viability on zirconia implant abutments through glass–ceramic spray deposition technology. J. Funct. Biomater., 16.10.3390/jfb16080288 ↗
26. A novel polymer infiltrated ceramic dental material10.1016/j.dental.2011.02.002 ↗
27. Fracture Resistance of Single-Unit Implant-Supported Crowns: Effects of Prosthetic Design and Restorative Material10.1111/jopr.13415 ↗
28. Effect of different occlusal materials on peri-implant stress distribution with different osseointegration condition: A finite element analysis10.4103/jips.jips_424_23 ↗
29. Effects of handheld nonthermal plasma on the biological responses, mineralization, and inflammatory reactions of polyaryletherketone implant materials10.1016/j.jds.2024.06.014 ↗
30. Lee, S.K., Ji, M.K., Jo, Y.J., Park, C., Cho, H., and Lim, H.P. (2022). Effect of Non-Thermal Plasma Treatment of Contaminated Zirconia Surface on Porphyromonas gingivalis Adhesion and Osteoblast Viability. Materials, 15.10.3390/ma15155348 ↗
31. Influence of handheld nonthermal plasma on shear bond strength of polyaryletherketone to resin-matrix cement10.1016/j.jds.2024.05.029 ↗
32. Lai, S.-Y., Lin, S.-I., Chang, C.-W., Shen, Y.-R., Mine, Y., Lin, Z.-C., Fang, M.-L., Sung, C.-C., Tseng, C.-F., and Peng, T.-Y. (2025). Comparative evaluation of dental clinical surface treatments for polyetheretherketone with airborne-particle abrasion, hydrofluoric acid etching, and handheld nonthermal plasma activation on long-term bond performance. Polymers, 17.10.3390/polym17111448 ↗
33. (2018). Granulated Cork and Cork Powder—Classification, Properties and Packing (Standard No. ISO 1997: 2018).
34. Reversible surface wettability by silanization10.1002/admi.201902134 ↗
35. Lai, S.-Y., Wei, C., and Peng, T.-Y. (J. Prosthet. Dent., 2025). Enhancing bonding and durability of polyaryletherketone (PAEK) restorations with nonthermal plasma activation and monomer-based priming, J. Prosthet. Dent., in press.10.1016/j.prosdent.2025.08.029 ↗
36. Aging effect of atmospheric air on lithium disilicate ceramic after nonthermal plasma treatment10.1016/j.prosdent.2015.11.008 ↗
37. Zirconia surface modifications for implant dentistry10.1016/j.msec.2019.01.062 ↗
38. Qu, Y., and Liu, L. (2021). Zirconia materials for dental implants: A literature review. Front. Dent. Med., 2.10.3389/fdmed.2021.687983 ↗
39. Jia, F., Wang, S., Xu, S., Wu, W., Zhou, L., and Zeng, J. (2022). The role of titanium surface micromorphology in MG-63 cell motility during osteogenesis. Sci. Rep., 12.10.1038/s41598-022-13854-2 ↗
40. Guided gingival fibroblast attachment to titanium surfaces: An in vitro study10.1111/jcpe.12025 ↗
41. Influence of clinical zirconia surface treatments on microscopic characteristics and adhesion-proliferation behavior of human gingival fibroblasts10.1016/j.jormas.2023.101564 ↗
42. Wang, C., Wang, X., Lu, R., Gao, S., Ling, Y., and Chen, S. (2021). Responses of human gingival fibroblasts to superhydrophilic hydrogenated titanium dioxide nanotubes. Colloids Surf. B Biointerfaces, 198.10.1016/j.colsurfb.2020.111489 ↗
43. Staehlke, S., Oster, P., Seemann, S., Kruse, F., Brief, J., and Nebe, B. (2022). Laser Structured Dental Zirconium for Soft Tissue Cell Occupation—Importance of Wettability Modulation. Materials, 15.10.3390/ma15030732 ↗
44. Effects of Surface Treatment and Dental Preparation on the Fracture and Debonding of High-Translucency Zirconia Occlusal Veneers10.1111/jerd.13509 ↗