journal article·2024-05-07Open access

Fracture Resistance of a Bone-Level Two-Piece Zirconia Oral Implant System—The Influence of Artificial Loading and Hydrothermal Aging

Ralf J. Kohal, Ellen Riesterer, Kirstin Vach, Sebastian B. M. Patzelt, Aljaž Iveković, Lara Einfalt, Andraž Kocjan, Anna-Lena Hillebrecht

Abstract

Preclinical and clinical research on two-piece zirconia implants are warranted. Therefore, we evaluated the in vitro fracture resistance of such a zirconia oral implant system. The present study comprised 32 two-piece zirconia implants and abutments attached to the implants using a titanium (n = 16) or a zirconia abutment screw (n = 16). Both groups were subdivided (n = 8): group T-0 comprised implants with a titanium abutment screw and no artificial loading; group T-HL was the titanium screw group exposed to hydro-thermomechanical loading in a chewing simulator; group Z-0 was the zirconia abutment screw group with no artificial loading; and group Z-HL comprised the zirconia screw group with hydro-thermomechanical loading. Groups T-HL and Z-HL were loaded with 98 N and aged in 85 °C hot water for 107 chewing cycles. All samples were loaded to fracture. Kruskal–Wallis tests were executed to assess the loading/bending moment group differences. The significance level was established at a probability of 0.05. During the artificial loading, there was a single occurrence of an implant fracture. The mean fracture resistances measured in a universal testing machine were 749 N for group T-0, 828 N for group Z-0, 652 N for group T-HL, and 826 N for group Z-HL. The corresponding bending moments were as follows: group T-0, 411 Ncm; group Z-0, 452 Ncm; group T-HL, 356 Ncm; and group Z-HL, 456 Ncm. There were no statistically significant differences found between the experimental groups. Therefore, the conclusion was that loading and aging did not diminish the fracture resistance of the evaluated implant system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany

Medical Center—University of Freiburg, Institute of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany

Private Dental Clinic, 78658 Zimmern ob Rottweil, Germany

Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia

Jožef Stefan International Postgraduate School, Jamova 39, 1000 Ljubljana, Slovenia

Funding

Z-Systems AG, Oensingen, Switzerland

References (65)

Show source-provided references
1. Clinical Outcomes of Zirconia Dental Implants: A Systematic Review10.1177/0022034516664043 ↗
2. Group 2 ITI Consensus Report: Prosthodontics and Implant Dentistry10.1111/clr.13298 ↗
3. Two-Piece Zirconia Implants in the Posterior Mandible and Maxilla: A Cohort Study with a Follow-up Period of 9 Years10.1111/clr.14005 ↗
4. Prospective Clinical Multicenter Study Evaluating the 5-Year Performance of Zirconia Implants in Single-Tooth Gaps10.11607/jomi.9289 ↗
5. Osseointegrated Oral Implants. A Swedish Multicenter Study of 8139 Consecutively Inserted Nobelpharma Implants10.1902/jop.1988.59.5.287 ↗
6. Clinical Trials on Implants in Regenerated Bone10.1902/annals.1997.2.1.329 ↗
7. Systematic Review of the Survival Rate and the Incidence of Biological, Technical, and Aesthetic Complications of Single Crowns on Implants Reported in Longitudinal Studies with a Mean Follow-up of 5 Years10.1111/j.1600-0501.2012.02547.x ↗
8. A Systematic Review of the Survival and Complication Rates of Implant-Supported Fixed Dental Prostheses (FDPs) after a Mean Observation Period of at Least 5 Years10.1111/j.1600-0501.2012.02546.x ↗
9. Suspected Association of an Allergic Reaction with Titanium Dental Implants: A Clinical Report10.1016/S0022-3913(08)60233-4 ↗
10. Titanium Allergy in Dental Implant Patients: A Clinical Study on 1500 Consecutive Patients10.1111/j.1600-0501.2008.01544.x ↗
11. On Inflammation-Immunological Balance Theory-A Critical Apprehension of Disease Concepts around Implants: Mucositis and Marginal Bone Loss May Represent Normal Conditions and Not Necessarily a State of Disease10.1111/cid.12711 ↗
12. Comino-Garayoa, R., Cortés-Bretón Brinkmann, J., Peláez, J., López-Suárez, C., Martínez-González, J.M., and Suárez, M.J. (2020). Allergies to Titanium Dental Implants: What Do We Really Know about Them? A Scoping Review. Biology, 9.10.3390/biology9110404 ↗
13. Allergic Contact Dermatitis Caused by Titanium Screws and Dental Implants10.1016/j.jpor.2015.12.004 ↗
14. A Clinical Case Report of a Potential Acute Allergic Reaction with Titanium Dental Implant
15. Poli, P.P., de Miranda, F.V., Polo, T.O.B., Santiago Júnior, J.F., Lima Neto, T.J., Rios, B.R., Assunção, W.G., Ervolino, E., Maiorana, C., and Faverani, L.P. (2021). Titanium Allergy Caused by Dental Implants: A Systematic Literature Review and Case Report. Materials, 14.10.3390/ma14185239 ↗
16. Evaluation of Removal Torque and Internal Surface Alterations in Frictional Morse Taper Connections After Mechanical Loading Associated or Not with Oral Biofilm10.11607/jomi.8483 ↗
17. Increased Levels of Dissolved Titanium Are Associated With Peri-Implantitis—A Cross-Sectional Study10.1902/jop.2016.160524 ↗
18. De la Garza-Ramos, M.A., Estupiñan-Lopez, F.H., Gaona-Tiburcio, C., Beltrán-Novelo, L.G., Zambrano-Robledo, P., Cabral-Miramontes, J., and Almeraya-Calderón, F. (2020). Electrochemical Behavior of Ti6Al4V Alloy Used in Dental Implants Immersed in Streptococcus Gordonii and Fusobacterium Nucleatum Solutions. Materials, 13.10.3390/ma13184185 ↗
19. Sclerostin Is a Promising Therapeutic Target for Oral Inflammation and Regenerative Dentistry10.1186/s12967-022-03417-4 ↗
20. Unpredictable Electrochemical Processes in Ti Dental Implants: The Role of Ti Ions and Inflammatory Products10.1021/acsabm.3c00235 ↗
21. Delgado-Ruiz, R., and Romanos, G. (2018). Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review. Int. J. Mol. Sci., 19.10.3390/ijms19113585 ↗
22. Surface Damage of Dental Implant Systems and Ions Release after Exposure to Fluoride and Hydrogen Peroxide10.1111/jre.12603 ↗
23. Effect of Implant Cleaning on Titanium Particle Dissolution and Cytocompatibility10.1002/JPER.20-0186 ↗
24. In Vitro Evaluation of the Effects of Multiple Oral Factors on Dental Implants Surfaces10.1563/aaid-joi-D-15-00165 ↗
25. Multifaceted Roles of Environmental Factors toward Dental Implant Performance: Observations from Clinical Retrievals and in Vitro Testing10.1016/j.dental.2018.08.299 ↗
26. Evaluation of Oral Microbial Corrosion on the Surface Degradation of Dental Implant Materials10.1002/JPER.18-0110 ↗
27. Tissue Compatibility and Stability of a New Zirconia Ceramic in Vivo10.1016/0022-3913(92)90338-B ↗
28. Interface Histology of Unloaded and Early Loaded Partially Stabilized Zirconia Endosseous Implant in Initial Bone Healing10.1016/0022-3913(93)90289-Z ↗
29. Comparison between Freestanding and Tooth-Connected Partially Stabilized Zirconia Implants after Two Years’ Function in Monkeys: A Clinical and Histologic Study10.1016/S0022-3913(98)70031-9 ↗
30. Inflammatory Infiltrate, Microvessel Density, Nitric Oxide Synthase Expression, Vascular Endothelial Growth Factor Expression, and Proliferative Activity in Peri-Implant Soft Tissues around Titanium and Zirconium Oxide Healing Caps10.1902/jop.2006.77.1.73 ↗
31. Matrix Metalloproteinases 2, 3, 8, 9, and 13 in the Peri-Implant Soft Tissues around Titanium and Zirconium Oxide Healing Caps10.11607/jomi.2502 ↗
32. Peri-Implant Bone Response to Retrieved Human Zirconia Oral Implants after a 4-Year Loading Period: A Histologic and Histomorphometric Evaluation of 22 Cases10.1002/jbm.b.33512 ↗
33. Cellular Transcriptional Response to Zirconia-Based Implant Materials10.1016/j.dental.2016.12.005 ↗
34. Clinical Evaluation and Patient Related Outcomes of One- and Two-Piece Zirconia Implants at Five Years of Loading: A Case Series Study10.1111/jerd.13002 ↗
35. Clinical Outcomes of All-Ceramic Single Crowns and Fixed Dental Prostheses Supported by Ceramic Implants: A Systematic Review and Meta-Analyses10.1111/clr.13871 ↗
36. Peri-Implant Mucositis
37. In Vitro Performance of Two-Piece Zirconia Implant Systems for Anterior Application10.1016/j.dental.2016.03.028 ↗
38. Bethke, A., Pieralli, S., Kohal, R.-J., Burkhardt, F., von Stein-Lausnitz, M., Vach, K., and Spies, B.C. (2020). Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. Materials, 13.10.3390/ma13030562 ↗
39. (2017). Dentistry—Implants—Dynamic Fatigue Test for Endosseous Dental Implants. Standard No. ISO 14801:2016.
40. Quality Assessment of the Cortical Bone of the Human Mandible10.1016/S8756-3282(02)00921-3 ↗
41. Kohal, R.-J., Schikofski, T., Adolfsson, E., Vach, K., Patzelt, S.B.M., Nold, J., and Wemken, G. (2023). Fracture Resistance of a Two-Piece Zirconia Implant System after Artificial Loading and/or Hydrothermal Aging-An In Vitro Investigation. J. Funct. Biomater., 14.10.3390/jfb14120567 ↗
42. An in Vitro Load Evaluation of a Conical Implant System with 2 Abutment Designs and 3 Different Retaining-Screw Alloys
43. In Vivo Forces on Implants Influenced by Occlusal Scheme and Food Consistency
44. The Wear of Dental Amalgam in an Artificial Mouth: A Clinical Correlation10.1016/S0109-5641(85)80050-6 ↗
45. The Wear of a Posterior Composite in an Artificial Mouth: A Clinical Correlation10.1016/S0109-5641(86)80034-3 ↗
46. In-vitro-Testverfahren zur Evaluation dentaler Restaurationssysteme. 3. Korrelation mit In-vivo-Resultaten
47. An Artificial Oral Environment for Testing Dental Materials10.1109/10.133228 ↗
48. Influence of Stress Simulation Parameters on the Fracture Strength of All-Ceramic Fixed-Partial Dentures10.1016/j.dental.2005.04.024 ↗
49. Time-Frequency Analysis of Chewing Activity in the Natural Environment10.1177/0022034511416669 ↗
50. Influence of Hydrothermal and Mechanical Conditions on the Strength of Zirconia10.1016/j.actbio.2010.07.025 ↗
51. Low Temperature Degradation -Aging- of Zirconia: A Critical Review of the Relevant Aspects in Dentistry10.1016/j.dental.2010.04.006 ↗
52. Transformation Toughening in Zirconia-Containing Ceramics10.1111/j.1151-2916.2000.tb01221.x ↗
53. On the Kinetics and Impact of Tetragonal to Monoclinic Transformation in an Alumina/Zirconia Composite for Arthroplasty Applications10.1016/j.biomaterials.2009.06.022 ↗
54. Complexity of the Relationships between the Sintering-Temperature-Dependent Grain Size, Airborne-Particle Abrasion, Ageing and Strength of 3Y-TZP Ceramics10.1016/j.dental.2015.12.004 ↗
55. In Vivo Ageing of Zirconia Dental Ceramics—Part II: Highly-Translucent and Rapid-Sintered 3Y-TZP10.1016/j.dental.2020.11.023 ↗
56. Ageing Kinetics and Strength of Airborne-Particle Abraded 3Y-TZP Ceramics10.1016/j.dental.2017.04.014 ↗
57. Microstructural Changes in Ground 3Y-TZP and Their Effect on Mechanical Properties10.1016/j.actamat.2011.07.024 ↗
58. Surface Grain Size and Texture after Annealing Ground Zirconia10.1016/j.jeurceramsoc.2015.12.022 ↗
59. Impact of Sandblasting on the Mechanical Properties and Aging Resistance of Alumina and Zirconia Based Ceramics10.1016/j.jeurceramsoc.2017.10.050 ↗
60. Effect of Sandblasting and Residual Stress on Strength of Zirconia for Restorative Dentistry Applications10.1016/j.jmbbm.2013.09.004 ↗
61. Ceramics for Medical Applications: A Picture for the next 20 Years10.1016/j.jeurceramsoc.2008.08.025 ↗
62. The Effect of Surface Grinding and Sandblasting on Flexural Strength and Reliability of Y-TZP Zirconia Ceramic10.1016/S0109-5641(99)00070-6 ↗
63. Effect of Airborne-Particle Abrasion of Yttria-Containing Zirconia Dental Ceramics on Mechanical Properties before and after Regeneration Firing10.1016/j.jeurceramsoc.2022.05.010 ↗
64. Determination of interfacial properties of thermal barrier coatings by shear test and inverse finite element method10.1016/j.actamat.2010.07.013 ↗
65. (2015). Implants for Surgery: Ceramic Materials Based on Yttria-Stabilized Tetragonal Zirconia (Y-TZP). Standard No. ISO 13356:2015.