Effect of Cleaning Protocols on Surface Roughness of Current Polymeric Denture Materials
Source abstract
Abstract
Surface roughness influences biofilm adhesion on denture base materials, impacting oral health. Despite advances in polymeric denture materials, the effects of common cleaning protocols on their surface texture remain inadequately characterized. This study investigated the influence of toothbrush abrasion on the surface texture of dimethyl methacrylate-based (DMA, printed: V-Print dentbase), polymethyl methacrylate (PMMA, milled: VITA Vionic Base, pressed: IvoBase Hybrid), polyamide (PA, pressed: Bre.flex), and polyether ether ketone (PEEK, milled: Juvora Disc). The specimens were fabricated as polished discs. The Vickers and Martens hardness, indentation modulus, elastic and plastic part of indentation work, and indentation creep were determined. Toothbrushing simulation and surface texture analysis were conducted in three steps: 1800, 1800, and 3600 cycles using water, dish detergent, or toothpaste slurry. The surface texture parameters Sa, Sal, Sdr, Sku, and Ssk were determined using confocal laser scanning microscopy and suitable filtering (S-F and S-L surface). Sa, Sal, and Sdr showed significant changes depending on the choice of medium and the material used. The duration had a small effect (three-way ANOVA; all p < 0.001). DMA showed minor surface changes. Milled and pressed PMMA exhibited similar surface deformities due to wide valleys that were not considered critical for biofilm adhesion. PA showed the lowest and PEEK the highest Vickers and Martens hardness. However, both PA and PEEK exhibited surface changes that could promote biofilm development. These findings suggest that denture cleaning recommendations should remain material-specific. Regular surface inspections and repolishing are necessary to reduce the risk of biofilm formation on PA or PEEK-containing dentures.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany
Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
Department of Prosthodontics and Materials Science, Rostock University, Strempelstraße 13, 18057 Rostock, Germany
References (61)
Show source-provided references
1. Tooth loss and oral health-related quality of life: A systematic review and meta-analysis10.1186/1477-7525-8-126 ↗
2. Tooth loss and denture status: Results of the 6th German Oral Health Study (DMS • 6)
3. Zafar, M.S. (2020). Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update. Polymers, 12.10.3390/polym12102299 ↗
4. Comparative analysis of leaching residual monomer and biological effects of four types of conventional and CAD/CAM dental polymers: An in vitro study10.1007/s00784-021-04271-2 ↗
5. A comparison of mechanic properties regarding complete removable dentures, which were made from polymethylmethacrilate (PMMA) during conventional and CAD/CAM processes: Systemic literature review
6. Schmutzler, A., Stingu, C.S., Günther, E., Lang, R., Fuchs, F., Koenig, A., Rauch, A., and Hahnel, S. (2023). Attachment of Respiratory Pathogens and Candida to Denture Base Materials-A Pilot Study. J. Clin. Med., 12.10.3390/jcm12196127 ↗
7. Update on Acrylic Resins Used in Dentistry10.2174/1389557521666210226151214 ↗
8. Effects of cleansing methods on 3-D surface roughness, gloss and color of a polyamide denture base material10.3109/00016357.2014.967720 ↗
9. Polyetheretherketone Material in Dentistry
10. Performance of polyetheretherketone (PEEK) versus cobalt chromium to fabricate removable partial denture frameworks: A systematic review10.1016/j.prosdent.2025.05.034 ↗
11. Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types10.4012/dmj.2013-345 ↗
12. Schönhoff, L.M., Mayinger, F., Eichberger, M., Reznikova, E., and Stawarczyk, B. (2021). 3D printing of dental restorations: Mechanical properties of thermoplastic polymer materials. J. Mech. Behav. Biomed. Mater., 119.10.1016/j.jmbbm.2021.104544 ↗
13. Critical stress analysis for the basis of a denture prosthesis10.1088/1757-899X/927/1/012008 ↗
14. A systematic review of digital removable partial dentures. Part II: CAD/CAM framework, artificial teeth, and denture base10.2186/jpr.JPR_D_20_00117 ↗
15. Luo, C., Liu, Y., Peng, B., Chen, M., Liu, Z., Li, Z., Kuang, H., Gong, B., Li, Z., and Sun, H. (2023). PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties. Polymers, 15.10.3390/polym15020386 ↗
16. Flexural strength of polyether ether ketone high-performance polyether in comparison with base metal alloy and Zirconia ceramic10.17126/joralres.2020.010 ↗
17. Assessing biocompatibility & mechanical testing of 3D-printed PEEK versus milled PEEK10.1016/j.heliyon.2022.e12314 ↗
18. Geiger, V., Mayinger, F., Hoffmann, M., Reymus, M., and Stawarczyk, B. (2024). Fracture toughness, work of fracture, flexural strength and elastic modulus of 3D-printed denture base resins in two measurement environments after artificial aging. J. Mech. Behav. Biomed. Mater., 150.10.1016/j.jmbbm.2023.106234 ↗
19. Kreitczick, J., Schmohl, L., Hahnel, S., Vejjasilpa, K., Schulz-Siegmund, M., and Koenig, A. (2024). Aging processes in dental thermoplastics—Thermoanalytical investigations and effects on Vickers as well as Martens hardness. J. Mech. Behav. Biomed. Mater., 154.10.1016/j.jmbbm.2024.106501 ↗
20. Fouda, S., Ji, W., Gad, M.M., AlGhamdi, M.A., and Rohr, N. (2025). Flexural Strength and Surface Properties of 3D-Printed Denture Base Resins-Effect of Build Angle, Layer Thickness and Aging. Materials, 18.10.3390/ma18040913 ↗
21. Hardness, flexural strength, and flexural modulus comparisons of three differently cured denture base systems10.1111/j.1532-849X.2008.00357.x ↗
22. Comparative Evaluation of Two Body Wear of PEEK vs Milled PMMA vs Indirect Composite After Chewing Simulation- An In Vitro Study
23. Effects of thermal cycling on surface roughness, hardness and flexural strength of polymethylmethacrylate and polyamide denture base resins
24. Effect of temperature and strain rate on the tensile deformation of polyamide 610.1016/j.polymer.2007.03.013 ↗
25. The effect of artificial aging on Martens hardness and indentation modulus of different dental CAD/CAM restorative materials10.1016/j.jmbbm.2018.06.028 ↗
26. Rosentritt, M., Hahnel, S., Schneider-Feyrer, S., Strasser, T., and Schmid, A. (2022). Martens Hardness of CAD/CAM Resin-Based Composites. Appl. Sci., 12.10.3390/app12157698 ↗
27. Effects of storage and toothbrush simulation on Martens hardness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials10.1007/s00784-023-05378-4 ↗
28. Ill Effects and Complications Associated to Removable Dentures With Improper Use and Poor Oral Hygiene: A Systematic Review
29. Dental health professional recommendation and consumer habits in denture cleansing10.1016/j.prosdent.2015.08.007 ↗
30. Cleaning of Removable Dental Prostheses—A Systematic Review10.1016/j.jebdp.2021.101644 ↗
31. Effects of short-term immersion and brushing with different denture cleansers on the roughness, hardness, and color of two types of acrylic resin
32. Ozyilmaz, O.Y., and Akin, C. (2019). Effect of cleansers on denture base resins’ structural properties. J. Appl. Biomater. Funct. Mater., 17.10.1177/2280800019827797 ↗
33. Effect of simulated brushing with dentifrices on surface roughness and the mass loss of acrylic resin: A systematic review and meta-analysis of in vitro studies10.1016/j.prosdent.2023.06.027 ↗
34. The effect of cleaning substances on the surface of denture base material10.12659/MSM.889568 ↗
35. (2021). Geometrical Product Specifications (GPS)—Surface Texture: Areal—Part 2: Terms, Definitions and Surface Texture Parameters (Standard No. ISO 25178-2:2021).
36. Acid resistance of self-adhesive resin luting cements—Changes in surface texture parameters and microhardness10.1016/j.dental.2022.06.013 ↗
37. (2022). Geometrische Produktspezifikation_(GPS)_- Oberflächenbeschaffenheit: Profile_- Teil_1: Angabe der Oberflächenbeschaffenheit (ISO_21920-1:2021); Deutsche Fassung EN_ISO_21920-1:2022 (Standard No. DIN EN ISO 21920-1:2022-12).
38. (2015). Metallic Materials—Instrumented Indentation Test for Hardness and Materials Parameters—Part 1: Test Method (Standard No. ISO 14577-1:2015).
39. (2024). Metallische Werkstoffe_- Härteprüfung nach Vickers_- Teil_1: Prüfverfahren (ISO_6507-1:2023); Deutsche Fassung EN_ISO_6507-1:2023 (Standard No. DIN EN ISO 6507-1:2024-01).
40. Application of macro photography in dental materials science10.1016/j.jdent.2020.103495 ↗
41. Cohen, J. (1988). Statistical Power Analysis for the Behavioral Sciences, Lawrence Erlbaum Associates Publishers. [2nd ed.].
42. G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences10.3758/BF03193146 ↗
43. Effects of polymer hardness on the abrasive wear resistance of thick organic offshore coatings10.1016/j.porgcoat.2020.105720 ↗
44. Wear of polyethylene and polyurethane elastomers used for components working in natural abrasive environments10.1016/j.polymertesting.2021.107247 ↗
45. Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study10.1111/jopr.13514 ↗
46. Hardness and surface roughness of differently processed denture base acrylic resins after immersion in simulated gastric acid10.1016/j.prosdent.2022.12.001 ↗
47. Mechanical properties of 3D printed denture base polymers10.1016/j.prosdent.2025.02.009 ↗
48. The use of nylon as a denture-base material10.1016/0300-5712(86)90097-7 ↗
49. In Vitro Evaluation of Adhesion of Candida albicans on CAD/CAM PMMA-Based Polymers10.1111/jopr.12942 ↗
50. Physical, Mechanical, and Anti-Biofilm Formation Properties of CAD-CAM Milled or 3D Printed Denture Base Resins: In Vitro Analysis10.1111/jopr.13554 ↗
51. Alqarawi, F.K., and Gad, M.M. (2024). Tendency of microbial adhesion to denture base resins: A systematic review. Front. Oral Health, 5.10.3389/froh.2024.1375186 ↗
52. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis10.1034/j.1600-0501.1996.070302.x ↗
53. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature10.1016/S0109-5641(97)80038-3 ↗
54. Effect of material characteristics and/or surface topography on biofilm development10.1111/j.1600-0501.2006.01353.x ↗
55. Schubert, A., Wassmann, T., Holtappels, M., Kurbad, O., Krohn, S., and Bürgers, R. (2019). Predictability of Microbial Adhesion to Dental Materials by Roughness Parameters. Coatings, 9.10.3390/coatings9070456 ↗
56. Rosentritt, M., Schmutzler, A., Hahnel, S., and Kurzendorfer-Brose, L. (2024). The Influence of CLSM Magnification on the Measured Roughness of Differently Prepared Dental Materials. Materials, 17.10.3390/ma17235954 ↗
57. The effect of dentifrice abrasion on denture topography and the subsequent retention of microorganisms on abraded surfaces10.1016/j.prosdent.2014.05.009 ↗
58. Oral prosthetic microbiology: Aspects related to the oral microbiome, surface properties, and strategies for controlling biofilms10.1080/08927014.2021.1912741 ↗
59. The effect of surface material, roughness and wettability on the adhesion and proliferation of Streptococcus gordonii, Fusobacterium nucleatum and Porphyromonas gingivalis10.1016/j.jds.2022.09.010 ↗
60. The oral microbiome: Diversity, biogeography and human health10.1038/s41579-023-00963-6 ↗
61. Applications, modifications, and manufacturing of polyetheretherketone (PEEK) in dental implantology: A comprehensive critical review10.1177/09506608251314251 ↗