journal article·2023-06-02Open access

Pressure Analysis in Rigid and Flexible Real Arteriovenous Fistula with Thickness Variation In Vitro

Jonhattan Ferreira Rangel, Willyam Brito de Almeida Santos, Thércio Henrique de Carvalho Costa, Kleiber Lima de Bessa, José Daniel Diniz Melo

Abstract

An arteriovenous fistula (AVF) is the access most recommended by several authors. However, its manufacture and use can cause several problems in the short, medium and long term. The study of fluid dynamics related to the structure of the AVF can provide information necessary for the reduction of these problems and a better quality of life for patients. The present study analyzed pressure variation in a rigid and flexible (thickness variation) model of AVFs manufactured based on patient data. A computed tomography was performed from which the geometry of the AVF was removed. This was treated and adapted to the pulsatile flow bench. Bench tests with simulation of systolic–diastolic pulse showed higher pressure peaks in the rigid AVF followed by the flexible model with 1 mm thickness. The inflection of the pressure values of the flexible AVF in relation to the rigid one was observed, being more expressive in the flexible AVF of 1 mm. The 1 mm flexible AVF presented an average pressure close to the physiological one and a smaller pressure drop, showing that this AVF model presents the best condition among the three to serve as a basis for the development of an AVF substitute.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Central Venous Catheters and Hemodialysis · Vascular Malformations Diagnosis and Treatment · Vascular Procedures and Complications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Materials Science and Engineering Post-Graduation, Department of Materials Science and Engineering, Federal University of Rio Grande do Norte—UFRN, Natal 59078-970, Brazil

Mechanical Post-Graduation, Department of Mechanical Engineering, Federal University of Rio Grande do Norte—UFRN, Natal 59078-970, Brazil

Funding

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)

References (23)

Show source-provided references
1. A validated patient-specific FSI model for vascular access in haemodialysis10.1007/s10237-017-0973-8 ↗
2. Hemodynamic study of arteriovenous fistulas for hemodialysis access10.1258/vasc.2011.201204 ↗
3. Future research directions to improve fistula maturation and reduce access failure10.1053/j.semvascsurg.2016.08.005 ↗
4. Analysis of Blood Flow Characteristics in a Model of a Mature Side-to-Side Arteriovenous Fistula10.1111/aor.12879 ↗
5. (2022, July 19). Types of Arteriovenous Fistulas, Available online: https://www.ncbi.nlm.nih.gov/books/NBK493195/.
6. Rai, V., and Agrawal, D.K. (2022). Transcriptomic Analysis Identifies Differentially Expressed Genes Associated with Vascular Cuffing and Chronic Inflammation Mediating Early Thrombosis in Arteriovenous Fistula. Biomedicines, 10.10.3390/biomedicines10020433 ↗
7. When Is Arteriovenous Fistula Dangerous for Hemodialysis Patients?10.3390/kidneydial2010010 ↗
8. Arteriovenous fistulas for hemodialysis: Brief review and current problems10.1177/11297298211007720 ↗
9. Influence of Wall Compliance on the Flow Patterns in a Patient-Specific Brachio-Cephalic Arterio-Venous Fistula10.3390/biomechanics2020014 ↗
10. In Vivo Validation of the In Silico Predicted Pressure Drop Across an Arteriovenous Fistula10.1007/s10439-015-1295-6 ↗
11. Longitudinal Study of Remodeling in a Revised Peripheral Artery Bypass Graft Using 3D Ultrasound Imaging and Computational Hemodynamics
12. Biological and Physical Factors Involved in the Maturation of Arteriovenous Fistula for Hemodialysis10.1007/s13239-017-0323-0 ↗
13. Numerical Evaluation and Experimental Validation of Pressure Drops Across a Patient-Specific Model of Vascular Access for Hemodialysis10.1007/s13239-013-0162-6 ↗
14. Why don’t fistulas mature?10.1038/sj.ki.5001747 ↗
15. Natural Vascular Scaffolding Treatment Promotes Outward Remodeling During Arteriovenous Fistula Development in Rats10.3389/fbioe.2021.622617 ↗
16. Increased venous proinflammatory gene expression and intimal hyperplasia in an aorto-caval fistula model in the rat10.1016/S0002-9440(10)64339-8 ↗
17. Healthy and diseased in vitro models of vascular systems10.1039/D0LC00464B ↗
18. Santos, W.B.A. (2021). Análise do Escoamento Pulsátil em Fístula Arteriovenosa com Variação do Ângulo de Anastomose In Vitro e In Silico. [Master’s Thesis, Federal University of Rio Grande do Norte].
19. Serial analysis of lumen geometry and hemodynamics in human arteriovenous fistula for hemodialysis using magnetic resonance imaging and computational fluid dynamics10.1016/j.jbiomech.2012.09.005 ↗
20. Longitudinal assessment of hemodynamic endpoints in predicting arteriovenous fistula maturation
21. Influence of temporal variation in wall shear stress on intima-media thickening in arteriovenous fistulae10.1111/sdi.12045 ↗
22. A Review of the Hemodynamic Factors Believed to Contribute to Vascular Access Dysfunction10.1007/s13239-017-0307-0 ↗
23. Comparison of Pulsatile Pressure Flow through a Specific Patient’s Rigid and Deformable Arteriovenous Fistula: In Vitro Study