Biological Response of Osteoblasts to Zirconia Manufactured via FFF, DLP, and Milling
Source abstract
Abstract
(1) Background: Zirconia (ZrO2) is increasingly used in dental implantology due to its biocompatibility and favorable mechanical and biological properties. While subtractive and stereolithographic additive manufacturing techniques are well established, the application of Fused Filament Fabrication (FFF) for zirconia-based dental implants remains largely unexplored. (2) Methods: Cylindrical ZrO2 specimens were fabricated using three different manufacturing techniques: milling (MIL), Digital Light Processing (DLP), and FFF. Surface topography was analyzed via white-light interferometry. Human fetal osteoblasts (hFOBs 1.19) were cultured on the specimens to evaluate cell adhesion after 4 and 24 h, proliferation for 4 days, cell surface coverage after 4 and 24 h, and osteogenic gene expression (RUNX2, ALPL, and BGLAP) after 24 h, 48 h, 7 days, and 14 days. (3) Results: The FFF samples exhibited significantly higher surface roughness than the MIL and DLP specimens. After 24 h, enhanced cell adhesion and the highest proliferation rates were observed on FFF surfaces. At 14 days, gene expression analysis revealed elevated expression of BGLAP on FFF surfaces, suggesting advanced osteogenic differentiation compared to MIL and DLP. (4) Conclusions: The inherent surface roughness of FFF-printed zirconia appears to promote osteogenic activity without additional surface treatment. These findings suggest that FFF may constitute a viable manufacturing method for the fabrication of customized zirconia components in dental implantology, warranting further investigations, particularly regarding their mechanical performance.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · 3D Printing in Biomedical Research · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
Department of Prosthodontics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
Institute for Applied Materials, Karlsruhe Institute of Technology, Herrmann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
Funding
Dietmar Hopp Foundation, Germany · HEiKA (Heidelberg Karlsruhe Stratetic Partnership) Program
References (60)
Show source-provided references
1. Shelar, P., Abdolvand, H., and Butler, S. (2021). On the behaviour of zirconia-based dental materials: A review. J. Mech. Behav. Biomed. Mater., 124.10.1016/j.jmbbm.2021.104861 ↗
2. In Vitro Biofilm Formation on Titanium and Zirconia Implant Surfaces10.1902/jop.2016.160245 ↗
3. Titanium and zirconium release from titanium- and zirconia implants in mini pig maxillae and their toxicity in vitro10.1016/j.dental.2020.01.013 ↗
4. Ligature-Induced Peri-implant Bone Loss Around Loaded Zirconia and Titanium Implants10.11607/jomi.7015 ↗
5. Performance and outcome of zirconia dental implants in clinical studies: A meta-analysis10.1111/clr.13352 ↗
6. Clinical Outcomes of Zirconia Dental Implants: A Systematic Review10.1177/0022034516664043 ↗
7. Kohal, R.J., Spies, B.C., Vach, K., Balmer, M., and Pieralli, S. (2020). A Prospective Clinical Cohort Investigation on Zirconia Implants: 5-Year Results. J. Clin. Med., 9.10.3390/jcm9082585 ↗
8. 3D printing of ceramics: A review10.1016/j.jeurceramsoc.2018.11.013 ↗
9. Understanding dental CAD/CAM for restorations—Dental milling machines from a mechanical engineering viewpoint. Part B: Labside milling machines
10. A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia10.3390/ma8030932 ↗
11. Digital dentistry: An overview of recent developments for CAD/CAM generated restorations10.1038/sj.bdj.2008.350 ↗
12. da Cruz, M.B., Marques, J.F., Silva, N., Madeira, S., Carvalho, O., Silva, F.S., Carames, J., and Mata, A. (2022). Human Gingival Fibroblast and Osteoblast Behavior on Groove-Milled Zirconia Implant Surfaces. Materials, 15.10.3390/ma15072481 ↗
13. The Flexural Strength and Flexural Modulus of Stereolithography Additively Manufactured Zirconia with Different Porosities10.1111/jopr.13430 ↗
14. Fused Filament Fabrication (FFF) of Metal-Ceramic Components
15. Eickenscheidt, M., Langenmair, M., Dbouk, A., Nötzel, D., Hanemann, T., and Stieglitz, T. (2021). 3D-Printed Hermetic Alumina Housings. Materials, 14.10.3390/ma14010200 ↗
16. Nötzel, D., Eickhoff, R., and Hanemann, T. (2018). Fused Filament Fabrication of Small Ceramic Components. Materials, 11.10.3390/ma11081463 ↗
17. Additive manufacturing of dental ceramics in prosthodontics: The status quo and the future10.2186/jpr.JPR_D_23_00119 ↗
18. Current applications of 3D printing in dental implantology: A scoping review mapping the evidence10.1111/clr.14198 ↗
19. Alqutaibi, A.Y., Alghauli, M.A., Aljohani, M.H.A., and Zafar, M.S. (2024). Advanced additive manufacturing in implant dentistry: 3D printing technologies, printable materials, current applications and future requirements. Bioprinting, 42.10.1016/j.bprint.2024.e00356 ↗
20. The Roles of Micro- and Nanoscale Materials in Cell-Engineering Systems10.1002/adma.202410908 ↗
21. Rougerie, P., Pieuchot, L., dos Santos, R.S., Marteau, J., Bigerelle, M., Chauvy, P.F., Farina, M., and Anselme, K. (2020). Topographical curvature is sufficient to control epithelium elongation. Sci. Rep., 10.10.1038/s41598-020-70907-0 ↗
22. Local force and geometry sensing regulate cell functions10.1038/nrm1890 ↗
23. Strength and reliability of zirconia fabricated by additive manufacturing technology10.1016/j.dental.2022.07.004 ↗
24. Nötzel, D., and Hanemann, T. (2020). New Feedstock System for Fused Filament Fabrication of Sintered Alumina Parts. Materials, 13.10.3390/ma13194461 ↗
25. Nötzel, D. (2023). Herstellung Keramischer Bauteile Mittels Fused Filament Fabrication (FFF). [Ph.D. Thesis, University of Freiburg].
26. Analysis of relative gene expression data using real-time quantitative PCR and the 2−ΔΔCT Method10.1006/meth.2001.1262 ↗
27. Surface Topography of Additive Manufacturing Parts Using a Finite Difference Approach10.1115/1.4028585 ↗
28. Quantitative analysis of surface profile in fused deposition modelling
29. Representation of surface roughness in fused deposition modeling10.1016/j.jmatprotec.2009.05.016 ↗
30. Surface roughness prediction in fused deposition modelling by neural networks10.1007/s00170-012-4687-x ↗
31. Characterization of zirconia specimens fabricated by ceramic on-demand extrusion10.1016/j.ceramint.2018.04.008 ↗
32. Development and characterization of a conditionally immortalized human fetal osteoblastic cell line10.1002/jbmr.5650100203 ↗
33. Osteoblast behaviour on zirconia fabricated by additive and subtractive technology10.1016/j.ceramint.2022.11.030 ↗
34. Crystal structure of zirconia affects osteoblast behavior10.1016/j.dental.2020.04.017 ↗
35. Behavior of SaOS-2 cells cultured on different titanium surfaces10.1177/154405910308200907 ↗
36. Response of human bone marrow stromal cells, MG-63, and SaOS-2 to titanium-based dental implant surfaces with different topography and surface energy10.1111/j.1600-0501.2011.02328.x ↗
37. Requirement for both micron- and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topography10.1016/j.biomaterials.2007.02.024 ↗
38. Han, X., Sharma, N., Xu, Z., Scheideler, L., Geis-Gerstorfer, J., Rupp, F., Thieringer, F.M., and Spintzyk, S. (2019). An In Vitro Study of Osteoblast Response on Fused-Filament Fabrication 3D Printed PEEK for Dental and Cranio-Maxillofacial Implants. J. Clin. Med., 8.10.3390/jcm8060771 ↗
39. Observation of ground surface roughness values obtained by stylus profilometer and white light interferometer for common metal materials10.1002/sia.7068 ↗
40. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗
41. Cell shape, cytoskeletal tension, and RhoA regulate stem cell lineage commitment10.1016/S1534-5807(04)00075-9 ↗
42. Osteoblast response to zirconia surfaces with different topographies10.1016/j.msec.2015.07.052 ↗
43. Parametric appraisal of fused deposition modelling process using the grey Taguchi method10.1243/09544054JEM1565 ↗
44. Improving dimensional accuracy of Fused Deposition Modelling processed part using grey Taguchi method10.1016/j.matdes.2009.04.030 ↗
45. A Study on Dimensional Accuracy of Fused Deposition Modeling (FDM) Processed Parts using Fuzzy Logic
46. Effects of nozzle-bed distance on the surface quality and mechanical properties of fused filament fabrication parts10.1088/1757-899X/479/1/012094 ↗
47. An experimental investigation on surface quality and dimensional accuracy of FDM
48. Analysis on fused deposition modelling performance10.1631/jzus.A1001365 ↗
49. A Study of Build Edge Profile for Prediction of Surface Roughness in Fused Deposition Modeling10.1115/1.4032193 ↗
50. Shilov, S.Y., Rozhkova, Y.A., Markova, L.N., Tashkinov, M.A., Vindokurov, I.V., and Silberschmidt, V.V. (2022). Biocompatibility of 3D-Printed PLA, PEEK and PETG: Adhesion of Bone Marrow and Peritoneal Lavage Cells. Polymers, 14.10.3390/polym14193958 ↗
51. A review on voids of 3D printed parts by fused filament fabrication10.1016/j.jmrt.2021.10.108 ↗
52. 3D printed zirconia dental implants with integrated directional surface pores combine mechanical strength with favorable osteoblast response10.1016/j.actbio.2022.07.030 ↗
53. Is a Zirconia Dental Implant Safe When It Is Available on the Market?10.3390/ceramics2040044 ↗
54. Influence of surface modifications on the fracture resistance of aged zirconia implants: A systematic review of in vitro experimental studies10.1016/j.ajoms.2023.06.001 ↗
55. Stoilov, M., Stoilov, L., Enkling, N., Stark, H., Winter, J., Marder, M., and Kraus, D. (2022). Effects of Different Titanium Surface Treatments on Adhesion, Proliferation and Differentiation of Bone Cells: An In Vitro Study. J. Funct. Biomater., 13.10.3390/jfb13030143 ↗
56. Nemcakova, I., Jirka, I., Doubkova, M., and Bacakova, L. (2020). Heat treatment dependent cytotoxicity of silicalite-1 films deposited on Ti-6Al-4V alloy evaluated by bone-derived cells. Sci. Rep., 10.10.1038/s41598-020-66228-x ↗
57. The gene-expression and phenotypic response of hFOB 1.19 osteoblasts to surface-modified titanium and zirconia10.1016/j.biomaterials.2008.10.054 ↗
58. Osteoblast and bone tissue response to surface modified zirconia and titanium implant materials10.1016/j.dental.2013.04.003 ↗
59. Soft-tissue integration of implants10.1111/j.1600-0501.2006.001366.x ↗
60. Kligman, S., Ren, Z., Chung, C.H., Perillo, M.A., Chang, Y.C., Koo, H., Zheng, Z., and Li, C. (2021). The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation. J. Clin. Med., 10.10.3390/jcm10081641 ↗