journal article·2024-10-01Open access

Randomized Clinical Trial: Bone Bioactive Liquid Improves Implant Stability and Osseointegration

Ashraf Al Madhoun, Khaled Meshal, Neus Carrió, Eduard Ferrés-Amat, Elvira Ferrés-Amat, Miguel Barajas, Ana Leticia Jiménez-Escobar, Areej Said Al-Madhoun, Alaa Saber, Yazan Abou Alsamen, Carles Marti, Maher Atari

Journal of Functional Biomaterials· Volume 15· Issue 10

Abstract

Implant stability can be compromised by factors such as inadequate bone quality and infection, leading to potential implant failure. Ensuring implant stability and longevity is crucial for patient satisfaction and quality of life. In this multicenter, randomized, double-blind clinical trial, we assessed the impact of a bone bioactive liquid (BBL) on the Galaxy TS implant’s performance, stability, and osseointegration. We evaluated the impact stability, osseointegration, and pain levels using initial stability quotient (ISQ) measurements, CBCT scans, and pain assessment post-surgery. Surface analysis was performed using scanning electron microscopy (SEM) and atomic force microscopy (AFM). In vitro studies examined the BBL’s effects on dental pulp pluripotent stem cells’ (DPPSCs’) osteogenesis and inflammation modulation in human macrophages. All implants successfully osseointegrated, as demonstrated by the results of our clinical and histological studies. The BBL-treated implants showed significantly lower pain scores by day 7 (p < 0.00001) and improved stability by day 30 (ISQ > 62.00 ± 0.59, p < 8 × 10−7). By day 60, CBCT scans revealed an increased bone area ratio in BBL-treated implants. AFM images demonstrated the BBL’s softening and wettability effect on implant surfaces. Furthermore, the BBL promoted DPPSCs’ osteogenesis and modulated inflammatory markers in human primary macrophages. This study presents compelling clinical and biological evidence that BBL treatment improves Galaxy TS implant stability, reduces pain, and enhances bone formation, possibly through surface tension modulation and immunomodulatory effects. This advancement holds promise for enhancing patient outcomes and implant longevity.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Animal and Imaging Core Facilities, Dasman Diabetes Institute, Dasman 15462, Kuwait

Biointelligent Technology Systems SL, C/Diputaccion 316, 3D, 08009 Barcelona, Spain

Periodontology Department, Universitat Internacional de Catalunya (UIC), C/Josep Trueta s/n, 08195 Barcelona, Spain

Oral and Maxillofacial Surgery Department, Universitat Internacional de Catalunya (UIC), St Josep Trueta s/n, 08195 Barcelona, Spain

Oral and Maxillofacial Surgery and Pediatric Dentistry Department, Universitat Internacional de Catalunya (UIC), St Josep Trueta s/n, 08195 Barcelona, Spain

Biochemistry and Molecular Biology Department, Universidad Pública de Navarra, 31006 Pamplona, Spain

Inves Biofarm, Avd. Conocimiento, 34, 18016 Granada, Spain

Oral and Maxillofacial Surgery Department, Hospital Clinic de Barcelona, 08036 Barcelona, Spain

Funding

Public University of Navarra

References (58)

Show source-provided references
1. Comparing the Quality of Life of Patients Requesting Dental Implants Before and After Implant10.2174/1874210601711010485 ↗
2. Traditional Removable Partial Dentures versus Implant-Supported Removable Partial Dentures: A Retrospective, Observational Oral Health-Related Quality-of-Life Study10.3390/prosthesis3040032 ↗
3. Bone manipulation procedures in dental implants10.4103/0975-962X.184650 ↗
4. Implant biomaterials: A comprehensive review10.12998/wjcc.v3.i1.52 ↗
5. Osseointegration: An update10.1007/s13191-013-0252-z ↗
6. Osseointegrated supported prosthesis—Surgical techniques for hard and soft tissue grafting10.4103/0974-6781.131010 ↗
7. Lin, H.K., Pan, Y.H., Salamanca, E., Lin, Y.T., and Chang, W.J. (2019). Prevention of Bone Resorption by HA/β-TCP + Collagen Composite after Tooth Extraction: A Case Series. Int. J. Environ. Res. Public Health, 16.10.3390/ijerph16234616 ↗
8. Alveolar ridge resorption following tooth extraction10.1016/0022-3913(67)90046-7 ↗
9. Functional and Esthetic Indication for Dental Implant Treatment and Immediate Loading (2) Case Report and Considerations: Typical Attitudes of Dentists (and their Unions) toward Tooth Extractions and the Prevention of Early, Effective, and Helpful Dental Implant Treatment in the European Union10.4103/ams.ams_152_19 ↗
10. Revolutionary Concept in Implant Dentistry10.4103/ams.ams_58_19 ↗
11. IL-1β promotes osteoclastogenesis by increasing the expression of IGF2 and chemokines in non-osteoclastic cells10.1016/j.jphs.2022.10.007 ↗
12. TNF-alpha and pathologic bone resorption10.2302/kjm.54.127 ↗
13. Tumor necrosis factors in 1998
14. Xu, J., Yu, L., Liu, F., Wan, L., and Deng, Z. (2023). The effect of cytokines on osteoblasts and osteoclasts in bone remodeling in osteoporosis: A review. Front. Immunol., 14.10.3389/fimmu.2023.1222129 ↗
15. Cytokines in periodontal disease: Where to from here?10.1080/000163501750266765 ↗
16. The clinical significance of implant stability quotient (ISQ) measurements: A literature review10.1016/j.jobcr.2020.07.004 ↗
17. Effect of implant macro-design on primary stability: A prospective clinical study
18. Vollmer, A., Saravi, B., Lang, G., Adolphs, N., Hazard, D., Giers, V., and Stoll, P. (2020). Factors Influencing Primary and Secondary Implant Stability—A Retrospective Cohort Study with 582 Implants in 272 Patients. Appl. Sci., 10.10.3390/app10228084 ↗
19. Krischik, D., Tokgöz, S.E., van Orten, A., Friedmann, A., and Bilhan, H. (2021). An In Vitro Evaluation of Primary Stability Values for Two Differently Designed Implants to Suit Immediate Loading in Very Soft Bone. Dent. J., 9.10.3390/dj9010005 ↗
20. Stability of implants placed in fresh sockets versus healed alveolar sites: Early findings10.1111/clr.12624 ↗
21. Ivanova, V., Chenchev, I., Zlatev, S., and Mijiritsky, E. (2021). Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18136994 ↗
22. Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value10.4047/jap.2011.3.1.10 ↗
23. Evaluation of implant stability and bone loss using two different early loading protocols: Clinical study10.1111/ors.12752 ↗
24. Prostran, M. (2017). Dental Implants in the Medically Compromised Patient Population. Clinical Trials in Vulnerable Populations, IntechOpen.
25. Wychowański, P., Starzyńska, A., Jereczek-Fossa, B.A., Iwanicka-Grzegorek, E., Kosewski, P., Adamska, P., and Woliński, J. (2021). The Effects of Smoking Cigarettes on Immediate Dental Implant Stability—A Prospective Case Series Study. Appl. Sci., 11.10.3390/app11010027 ↗
26. Ferres-Amat, E., Al Madhoun, A., Ferres-Amat, E., Al Demour, S., Ababneh, M.A., Ferres-Padro, E., Marti, C., Carrio, N., Barajas, M., and Atari, M. (2021). Histologic and Histomorphometric Evaluation of a New Bioactive Liquid BBL on Implant Surface: A Preclinical Study in Foxhound Dogs. Materials, 14.10.3390/ma14206217 ↗
27. Ferres-Amat, E., Al Madhoun, A., Ferres-Amat, E., Carrio, N., Barajas, M., Al-Madhoun, A.S., Ferres-Padro, E., Marti, C., and Atari, M. (2022). Comparison of 0.12% Chlorhexidine and a New Bone Bioactive Liquid, BBL, in Mouthwash for Oral Wound Healing: A Randomized, Double Blind Clinical Human Trial. J. Pers. Med., 12.10.20944/preprints202209.0409.v1 ↗
28. Differences between buccal and lingual bone quality and quantity of peri-implant regions10.1016/j.jmbbm.2015.12.036 ↗
29. Hard tissue changes after guided bone regeneration of peri-implant defects comparing block versus particulate bone substitutes: 6-month results of a randomized controlled clinical trial10.1111/clr.13515 ↗
30. Ilastik: Interactive machine learning for (bio)image analysis10.1038/s41592-019-0582-9 ↗
31. Pain assessment. European spine journal: Official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society10.1007/s00586-005-1044-x ↗
32. The enhancement of osteogenesis through the use of dental pulp pluripotent stem cells in 3D10.1016/j.bone.2012.01.005 ↗
33. Improvement of osteogenesis in dental pulp pluripotent-like stem cells by oligopeptide-modified poly(beta-amino ester)s10.1016/j.actbio.2017.01.077 ↗
34. Nunez-Toldra, R., Martinez-Sarra, E., Gil-Recio, C., Carrasco, M.A., Al Madhoun, A., Montori, S., and Atari, M. (2017). Dental pulp pluripotent-like stem cells (DPPSC), a new stem cell population with chromosomal stability and osteogenic capacity for biomaterials evaluation. BMC Cell Biol., 18.10.1186/s12860-017-0137-9 ↗
35. Maher, A., Nunez-Toldra, R., Carrio, N., Ferres-Padro, E., Ali, H., Montori, S., and Al Madhoun, A. (2018). The Effect of Commercially Available Endodontic Cements and Biomaterials on Osteogenic Differentiation of Dental Pulp Pluripotent-Like Stem Cells. Dent. J., 6.10.3390/dj6040048 ↗
36. Sample size considerations for split-mouth design10.1177/0962280215601137 ↗
37. Surface-conditioned dental implants: An animal study on bone formation10.1111/j.1600-051X.2009.01466.x ↗
38. Lopez-Valverde, N., Flores-Fraile, J., Ramirez, J.M., Sousa, B.M., Herrero-Hernandez, S., and Lopez-Valverde, A. (2020). Bioactive Surfaces vs. Conventional Surfaces in Titanium Dental Implants: A Comparative Systematic Review. J. Clin. Med., 9.10.3390/jcm9072047 ↗
39. Enhanced implant stability with a chemically modified SLA surface: A randomized pilot study
40. Lech, A., Butruk-Raszeja, B.A., Ciach, T., Lawniczak-Jablonska, K., Kuzmiuk, P., Bartnik, A., Wachulak, P., and Fiedorowicz, H. (2020). Surface Modification of PLLA, PTFE and PVDF with Extreme Ultraviolet (EUV) to Enhance Cell Adhesion. Int. J. Mol. Sci., 21.10.3390/ijms21249679 ↗
41. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
42. Scarano, A., Inchingolo, F., Murmura, G., Traini, T., Piattelli, A., and Lorusso, F. (2018). Three-Dimensional Architecture and Mechanical Properties of Bovine Bone Mixed with Autologous Platelet Liquid, Blood, or Physiological Water: An In Vitro Study. Int. J. Mol. Sci., 19.10.3390/ijms19041230 ↗
43. Interleukins 1beta and 10 expressions in the periimplant crevicular fluid from patients with untreated periimplant disease10.1097/ID.0b013e3182818792 ↗
44. Differential cytokine expressions affect the severity of peri-implant disease10.1111/j.1600-0501.2008.01680.x ↗
45. Clinical and biologic factors related to oral implant failure: A 2-year follow-up study10.1097/01.id.0000173626.00889.15 ↗
46. Qi, F., Li, H., Chen, G., Peng, S., Luo, X., Xiong, S., Zhu, H., and Shuai, C. (2023). A CuS@g-C3N4 heterojunction endows scaffold with synergetic antibacterial effect. Colloids Surf. B Biointerfaces, 230.10.1016/j.colsurfb.2023.113512 ↗
47. Faot, F., Bielemann, A.M., Schuster, A.J., Marcello-Machado, R.M., Del Bel Cury, A.A., Nascimento, G.G., and Chagas-Junior, O.L. (2019). Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles. Biomed. Res. Int., 2019.10.1155/2019/8132520 ↗
48. Implant insertional torque values predict outcomes10.1016/j.joms.2010.11.008 ↗
49. Implant micromotion is related to peak insertion torque and bone density10.1111/j.1600-0501.2008.01679.x ↗
50. Validation of value of actual micromotion as a direct measure of implant micromobility after healing (secondary implant stability). An in vivo histologic and biomechanical study10.1111/clr.12756 ↗
51. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
52. Split-mouth designs in orthodontics: An overview with applications to orthodontic clinical trials10.1093/ejo/cjs108 ↗
53. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement10.1007/s00784-005-0031-2 ↗
54. Radiographic detection and assessment of the periodontal endosseous defects10.1034/j.1600-051x.2000.027004224.x ↗
55. Computer-assisted simulations in orthodontic diagnosis and the application of a new cone beam X-ray computed tomography10.1034/j.1600-0544.2003.241.x ↗
56. Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views10.1111/clr.13019 ↗
57. CBCT-based bone quality assessment: Are Hounsfield units applicable?10.1259/dmfr.20140238 ↗
58. Cone beam computed tomography in implant dentistry: A systematic review focusing on guidelines, indications, and radiation dose risks10.11607/jomi.2014suppl.g1.4 ↗