journal article·2025-04-07Open access

Evaluation of Biomechanical Effects of Mandible Arch Types in All-on-4 and All-on-5 Dental Implant Design: A 3D Finite Element Analysis

Sema Nur Sevinç Gül, Fahri Murat, Abdullah Tahir Şensoy

Abstract

This study evaluates the biomechanical effects of different implant configurations in various mandibular arch types using finite element analysis (FEA). Stress distribution and deformation patterns were analyzed under different loading conditions in square, U-shaped, and V-shaped arches. The results indicate that increasing the number of implants generally reduces cortical bone stress, particularly in U and V arches, while implant-level stress tends to increase. Under molar loading, cortical bone stress in the square arch decreased by 16.9% (from 90.61 MPa to 75.27 MPa) with the All-on-5 system, while implant stress in the V arch dropped by 46.26% (from 142.35 MPa to 76.5 MPa). Additionally, the cantilever effect in All-on-4 configurations resulted in higher stress on the prosthesis and implants, particularly in V arches. While the All-on-5 system provided better load distribution, the study highlights the importance of optimizing implant positioning based on mandibular anatomy. Despite limitations such as the use of static forces and standardized arch types, these findings offer valuable insights into the biomechanical performance of full-arch implant rehabilitations, supporting future clinical applications and research.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Periodontology, Faculty of Dentistry, Atatürk University, 25240 Erzurum, Türkiye

Department of Mechanical Engineering, Faculty of Engineering and Architecture, Erzurum Technical University, 25050 Erzurum, Türkiye

Faculty of Mechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands

Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Samsun University, 55420 Samsun, Türkiye

Funding

Delft University of Technology

References (41)

Show source-provided references
1. Dimensional ridge alterations following tooth extraction. An experimental study in the dog10.1111/j.1600-051X.2005.00642.x ↗
2. Influence of Night-Time of Denture Wearing on the Rate of Alveolar Ridge Resorption in Complete Denture Wearers. A One-Year Study
3. A 5-Year Retrospective Analysis of Biologic and Prosthetic Complications Associated with Single-Tooth Endosseous Dental Implants: Practical Applications10.1002/cap.10155 ↗
4. Di Fiore, A., Montagner, M., Sivolella, S., Stellini, E., Yilmaz, B., and Brunello, G. (2022). Peri-Implant Bone Loss and Overload: A Systematic Review Focusing on Occlusal Analysis through Digital and Analogic Methods. J. Clin. Med., 11.10.3390/jcm11164812 ↗
5. The Role of Occlusion in the Dental Implant and Peri-implant Condition: A Review10.2174/1874210601610010594 ↗
6. ‘All-on-Four’ Immediate-Function Concept with Brånemark System® Implants for Completely Edentulous Mandibles: A Retrospective Clinical Study10.1111/j.1708-8208.2003.tb00010.x ↗
7. Tilted implants for the rehabilitation of edentulous jaws: A systematic review10.1111/j.1708-8208.2010.00288.x ↗
8. ‘All-on-4’ Immediate-Function Concept for Completely Edentulous Maxillae: A Clinical Report on the Medium (3 Years) and Long-Term (5 Years) Outcomes
9. All-on-4® Treatment Concept for the Rehabilitation of the Completely Edentulous Mandible: A 7-Year Clinical and 5-Year Radiographic Retrospective Case Series with Risk Assessment for Implant Failure and Marginal Bone Level
10. Implant-bone load transfer mechanisms in complete-arch prostheses supported by four implants: A three-dimensional finite element approach10.1016/S0022-3913(13)60004-9 ↗
11. A Retrospective Analysis of 800 Brånemark System Implants Following the All-on-FourTM Protocol10.1111/jopr.12089 ↗
12. Effect of exposure rates with customized versus conventional titanium mesh on guided bone regeneration: Systematic review and meta-analysis10.1563/aaid-joi-D-20-00200 ↗
13. Analysis of technical complications and risk factors for failure of combined tooth-implant-supported fixed dental prostheses10.1111/cid.12927 ↗
14. The All-on-4 treatment concept for the rehabilitation of the completely edentulous mandible: A longitudinal study with 10 to 18 years of follow-up10.1111/cid.12769 ↗
15. Grandi, T., and Signorini, L. (2022). Rehabilitation of the Completely Edentulous Mandible by All-on-Four Treatment Concept: A Retrospective Cohort Study with Up to 10 Years Follow-Up. Medicina, 58.10.3390/medicina58010010 ↗
16. Sun, X., Cheng, K., Liu, Y., Ke, S., Zhang, W., Wang, L., and Yang, F. (2023). Biomechanical comparison of all-on-4 and all-on-5 implant-supported prostheses with alteration of anterior-posterior spread: A three-dimensional finite element analysis. Front. Bioeng. Biotechnol., 11.10.3389/fbioe.2023.1187504 ↗
17. An application of finite element method in material selection for dental implant crowns10.1515/bmt-2020-0232 ↗
18. Finite Element Stress Analysis of Applied Forces to Implants and Supporting Tissues Using the ‘All-on-Four’ Concept with Different Occlusal Schemes10.1111/jopr.13004 ↗
19. Evaluation of Stress in Tilted Implant Concept with Variable Diameters in the Atrophic Mandible: Three-Dimensional Finite Element Analysis10.1563/aaid-joi-D-19-00066 ↗
20. Biomechanical comparison of implant inclinations and load times with the all-on-4 treatment concept: A three-dimensional finite element analysis10.1080/10255842.2019.1572120 ↗
21. In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants10.1034/j.1600-0501.1996.070209.x ↗
22. Berzaghi, A., Testori, T., Scaini, R., and Bortolini, S. (2025). Occlusion and Biomechanical Risk Factors in Implant-Supported Full-Arch Fixed Dental Prostheses—Narrative Review. J. Pers. Med., 15.10.3390/jpm15020065 ↗
23. Resnik, R. (2021). Misch’s Contemporary Implant Dentistry, Mosby.
24. Comparison between all-on-four and all-on-six treatment concepts and framework material on stress distribution in atrophic maxilla: A prototyping guided 3D-FEA study10.1016/j.msec.2016.07.059 ↗
25. Influence of implants number on the biomechanical behavior of implant-supported complete prosthesis: A 3D finite element analysis10.1016/j.heliyon.2023.e17956 ↗
26. Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept10.1016/j.jpor.2010.04.004 ↗
27. Human ex vivo bone tissue strains around immediately-loaded implants supporting mandibular fixed prostheses10.1097/ID.0b013e3181990927 ↗
28. Kammoun, Y., El sharkawy, A., Khamis, M., and Fahmy, R. (2022). Radiographic Assessment of Bone Level Changes Around Four Implants Supporting Immediately Loaded Mandibular Screw-retained Prosthesis. Alex. Dent. J.10.21608/adjalexu.2021.47381.1114 ↗
29. Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis10.11607/jomi.6201 ↗
30. Forces and moments on Branemark implants
31. Tilting of posterior mandibular and maxillary implants for improved prosthesis support
32. Valente, F., Marrocco, A., and Falcinelli, C. (2025). Impact of physiological and non-physiological loading scenarios and crown material on periimplant bone stress distribution: A 3D finite element study. J. Mech. Behav. Biomed. Mater., 163.10.1016/j.jmbbm.2025.106894 ↗
33. Tilted and short implants supporting fixed prosthesis in an atrophic maxilla: A 3D-FEA biomechanical evaluation10.1111/cid.12129 ↗
34. Prediction at long-term condyle screw fixation of temporomandibular joint implant: A numerical study10.1016/j.jcms.2015.02.013 ↗
35. Three-Dimensional Nonlinear Contact Finite Element Analysis of Mandibular All-on-4 Design10.1563/AAID-JOI-D-13-00121 ↗
36. Biomechanical comparison of axial and tilted implants for mandibular full-arch fixed prostheses
37. Printing tissue-engineered scaffolds made of polycaprolactone and nano-hydroxyapatite with mechanical properties appropriate for trabecular bone substitutes10.1186/s12938-023-01135-6 ↗
38. Retention of mechanical properties and cytocompatibility of a phosphate-based glass fiber/polylactic acid composite10.1002/jbm.b.31182 ↗
39. Application of finite element analysis in implant dentistry: A review of the literature10.1067/mpr.2001.115251 ↗
40. Implant biomechanics in grafted sinus: A finite element analysis10.1563/0.674.1 ↗
41. Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor10.1016/j.prosdent.2004.10.001 ↗