Replicate bones are widely used as an alternative for cadaveric bones for in vitro testing. These composite bone models are more easily available and show low inter-specimen variability compared to cadaveric bone models. The combination of in vitro testing with in silico models can provide further insights in the evaluation of the mechanical behavior of orthopedic implants. An accurate numerical representation of the experimental model is important to draw meaningful conclusions from the numerical predictions. This study aims to determine the elastic material constants of a commonly used composite clavicle model by combining acoustic experimental and numerical modal analysis. The difference between the experimental and finite element (FE) predicted natural frequencies was minimized by updating the elastic material constants of the transversely isotropic cortical bone analogue that are provided by the manufacturer. The longitudinal Young’s modulus was reduced from 16.00 GPa to 12.88 GPa and the shear modulus was increased from 3.30 GPa to 4.53 GPa. These updated material properties resulted in an average natural frequency difference of 0.49% and a maximum difference of 1.73% between the FE predictions and the experimental results. The presented updated model aims to improve future research that focuses on mechanical simulations with clavicle composite bone models.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Shoulder and Clavicle Injuries · Rock Mechanics and Modeling · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium
Division of Orthopaedics, University Hospital Leuven, 3000 Leuven, Belgium
Department of Mechanical Engineering, MSD Section, KU Leuven, 3000 Leuven, Belgium
Funding
KU Leuven
References (54)
Show source-provided references
1. Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation10.1007/s00264-012-1671-x ↗
2. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out10.1016/j.jmbbm.2017.10.016 ↗
3. Reconstruction plates for stabilization of mid-shaft clavicle fractures: Differences between nonlocked and locked plates in two different positions10.1016/j.jse.2008.10.002 ↗
4. Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses
5. Biomechanical comparison of three different plate configurations for comminuted clavicle midshaft fracture fixation10.1016/j.jse.2017.06.034 ↗
6. Vancleef, S., Vanhove, H., Herteleer, M., Stefaan, N., Joost, D., and Jos, V.S. (2017, January 2–5). Case-study: Assessment of a patient-specific and commercial plate for clavicle fracture fixation. Proceedings of the Congress of the European Society of Biomechanics, Sevilla, Spain.
7. Determination of replicate composite bone material properties using modal analysis10.1016/j.jmbbm.2016.10.018 ↗
8. Mechanical validation of whole bone composite tibia models10.1016/S0021-9290(99)00186-4 ↗
9. Mechanical characterization of fourth generation composite humerus10.1177/0954411911423346 ↗
10. Strength analysis of clavicle fracture fixation devices and fixation techniques using finite element analysis with musculoskeletal force input10.1007/s11517-015-1288-5 ↗
11. Superior versus Anteroinferior Plating of the Clavicle: A Finite Element Study10.1097/BOT.0b013e3182143e06 ↗
12. Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture10.1016/j.medengphy.2016.06.021 ↗
13. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures10.1016/j.injury.2016.06.004 ↗
14. A finite element parametric study of clavicle fixation plates10.1002/cnm.2710 ↗
15. Finite Element Modeling of Human Clavicle under Dynamic Loading
16. Zeng, L., Wei, H., Liu, Y., Zhang, W., Pan, Y., Zhang, W., Zhang, C., Zeng, B., and Chen, Y. (2015). Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study. PLoS ONE, 10.10.1371/journal.pone.0126131 ↗
17. Extracting clinically relevant data from finite element simulations10.1016/j.clinbiomech.2005.01.010 ↗
18. Validation of finite element models for strain analysis of implant-supported prostheses using digital image correlation10.1016/j.dental.2013.04.010 ↗
19. Experimental Validation of Finite Element Models of Intact and Implanted Composite Hemipelvises Using Digital Image Correlation10.1115/1.4007173 ↗
20. Experimental Validation of a Finite Element Model of the Proximal Femur Using Digital Image Correlation and a Composite Bone Model10.1115/1.4003129 ↗
21. Experimental validation of finite element model for proximal composite femur using optical measurements10.1016/j.jmbbm.2013.02.006 ↗
22. Experimental Validation of a Finite Element Model of a Human Cadaveric Tibia10.1115/1.2913335 ↗
23. Development and validation of a subject-specific finite element model of a human clavicle10.1080/10255842.2011.641122 ↗
24. The sensitivity method in finite element model updating: A tutorial10.1016/j.ymssp.2010.10.012 ↗
25. Determination of orthotropic bone elastic constants using FEA and modal analysis10.1016/S0021-9290(02)00022-2 ↗
26. Heylen, W., and Sas, P. (2006). Modal Analysis Theory and Testing, Departement Werktuigkunde, Katholieke Universiteit Leuven.
27. Accurate measurement of cortical bone elasticity tensor with resonant ultrasound spectroscopy10.1016/j.jmbbm.2012.09.017 ↗
28. Assessment of elastic coefficients of child cortical bone using resonant ultrasound spectroscopy10.1016/j.jmbbm.2018.09.044 ↗
29. Finite element modelling of the vibrational behaviour of the human femur using CT-based individualized geometrical and material properties10.1016/S0021-9290(98)00018-9 ↗
30. Development of a three-dimensional finite element model of a human tibia using experimental modal analysis10.1016/0021-9290(91)90026-J ↗
31. Experimental modal analysis on fresh-frozen human hemipelvic bones employing a 3D laser vibrometer for the purpose of modal parameter identification10.1016/j.jbiomech.2011.03.005 ↗
32. Validation of density–elasticity relationships for finite element modeling of human pelvic bone by modal analysis10.1016/j.jbiomech.2013.07.045 ↗
33. (2020, September 23). Sawbones Biomechanical Catalog. Available online: http://www.sawbones.com/UserFiles/Docs/biomechanical_catalog.pdf.
34. Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study10.1016/j.medengphy.2017.08.007 ↗
35. Prediction of strength and strain of the proximal femur by a CT-based finite element method10.1016/j.jbiomech.2006.08.003 ↗
36. Sensitivity-based finite element model updating of a pontoon bridge10.1016/j.engstruct.2017.07.025 ↗
37. Characterization of bone-implant fixation using modal analysis: Application to a press-fit implant model10.1016/j.jbiomech.2009.04.030 ↗
38. Vibrational Characteristics of Bone Fracture and Fracture Repair: Application to Excised Rat Femur10.1115/1.2187037 ↗
39. Study of the vibrational behaviour of a healing tibia using finite element modelling10.1016/0021-9290(96)00002-4 ↗
40. Ethanol and formaldehyde fixation irreversibly alter bones’ organic matrix10.1016/j.jmbbm.2013.09.008 ↗
41. Relationship between the shape and density distribution of the femur and its natural frequencies of vibration10.1016/j.jbiomech.2014.08.008 ↗
42. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study10.1016/j.medengphy.2017.07.006 ↗
43. A finite element analysis of the vibrational behaviour of the intra-operatively manufactured prosthesis–femur system10.1016/j.medengphy.2008.11.017 ↗
44. Evaluation of acetabular cup initial fixation by using resonance frequency principle10.1177/0954411914561485 ↗
45. Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study10.1121/1.4941452 ↗
46. Combined finite element and multibody musculoskeletal investigation of a fractured clavicle with reconstruction plate10.1080/10255842.2013.845175 ↗
47. Influence of geometrical personalization on the simulation of clavicle fractures10.1016/j.jbiomech.2007.06.020 ↗
48. Experimental validation of a finite element model of a composite tibia10.1243/09544119JEIM119 ↗
49. Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses10.1016/j.medengphy.2007.12.009 ↗
50. Micromechanics-Based Conversion of CT Data into Anisotropic Elasticity Tensors, Applied to FE Simulations of a Mandible10.1007/s10439-007-9393-8 ↗
51. Gilroy, D., Young, A.M., Phillips, A., Wheel, M., and Riches, P.E. (2014, January 6–11). Characterization and Validation of Sawbones Artificial Composite Femur material. Proceedings of the 7th World Congress of Biomechanics, Boston, MA, USA.
52. (2009). Appendix A: Mechanical Properties. Mechanics of Optimal Structural Design, John Wiley & Sons, Ltd.
53. Structural Properties of a Novel Design of Composite Analogue Humeri Models10.1007/s10439-008-9568-y ↗
54. Structural properties of fourth-generation composite femurs and tibias10.1016/j.jbiomech.2008.08.013 ↗