Study of an Additional Layer of Cement Mantle Hip Joints for Reducing Cracks
Source abstract
Abstract
Failure of the cement mantle in total hip arthroplasty is not a simple phenomenon. Cracking, which can be caused by crack initiation and repeated loading, can cause loosening of the acetabular liner component. A previous study showed that addition of a metal layer between the liner and acetabular could reduce the stress at the contact surface of the cement mantle. This study elaborates on the performance of the additional layer. Several material properties of the layer were simulated using finite element analysis for maximum performance. A static contact analysis was used to simulate the stresses at the contact surface of the cement mantle. The results show that an additional layer of cobalt chrome produced the best performance.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Engineering Faculty, Diponegoro University, Jl. Prof. Soedarto SH Tembalang, Semarang 50275, Indonesia
Laboratory for Surface Technology and Tribology, Engineering Technology Faculty, Twente University, Postbox 217, 7500 AE Enschede, The Netherlands
Orthopaedic and Traumatology Department, Prof. dr. R. Soeharso Orthopaedic Hospital, Jl. A. Yani Pabelan, Surakarta 57162, Indonesia
Funding
Directorate of Research and Community Service of Ministry of Research, Technology and Higher Education
References (28)
Show source-provided references
1. Cement-mantle thickness affects cement strains in total hip replacement10.1016/S0021-9290(97)00082-1 ↗
2. Jacobs, C.R., Bechtel, J.B., Davis, B.R., Naidu, S.H., and Pellegrini, V.D. (2019, May 02). Fatigue Lifetime Studies of a New Bone Cement Formulation. Available online: https://usermanual.wiki/Document/97504900700FatigueLifetimeStudiesofa NewBoneCementFormulation.878194870.pdf.
3. Letters, T.J., Higgs, R.J.E.D., and Baillie, C.A. (2000, January 12–15). Factors influencing the fatigue life of acrylic bone cements in arthroplasty: An experimental, ex-vivo and finite element analysis. Proceedings of the 46th Annual Meeting, Orthopaedic Research Society, Orlando, FL, USA.
4. Fatigue failure in the cement mantle of a simplified acetabular replacement model10.1016/j.ijfatigue.2006.10.013 ↗
5. (2019). National Ortophaedic Hospital Solo. Internal Report.
6. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses10.1016/j.jbiomech.2009.06.037 ↗
7. Total hip replacement: Tensile stress in bone cement is influenced by cement mantle thickness, acetabular size, bone quality, and body mass index
8. Mann, K., and Hertzler, J. (2001, January 25–28). Crack growth rate in cemented total hip replacement does not depend on cement mantle thickness. Proceedings of the 47th Annual Meeting, Orthopaedic Research Society, San Francisco, CA, USA.
9. Fatigue crack growth rate does not depend on mantle thickness: An idealized cemented stem construct under torsional loading10.1016/S0736-0266(02)00004-9 ↗
10. The Effect of Additional Layer between Liner and PMMA on Reducing Cracks of Cement Mantle Hip Joints
11. Finite element analysis of artificial hip joint movement during human activities10.1016/j.proeng.2013.12.154 ↗
12. The effect of repeated impingement on UHMWPE material in artificial hip joint during salat activities10.4028/www.scientific.net/AMR.896.272 ↗
13. Numerical simulation of artificial hip joint movement for Western and Japanese-style activities
14. (2012). ABAQUS 6.12 Documentation, Dassault Systèmes Simulia Corp.
15. Effect of cement fill ratio in loosening of hip implants10.4161/biom.20709 ↗
16. A subject-specific finite element model of the pelvis: Development, validation and sensitivity studies10.1115/1.1894148 ↗
17. 3D crack behavior in the orthopedic cement mantle of a total hip replacement10.1155/2014/328109 ↗
18. Fracture behavior of the cement mantle of reconstructed acetabulum in the presence of a microcrack emanating from a microvoid
19. Finite element analysis of interfacial crack behaviour in cemented total hip arthroplasty10.1016/j.commatsci.2009.10.007 ↗
20. Mechanical properties of ultra-high molecular weight polyethylene NIST reference material RM 8456
21. Fretting fatigue properties of plasma nitrided AISI 316L stainless steel: Experiments and finite element analysis10.1016/j.triboint.2011.08.011 ↗
22. Biomaterials in orthopaedics10.1098/rsif.2008.0151 ↗
23. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
24. Hip contact forces and gait patterns from routine activities10.1016/S0021-9290(01)00040-9 ↗
25. Research on interface bonding energy of multi-layer on ZChSnSb/FeSn2/Steel10.1016/j.triboint.2018.02.042 ↗
26. Interface bonding properties of multi-layered metal composites using material composition method10.1016/j.triboint.2018.10.024 ↗
27. The tribology of explanted hip resurfacings following early fracture of the femur10.3390/jfb6041021 ↗
28. Orthopaedic metals and their potential toxicity in the arthroplasty patient: A review of current knowledge and future strategies10.1302/0301-620X.89B5.18903 ↗