Dental Implant Abutment Screw Loss: Presentation of 10 Cases
Source abstract
Abstract
Re-tightening the loosened dental implant abutment screw is an accepted procedure, however the evidence that such screw will hold sufficiently is weak. The purpose of this study was material analysis of lost dental implant abutment screws made of the TiAlV alloy from various manufacturers, which became lost due to unscrewing or damaged when checking if unscrewed; undamaged screws could be safely re-tightened. Among 13 failed screws retrieved from 10 cases, 10 screws were removed due to untightening and 3 were broken but without mechanical damage at the threads. Advanced corrosion was found on nine screws after 2 years of working time on all surfaces, also not mechanically loaded. Sediments observed especially in the thread area did not affect the corrosion process because of no pit densification around sediments. Pitting corrosion visible in all long-used screws raises the question of whether the screws should be replaced after a certain period during service, even if they are well-tightened. This requires further research on the influence of the degree of corrosion on the loss of the load-bearing ability of the screw.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, 18a Konarskiego Str., 41-100 Gliwice, Poland
Doctoral School, Silesian University of Technology, 2A Akademicka Str., 44-100 Gliwice, Poland
Anident Dental Clinic, 12 Belgradzka Str., 02-793 Warszawa, Poland
References (28)
Show source-provided references
1. Clinical Study on Screw Loosening in Dental Implant Prostheses: A 6-Year Retrospective Study10.5125/jkaoms.2020.46.2.133 ↗
2. Abutment Screw Loosening in Implants: A Literature Review10.4103/jfmpc.jfmpc_1343_20 ↗
3. Influence of Implant-Abutment Contact Surfaces and Prosthetic Screw Tightening on the Stress Concentration, Fatigue Life and Microgap Formation: A Finite Element Analysis10.3390/oral1020009 ↗
4. Epifania, E., di Lauro, A.E., Ausiello, P., Mancone, A., Garcia-Godoy, F., and Tribst, J.P.M. (2023). Effect of Crown Stiffness and Prosthetic Screw Absence on the Stress Distribution in Implant-Supported Restoration: A 3D Finite Element Analysis. PLoS ONE, 18.10.1371/journal.pone.0285421 ↗
5. Effects of Tightening Torque on Screw Stress and Formation of Implant-Abutment Microgaps: A Finite Element Analysis10.1016/j.prosdent.2020.11.026 ↗
6. Impact of Tribocorrosion and Titanium Particles Release on Dental Implant Complications—A Narrative Review10.1016/j.jdsr.2021.09.001 ↗
7. Souza, J.C.M., Henriques, M., Teughels, W., Ponthiaux, P., Celis, J.P., and Rocha, L.A. (2015). Wear and Corrosion Interactions on Titanium in Oral Environment: Literature Review. J. Bio-Tribo-Corros., 1.10.1007/s40735-015-0013-0 ↗
8. Fretting-Corrosion Behavior on Dental Implant Connection in Human Saliva10.1016/j.jmbbm.2019.02.025 ↗
9. Causes of Degradation of Titanium Dental Implants10.23939/ujmems2022.04.031 ↗
10. Degradation Mechanisms and Future Challenges of Titanium and Its Alloys for Dental Implant Applications in Oral Environment10.1016/j.msec.2017.02.159 ↗
11. Evaluation the Loosening of Abutment Screws in Fluid Contamination: An in Vitro Study10.1038/s41598-022-14791-w ↗
12. Effects of Two Fretting Damage Modes on the Dental Implant–Abutment Interface and the Generation of Metal Wear Debris: An in Vitro Study10.1111/ffe.13399 ↗
13. In Vivo Severe Corrosion and Hydrogen Embrittlement of Retrieved Modular Body Titanium Alloy Hip-Implants10.1002/jbm.b.31171 ↗
14. Biofilm Formation on Surface Characterized Micro-Implants for Skeletal Anchorage in Orthodontics10.1016/j.biomaterials.2006.12.014 ↗
15. Ossowska, A., and Zieliński, A. (2020). The Mechanisms of Degradation of Titanium Dental Implants. Coatings, 10.10.3390/coatings10090836 ↗
16. Corrosion of Titanium under Simulated Inflammation Conditions: Clinical Context and in Vitro Investigations10.1016/j.actbio.2021.10.002 ↗
17. Effect of Different Angulations and Collar Lengths of Conical Hybrid Implant Abutment on Screw Loosening after Dynamic Cyclic Loading10.1186/s40729-018-0149-z ↗
18. Differences in Micromorphology of the Implant-Abutment Junction for Original and Third-Party Abutments on a Representative Dental Implant10.1016/j.prosdent.2018.02.015 ↗
19. The Effect of Different Implant-Abutment Connections on Screw Joint Stability10.1563/AAID-JOI-D-11-00032 ↗
20. In Vitro Analysis of Post-Fatigue Reverse-Torque Values at the Dental Abutment/Implant Interface for a Unitarian Abutment Design10.1111/j.1532-849X.2011.00756.x ↗
21. Influence of the Implant Abutment Types and the Dynamic Loading on Initial Screw Loosening10.4047/jap.2013.5.1.21 ↗
22. Torque Removal Evaluation of One-Piece and Two-Piece Abutment Screws under Dry and Wet Conditions
23. Micromovement Evaluation of Original and Compatible Abutments at the Implant-Abutment Interface10.5005/jp-journals-10024-1952 ↗
24. Screw Loosening of Original and Non-Original Abutments in Implant Dentistry: An in Vitro Study
25. Evaluation of the Mechanical Behavior and Marginal Accuracy of Stock and Laser-Sintered Implant Abutments10.11607/ijp.5089 ↗
26. Accuracy Combining Different Brands of Implants and Abutments
27. Radiographic Verification of Implant Abutment Seating10.1016/S0022-3913(98)70241-0 ↗
28. Detection of Misfits at the Abutment-Prosthesis Interface in the Esthetic Zone: Implications of the Radiographic Technique and the Magnitude of the Misfit10.1016/j.prosdent.2023.05.026 ↗