Show source-provided references
1. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
10.3109/17453678108991776 ↗3. Primary stability, insertion torque and bone density of cylindrical implant ad modum Brånemark: Is there a relationship? An in vitro study
10.1111/j.1600-0501.2010.02036.x ↗4. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: A clinical study including bone density, insertion torque, and resonance frequency analysis data
10.1111/j.1708-8208.2008.00084.x ↗6. Correlation between placement torque and survival of single-tooth implants
7. Correlation between initial BIC and the Insertion Torque/Depth Integral Recorded with an Instantaneous Torque- Measuring Implant Motor: An in vivo Study
8. A novel osseous densification approach in implant osteotomy preparation to increase biomechanical primary stability, bone mineral density, and bone-to-implant contact
10.11607/jomi.4817 ↗9. Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. An experimental study in sheep
10.1016/j.jmbbm.2016.06.007 ↗10. Effects on ridge dimensions, bone density, and implant primary stability with osseodensification approach in implant osteotomy preparation
10.11607/jomi.8540 ↗11. Insertion and removal torque of dental implants placed using different drilling protocols: An experimental study on artificial bone substitutes
10.1111/jopr.13607 ↗12. Radiographical and histological characteristics of submerged and non-submerged titanium implants. An experimental study in the Labrador dog
10.1034/j.1600-0501.1996.070103.x ↗16. Investigation of the effect of movement and irrigation systems on temperature in the conventional drilling of cortical bone
10.1016/j.bjoms.2012.10.023 ↗18. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
21. The effect of irrigation on osteotomy depth and bur diameter
22. The effect of load on heat production, thermal effects, and expenditure of time during implant site preparation—An experimental ex vivo comparison between piezosurgery and conventional drilling
10.1111/clr.12077 ↗23. Microcirculation in grafted bone
24. Influence of multiple use of Timedur-titanium cannon drills: Thermal response and scanning electron microscopic findings
25. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model
10.1111/clr.12032 ↗26. Soldatos, N., Pham, H., Fakhouri, W.D., Ngo, B., Lampropoulos, P., Tran, T., and Weltman, R. (2022). Temperature changes during implant osteotomy preparations in human cadaver tibiae comparing MIS® straight drills with Densah® burs. Genes, 13.
10.3390/genes13101716 ↗27. Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: An ex vivo study on porcine ribs
10.1007/s10266-022-00730-8 ↗28. Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
10.1016/S0278-2391(99)90437-8 ↗29. Soldatos, N., Nelson-Rabe, L., Palanker, N., Angelov, N., Romanos, G., and Weltman, R. (2022). Temperature changes during implant osteotomy preparations in fresh human cadaver tibiae, comparing straight with tapered drills. Materials, 15.
10.3390/ma15072369 ↗30. R Core Team (2021). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing. Available online: https://www.R-project.org/.
33. An in vitro study of temperature changes in type 4 bone during implant placement: Bone condensing versus bone drilling. Oral Surg
10.1016/j.tripleo.2010.08.010 ↗35. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants
36. Effect of temperature on the dental implant osseointegration development in low-density bone: An in vivo histological evaluation
10.1097/ID.0000000000000204 ↗38. Temperature Changes during Implant Osteotomies Utilizing three different implant systems: A pilot study
40. Evaluation of bone heating, drill deformation, and drill roughness after implant osteotomy: Guided surgery and classic drilling procedure
10.11607/jomi.2919 ↗41. Intraosseous heat generation during osteotomy performed freehand and through template with an integrated metal guide sleeve: An in vitro study
10.1097/ID.0000000000000763 ↗43. Temperature changes in bovine mandibular bone during implant site preparation: An assessment using infra-red thermography
10.1016/0300-5712(95)00072-0 ↗45. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: Twisted stainless steel and ceramic drills
10.1111/j.1600-0501.2011.02248.x ↗47. Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Cylindrical versus Conical Drills
10.1111/j.1708-8208.2009.00209.x ↗48. Yu, K., Iwata, S., Ohnishi, K., Usuda, S., Nakagawa, T., and Kawana, H. (2014, January 14–16). Modeling and experimentation of drilling vibration for implant cutting force presenting system. Proceedings of the 2014 IEEE 13th International Workshop on Advanced Motion Control (AMC), Yokohama, Japan.
10.1109/AMC.2014.6823368 ↗