Fibronectin Conformations after Electrodeposition onto 316L Stainless Steel Substrates Enhanced Early-Stage Osteoblasts’ Adhesion but Affected Their Behavior
Source abstract
Abstract
The implantation of metallic orthopedic prostheses is increasingly common due to an aging population and accidents. There is a real societal need to implement new metal implants that combine durability, good mechanical properties, excellent biocompatibility, as well as affordable costs. Since the functionalization of low-cost 316L stainless steel substrates through the successive electrodeposition of a polypyrrole film (PPy) and a calcium phosphate deposit doped with silicon was previously carried out by our labs, we have also developed a bio-functional coating by electrodepositing or oxidating of fibronectin (Fn) coating. Fn is an extracellular matrix glycoprotein involved in cell adhesion and differentiation. Impacts of either electrodeposition or oxidation on the structure and functionality of Fn were first studied. Thus, electrodeposition is the technique that permits the highest deposition of fibronectin, compared to adsorption or oxidation. Furthermore, electrodeposition seems to strongly modify Fn conformation by the formation of intermingled long fibers, resulting in changes to the accessibility of the molecular probes tested (antibodies directed against Fn whole molecule and Fn cell-binding domain). Then, the effects of either electrodeposited Fn or oxidized Fn were validated by the resulting pre-osteoblast behavior. Electrodeposition reduced pre-osteoblasts’ ability to remodel Fn coating on supports because of a partial modification of Fn conformation, which reduced accessibility to the cell-binding domain. Electrodeposited Fn also diminished α5 integrin secretion and clustering along the plasma membrane. However, the N-terminal extremity of Fn was not modified by electrodeposition as demonstrated by Staphylococcus aureus attachment after 3 h of culture on a specific domain localized in this region. Moreover, the number of pre-osteoblasts remains stable after 3 h culture on either adsorbed, oxidized, or electrodeposited Fn deposits. In contrast, mitochondrial activity and cell proliferation were significantly higher on adsorbed Fn compared with electrodeposited Fn after 48 h culture. Hence, electro-deposited Fn seems more favorable to pre-osteoblast early-stage behavior than during a longer culture of 24 h and 48 h. The electrodeposition of matrix proteins could be improved to maintain their bio-activity and to develop this promising, fast technique to bio-functionalize metallic implants.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Polymer Surface Interaction Studies · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratoire de Physicochimie des Polymères et des Interfaces (LPPI Lab), CY Cergy Paris University, F-95000 Cergy, France
Equipe de Recherche sur les Relations Matrice Extracellulaire-Cellule (ERRMECe Lab), CY Cergy Paris University, F-95000 Cergy, France
Funding
CY I-Mat Foundation
References (57)
Show source-provided references
1. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
2. Chandra, G. (2014). Bio-Implants Market—Global Opportunity Analysis and Industry Forecast, 2013–2020, Allied Market Research.
3. Nikolova, M.P., and Apostolova, M.D. (2022). Advances in Multifunctional Bioactive Coatings for Metallic Bone Implants. Materials, 16.10.3390/ma16010183 ↗
4. Biomaterial strategies for engineering implants for enhanced osseointegration and bone repair10.1016/j.addr.2015.03.013 ↗
5. Metal release rate from AISI 316L stainless steel and pure Fe, Cr and Ni into a synthetic biological medium—A comparison10.1039/b805075a ↗
6. Electropolymerization and Possible Corrosion Protection Effect of Polypyrrole Coatings on AA1050 (UNS A91050) in NaCl Solutions10.5006/3124 ↗
7. A comprehensive review on metallic implant biomaterials and their subtractive manufacturing10.1007/s00170-022-08770-8 ↗
8. Titanium: A review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity10.1111/cod.12565 ↗
9. Lamret, F., Colin, M., Mongaret, C., Gangloff, S.C., and Reffuveille, F. (2020). Antibiotic Tolerance of. Antibiotics, 9.10.3390/antibiotics9090547 ↗
10. Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings10.1002/jbm.b.33115 ↗
11. Chang, S.-H., and Hsiao, Y.-C. (2017). Surface and Protein Adsorption Properties of 316L Stainless Steel Modified with Polycaprolactone Film. Polymers, 9.10.3390/polym9100545 ↗
12. Nanosecond laser fabrication of superhydrophobic surface on 316L stainless steel and corrosion protection application10.1016/j.colsurfa.2020.125259 ↗
13. A new double-layer sol-gel coating to improve the corrosion resistance of a medical-grade stainless steel in a simulated body fluid10.1016/j.matlet.2013.01.111 ↗
14. Biosensitive and antibacterial coatings on metallic material for medical applications10.1002/cbin.11604 ↗
15. Studies on the formation process and anti-corrosion performance of polypyrrole film deposited on the surface of Q235 steel by an electrochemical method10.1016/j.surfcoat.2017.12.034 ↗
16. Nanocomposites of conductive polymers and nanoparticles deposited on porous material as a strategy to improve its corrosion resistance10.1016/j.surfcoat.2020.126395 ↗
17. Electrodeposition and characterization of polypyrrole films on aluminium alloy 6061-T610.1016/j.electacta.2008.01.059 ↗
18. Corrosion protection performance of porous strontium hydroxyapatite coating on polypyrrole coated 316L stainless steel10.1016/j.colsurfb.2013.01.065 ↗
19. Electrodeposition of polypyrrole on 316L stainless steel for corrosion prevention10.1016/j.corsci.2010.09.021 ↗
20. Some biocompatibility aspects of conducting polymer polypyrrole evaluated with bone marrow-derived stem cells10.1016/j.colsurfa.2013.06.030 ↗
21. Conductive polymers: Towards a smart biomaterial for tissue engineering10.1016/j.actbio.2014.02.015 ↗
22. Polypyrrole-Incorporated Conducting Constructs for Tissue Engineering Applications: A Review10.1089/bioe.2020.0010 ↗
23. Development and relative comparison of polypyrrole-calcium phosphate composite coatings with differential concentration of chlorophyll functionalized polymer particle achieved through pulsed electro deposition10.1016/j.surfcoat.2019.02.025 ↗
24. Maimaiti, B., Zhang, N., Yan, L., Luo, J., Xie, C., Wang, Y., Ma, C., and Ye, T. (2019). Stable ZnO-doped hydroxyapatite nanocoating for anti-infection and osteogenic on titanium. Colloids Surf. B Biointerfaces, 186.10.1016/j.colsurfb.2019.110731 ↗
25. Landim, V.P.A., Foguel, M.V., Prado, C.M., Sotomayor, M.P.T., Vieira, I.C., Silva, B.V.M., and Dutra, R.F. (2022). A Polypyrrole/Nanoclay Hybrid Film for Ultra-Sensitive Cardiac Troponin T Electrochemical Immunosensor. Biosensors, 12.10.3390/bios12070545 ↗
26. Hydrophobic conducting polymer films from post deposition thiol exposure10.1016/j.synthmet.2012.06.013 ↗
27. Synthesis, analytical characterization, and osteoblast adhesion properties on RGD-grafted polypyrrole coatings on titanium substrates10.1163/156856200743580 ↗
28. Mono vs. multilayer fibronectin coatings on polar/hydrophobic/ionic polyurethanes: Altering surface interactions with human monocytes10.1016/j.actbio.2017.11.013 ↗
29. Wettability of substrata controls cell-substrate and cell-cell adhesions10.1016/j.bbagen.2007.07.008 ↗
30. Surface oxide net charge of a titanium alloy: Modulation of fibronectin-activated attachment and spreading of osteogenic cells10.1016/j.colsurfb.2010.08.023 ↗
31. Tissue engineering strategies for the regeneration of orthopedic interfaces10.1007/s10439-010-0046-y ↗
32. Ishihara, K., Mitera, K., Inoue, Y., and Fukazawa, K. (2020). Effects of molecular interactions at various polymer brush surfaces on fibronectin adsorption induced cell adhesion. Colloids Surf. B Biointerfaces, 194.10.1016/j.colsurfb.2020.111205 ↗
33. The effect of extracellular matrix proteins on the cellular response of HUVECS and HOBS after covalent immobilization onto titanium10.1002/jbm.a.35340 ↗
34. Control of osteoblast cells adhesion and spreading by microcontact printing of extracellular matrix protein patterns10.1016/j.colsurfb.2012.11.045 ↗
35. Inhibition of Escherichia coli and Proteus mirabilis adhesion and biofilm formation on medical grade silicone surface10.1002/bit.23342 ↗
36. He, Y., Dai, L.F., Zhang, X.M., Sun, Y.N., Shi, W., and Ge, D.T. (2020). The Bioactive Polypyrrole/Polydopamine Nanowire Coating with Enhanced Osteogenic Differentiation Ability with Electrical Stimulation. Coatings, 10.10.3390/coatings10121189 ↗
37. An efficient and inexpensive method for functionalizing metallic biomaterials used in orthopedic applications10.1016/j.colcom.2020.100282 ↗
38. Enhanced expression of the osteoblastic phenotype on substrates that modulate fibronectin conformation and integrin receptor binding10.1016/S0142-9612(01)00387-8 ↗
39. Modulation of cell adhesion, proliferation and differentiation on materials designed for body implants10.1016/j.biotechadv.2011.06.004 ↗
40. Electrodeposition of pronectin for titanium to augment gingival epithelium adhesion10.1002/term.527 ↗
41. Electrophoretic deposition of polymers and proteins for biomedical applications10.1016/j.cis.2020.102272 ↗
42. Wong, J.Y., Langer, R., and Ingber, D.E. (December, January 29). Cell-interactions with fibronectin-coated electrically conducting polypyrrole thin-films. Proceedings of the Symposium on Biomaterials for Drug and Cell Delivery, Boston, MA, USA.
43. Effects of Fibronectin Coating on Bacterial and Osteoblast Progenitor Cells Adherence in a Co-culture Assay10.1007/5584_2016_41 ↗
44. Toffoli, A., Parisi, L., Bianchi, M.G., Lumetti, S., Bussolati, O., and Macaluso, G.M. (2020). Thermal treatment to increase titanium wettability induces selective proteins adsorption from blood serum thus affecting osteoblasts adhesion. Mater. Sci. Eng. C Mater. Biol. Appl., 107.10.1016/j.msec.2019.110250 ↗
45. Amyloid-like aggregates formation by blood plasma fibronectin10.1016/j.ijbiomac.2017.01.061 ↗
46. Dynamic structure of plasma fibronectin10.1080/10409238.2016.1184224 ↗
47. Fibronectin amyloid-like aggregation alters its extracellular matrix incorporation and promotes a single and sparsed cell migration10.1016/j.yexcr.2018.07.047 ↗
48. Hindié, M., Camand, E., Agniel, R., Carreiras, F., Pauthe, E., and Van Tassel, P. (2014). Effects of human fibronectin and human serum albumin sequential adsorption on preosteoblastic cell adhesion. Biointerphases, 9.10.1116/1.4867598 ↗
49. Integrins: Bidirectional, allosteric signaling machines10.1016/S0092-8674(02)00971-6 ↗
50. Fibronectin and its soluble EDA-FN isoform as biomarkers for inflammation and sepsis10.17219/acem/104531 ↗
51. Recent advances of polypyrrole conducting polymer film for biomedical application: Toward a viable platform for cell-microbial interactions10.1016/j.cis.2023.102860 ↗
52. Surface electric properties of polypyrrole in aqueous solutions10.1021/la034893v ↗
53. Diversity of bone matrix adhesion proteins modulates osteoblast attachment and organization of actin cytoskeleton10.1016/j.morpho.2014.02.003 ↗
54. Fibronectin modulates osteoblast behavior on Nitinol10.1002/jbm.a.31953 ↗
55. Dalton, C.J., and Lemmon, C.A. (2021). Fibronectin: Molecular Structure, Fibrillar Structure and Mechanochemical Signaling. Cells, 10.10.20944/preprints202108.0010.v1 ↗
56. Sevilla, C.A., Dalecki, D., and Hocking, D.C. (2013). Regional fibronectin and collagen fibril co-assembly directs cell proliferation and microtissue morphology. PLoS ONE, 8.10.1371/journal.pone.0077316 ↗
57. An altered fibronectin matrix induces anoikis of human squamous cell carcinoma cells by suppressing integrin alpha v levels and phosphorylation of FAK and ERK10.1007/s10495-007-0138-9 ↗