journal article·2024-11-13Open access

The Effect of Micro-Computed Tomography Thresholding Methods on Bone Micromorphometric Analysis

Arda Buyuksungur, Bence Tamás Szabó, Adrienn Dobai, Kaan Orhan

Journal of Functional Biomaterials· Volume 15· Issue 11

Abstract

Bone micromorphometric parameters are generally analyzed with micro CT to reveal two- and three-dimensional structures. These parameters are generally used for new bone formation studies such as tissue engineering and biomaterials studies. Different threshold methods are used for the image segmentation of bone micromorphometric parameters. However, these different threshold methods provide different results for the bones analyzed. This study aimed to compare thresholding methods to evaluate bone micromorphometric parameters in the mouse bone. A dataset containing 15 mouse tibia was used to analyze the different thresholding methods for bone micromorphometric parameter analysis. These threshold methods were used to analyze the mouse tibia (n = 15) with thresholded bones. The threshold methods and the analysis were used directly from CTAn (Bruker Micro-CT). The results were compared between the threshold methods, which included bone volume, trabecular number, connectivity, trabecular separation, and other parameters. There was agreement to some extent for all bone micromorphometric analyses using the different thresholding methods. The results showed that the thresholding method showed good agreement for connectivity and trabecular thickness, but the other parameters showed limited agreement. The evaluation of threshold methods allows for the comparison of image segmentation and the quantification of mouse tibia micromorphometric parameters. This study may enable the analysis of bone micromorphometric parameters using the relatively close threshold method in image segmentation across different research groups.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Radiography and Imaging · Medical Imaging Techniques and Applications · Bone health and osteoporosis research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Basic Medical Sciences, Ankara University, 06100 Ankara, Türkiye

Department of Oral Diagnostics, Faculty of Dentistry, Semmelweis University, 1088 Budapest, Hungary

Department of Dentomaxillofacial Radiology, Ankara University, 06100 Ankara, Türkiye

References (29)

Show source-provided references
1. Orhan, K. (2020). Fundamentals of Micro-CT Imaging. Micro-computed Tomography (Micro-CT) in Medicine and Engineering, Springer.10.1007/978-3-030-16641-0 ↗
2. An efficient multilevel image thresholding method based on improved heap-based optimizer10.1038/s41598-023-36066-8 ↗
3. The Micro-CT Analysis of the Structural Parameters of Collagen-based Porous Scaffolds: The Influence of Image Processing and Binarization10.1093/micmic/ozac024 ↗
4. Dey, N., Ashour, A.S., Shi, F., and Balas, E.S. (2018). State-of-the-Art of Level-Set Methods in Segmentation and Registration of Spectral Domain Optical Coherence Tomographic Retinal Images. Soft Computing Based Medical Image Analysis, Academic Press.
5. Phase Segmentation of Uncured Prepreg X-Ray CT Micrographs10.1016/j.compositesa.2021.106527 ↗
6. Recent advances in CT image reconstruction10.1007/s40134-012-0003-7 ↗
7. Review of porosity uncertainty estimation methods in computed tomography dataset10.1088/1361-6501/ac1b40 ↗
8. Segmentation of X-ray tomography images of compacted soils10.1007/s40948-021-00322-w ↗
9. Damage Evolution of Onnagawa Shale by Postmortem Thresholding of X-Ray Computed Tomography10.1029/2021JB022056 ↗
10. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice10.1016/j.bonr.2016.05.006 ↗
11. Segmentation techniques for analysis of bone by three-dimensional computed tomographic imaging10.3233/THC-1998-65-608 ↗
12. Guidelines for assessment of bone microstructure in rodents using micro–computed tomography10.1002/jbmr.141 ↗
13. Comparison of X-ray micro-tomography measurements of densities and porosity principally to values measured by mercury porosimetry for carbon-carbon composites10.1016/j.carbon.2009.11.047 ↗
14. A parametric study of segmentation thresholds for X-ray CT porosity characterization in composite materials10.1016/j.compositesa.2019.04.029 ↗
15. The effectiveness of global thresholding techniques in segmenting two-phase porous media10.1016/j.conbuildmat.2017.03.046 ↗
16. Observer-dependent variability of the thresholding step in the quantitative analysis of soil images and X-ray microtomography data10.1016/j.geoderma.2010.03.015 ↗
17. A comparative performance study of several global thresholding techniques for segmentation10.1016/0734-189X(90)90053-X ↗
18. Investigation of pore structure in cobalt chrome additively manufactured parts using X-ray computed tomography and three-dimensional image analysis
19. Zhang, Y., He, Z., Fan, S., He, K., and Li, C. (2008, January 27–30). Automatic Thresholding of Micro-CT Trabecular Bone Images. Proceedings of the 2008 International Conference on BioMedical Engineering and Informatics, Sanya, China.10.1109/BMEI.2008.13 ↗
20. Micro-CT—A digital 3D microstructural voyage into scaffolds: A systematic review of the reported methods and results10.1186/s40824-018-0136-8 ↗
21. Evaluation of threshold values for root canal filling voids in micro-CT and nano-CT images10.1155/2018/9437569 ↗
22. Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars10.1259/dmfr.20200503 ↗
23. Evaluation of curved root canals filled with a new bioceramic sealer: A microcomputed tomographic study using images with different voxel sizes and segmentation methods10.1002/jemt.23855 ↗
24. The imaging of root canal obturation using micro-CT10.1111/j.1365-2591.2005.00990.x ↗
25. Effect of grayscale threshold on X-ray computed tomography reconstruction of gas diffusion layers in polymer electrolyte membrane fuel cells10.1016/j.heliyon.2024.e29378 ↗
26. How image-processing parameters can influence the assessment of dental materials using micro-CT10.5624/isd.2020.50.2.161 ↗
27. Abdominal CT body composition thresholds using automated AI tools for predicting 10-year adverse outcomes10.1148/radiol.220574 ↗
28. Moreau, N., Rousseau, C., Fourcade, C., Santini, G., Ferrer, L., Lacombe, M., Guillerminet, C., Jezequel, P., Campone, M., and Normand, N. (2021, January 15–19). Comparison between threshold-based and deep learning-based bone segmentation on whole-body CT images. Proceedings of the Medical Imaging 2021: Computer-Aided Diagnosis, Online.10.1117/12.2580892 ↗
29. Novel thresholding method and convolutional neural network for fiber volume content determination from 3D μCT images10.1016/j.ndteint.2024.103067 ↗