journal article·2025-08-13Open access

Analysis of Insertion Torque of Orthodontic Mini-Implants Depending on the System and the Morphological Substrate

Tamara Rahela Ioana, Filip George Boeru, Ioana Mitruț, Anne-Marie Rauten, Mahmoud Elsaafin, Mihaela Ionescu, Ionela Elisabeta Staicu, Horia Octavian Manolea

Abstract

Orthodontic mini-implants are well-known anchorage devices and stand out as a particularly effective tool for ensuring maximum anchorage without relying on patient compliance. Therefore, it is necessary to understand what levels of torque strains remain in the physiological limits and can guarantee the stability of these mini-implants. The aim of this study was to investigate and measure the initial and final torque values of orthodontic mini-implants when placed perpendicular to the maxillary and mandibular bone surfaces. In our study, orthodontic mini-implants from different companies were inserted perpendicularly using different insertion torques on the plate of both maxillary and mandibular bones from pig specimens. The torque values were then analyzed. The results of this study highlight the need for continued research to analyze the ideal insertion torque of different types of mini-implants depending on the insertion area, in order to achieve clinical success of mini-implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental Implant Techniques and Outcomes · dental development and anomalies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Private Practice “Embrace”, 200618 Craiova, Romania

Department of Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Department of Orthodontics, Faculty of Dentistry, George Emil Palade University of Medicine and Pharmacy of Targu Mures, 540142 Targu Mures, Romania

Department of Medical Informatics and Biostatistics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Department of Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Funding

University of Medicine and Pharmacy of Craiova, Romania

References (54)

Show source-provided references
1. In vitro physical properties and clinical stability of reused orthodontic miniscrews: A systematic review and meta-analysis
2. Insertion torque and success of orthodontic mini-implants: A systematic review10.1016/j.ajodo.2012.06.013 ↗
3. The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)10.1016/j.heliyon.2023.e19858 ↗
4. Mini screw design and bone characterstics: Study of primary stability10.1016/j.ajodo.2012.03.029 ↗
5. Evaluation of Strain and Insertion Torque of Mini-implants at 90° and 45° Angulations on a Bone Model using Three-Dimensional Finite Element Analysis10.4103/ccd.ccd_725_21 ↗
6. Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: An in vitro study10.1590/2177-6709.29.2.e2423282.oar ↗
7. Antoniac, I., Manescu Paltanea, V., Antoniac, A., and Paltanea, G. (2023). Magnesium-based alloys with adapted interfaces for bone implants and tissue engineering. Regen. Biomater., 10.10.1093/rb/rbad095 ↗
8. Scanning electron microscope analysis of titanium alloy orthodontic implants10.37358/MP.17.2.4848 ↗
9. Comparative evaluation of biomechanical performance of titanium and stainless steel mini implants at different angulations in maxilla: A finite element analysis10.1177/0301574219863527 ↗
10. Comparison of primary stability of used and unused self-tapping and self-drilling orthodontic mini-implants10.17219/acem/169511 ↗
11. Miniscrew stability evaluated with computerized tomography scanning, American10.1016/j.ajodo.2008.03.024 ↗
12. Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure10.2319/100711-629.1 ↗
13. Placement and removal torque values of orthodontic miniscrew implants10.1016/j.ajodo.2010.11.017 ↗
14. Optimal implant stabilization in low density bone10.1034/j.1600-0501.2001.120501.x ↗
15. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants10.1111/j.1600-0501.2004.01041.x ↗
16. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
17. The miniature pig: A useful large animal model for dental and orofacial research10.1111/j.1601-0825.2006.01337.x ↗
18. Jin, Y., Yuan, X., Zhang, H., Jiang, Q., Fan, Q., Li, J., Lai, W., and Long, H. (2024). A rat model for microimplant-assisted rapid palatal expansion. Biochem. Biophys. Res. Commun., 741.10.1016/j.bbrc.2024.150964 ↗
19. Characterizing orthodontic mini-screws in the hard palate of pigs: An experimental and finite-element study10.1016/j.heliyon.2024.e24952 ↗
20. Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial10.2174/1874210601610010251 ↗
21. Insertion angle impact on primary stability of orthodontic mini-implants10.2319/100707-484.1 ↗
22. Primary stability of orthodontic mini-implants inserted into maxilla and mandible of swine10.1016/j.tripleo.2011.06.021 ↗
23. Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: A systematic review and meta-analysis10.1186/s40510-018-0225-1 ↗
24. In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts10.47162/RJME.62.3.16 ↗
25. Ioana, T.R., Boeru, F.G., Antoniac, I., Mitruț, I., Staicu, I.E., Rauten, A.M., Uriciuc, W.A., and Manolea, H.O. (2024). Surface Analysis of Orthodontic Mini-Implants after Their Clinical Use. J. Funct. Biomater., 15.10.3390/jfb15090244 ↗
26. Stasiak, M., and Adamska, P. (2023). Should Cone-Beam Computed Tomography Be Performed Prior to Orthodontic Miniscrew Placement in the Infrazygomatic Crest Area?-A Systematic Review. Biomedicines, 11.10.3390/biomedicines11092389 ↗
27. Assessment of Bone Thickness at the Infra Zygomatic Crest Region for Various Orthodontic Miniscrew Implant (OMSI) Insertion Angles: A Cone-Beam Computed Tomographic Study10.4274/TurkJOrthod.2023.2023.14 ↗
28. Mechanical stability of orthodontic miniscrew depends on a thread shape10.1016/j.jds.2021.11.010 ↗
29. Evaluation of expansion forces of five pure bone-borne maxillary expander designs anchored with orthodontic mini-implants: An in vitro study10.1177/14653125231152502 ↗
30. Labunet, A., Iosif, C., Kui, A., Vigu, A., and Sava, S. (2024). Miniscrew-Assisted Rapid Palatal Expansion: A Scoping Review of Influencing Factors, Side Effects, and Soft Tissue Alterations. Biomedicines, 12.10.3390/biomedicines12112438 ↗
31. Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles10.1093/ejo/cjs095 ↗
32. Effects of the diameter and shape of orthodontic mini-implants on microdamage to the cortical bone10.1016/j.ajodo.2010.02.019 ↗
33. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: A systematic review10.1186/s13643-016-0227-3 ↗
34. Comparative evaluation of primary stability of two different types of orthodontic mini-implants10.4103/jpbs.JPBS_604_20 ↗
35. Recommended placement torque when tightening an orthodontic mini-implant10.1111/j.1600-0501.2005.01211.x ↗
36. Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws10.1016/S1010-5182(98)80035-8 ↗
37. Stability of smooth and rough mini-implants: Clinical and biomechanical evaluation-an in vivostudy10.1590/2177-6709.20.5.035-042.oar ↗
38. Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters an experimental laboratory study10.1186/s40510-021-00352-w ↗
39. Scribante, A., Montasser, M.A., Radwan, E.S., Bernardinelli, L., Alcozer, R., and Gandini, P. (2018). Reliability of orthodontic miniscrews bending and maximum load of different Ti-6Al-4V titanium and stainless steel temporary anchorage devices (TADs). Materials, 11.10.3390/ma11071138 ↗
40. Structural resistance of orthodontic mini-screws inserted for extra-alveolar anchorage10.54589/aol.34/1/027 ↗
41. Effect of mini-implant diameter on fracture risk and self-drilling efficacy10.1016/j.ajodo.2011.06.016 ↗
42. Fracture resistance of orthodontic mini-implants: A biomechanical in vitro study10.1093/ejo/cjq151 ↗
43. Miniscrew-assisted rapid palatal expansion (MARPE): How to achieve greater stability. In vitro study10.1590/2177-6709.26.1.e211967.oar ↗
44. Effect of screw diameter on orthodontic skeletal anchorage10.1016/j.ajodo.2007.07.031 ↗
45. Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs10.1016/j.ajodo.2003.12.023 ↗
46. Factors affecting stresses in cortical bone around miniscrew implants: A three-dimensional finite element study10.2319/111011-696.1 ↗
47. 15-year study of osseointegrated implants in the treatment of the edentulous jaw10.1016/S0300-9785(81)80077-4 ↗
48. The long-term efficacy of current dental implants. A review and proposed criteria for success
49. Factors associated with the stability of tita niumscrewsplaced in the posterior region for orthodontic anchor age10.1016/S0889-5406(03)00565-1 ↗
50. Evaluation of reused orthodontic mini-implants on stability: An in-vivo study10.1016/j.ajodo.2021.06.024 ↗
51. Effect of miniscrew placement torque on resistance to miniscrew movement under load10.1016/j.ajodo.2011.04.017 ↗
52. Validating implant torque limiting devices with a custom tool: A dental technique10.1016/j.prosdent.2020.03.003 ↗
53. Skvirsky, Y., Giladi, H.Z., Rizzante, F.A.P., Teich, S.T., and Gutmacher, Z. (J. Prosthet. Dent., 2025). Measurements of trueness and precision of various dental torque wrenches: An in vitro study, J. Prosthet. Dent., In Press.10.1016/j.prosdent.2025.06.023 ↗
54. Testing and calibrating the mechanical-type toggle torque wrenches used in implant dentistry: A dental technique10.1016/j.prosdent.2019.04.021 ↗