journal article·2023-05-09Open access

Collarless Polished Tapered Stems of Identical Shape Provide Differing Outcomes for Stainless Steel and Cobalt Chrome: A Biomechanical Study

Ayumi Kaneuji, Mingliang Chen, Eiji Takahashi, Noriyuki Takano, Makoto Fukui, Daisuke Soma, Yoshiyuki Tachi, Yugo Orita, Toru Ichiseki, Norio Kawahara

Abstract

Cemented polished tapered femoral stems (PTS) made of cobalt–chrome alloy (CoCr) are a known risk factor for periprosthetic fracture (PPF). The mechanical differences between CoCr-PTS and stainless-steel (SUS) PTS were investigated. CoCr stems having the same shape and surface roughness as the SUS Exeter® stem were manufactured and dynamic loading tests were performed on three each. Stem subsidence and the compressive force at the bone–cement interface were recorded. Tantalum balls were injected into the cement, and their movement was tracked to indicate cement movement. Stem motions in the cement were greater for the CoCr stems than for the SUS stems. In addition, although we found a significant positive correlation between stem subsidence and compressive force in all stems, CoCr stems generated a compressive force over three times higher than SUS stems at the bone–cement interface with the same stem subsidence (p < 0.01). The final stem subsidence amount and final force were greater in the CoCr group (p < 0.01), and the ratio of tantalum ball vertical distance to stem subsidence was significantly smaller for CoCr than for SUS (p < 0.01). CoCr stems appear to move more easily in cement than SUS stems, which might contribute to the increased occurrence of PPF with the use of CoCr-PTS.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopaedic Surgery, Kanazawa Medical University, Kahoku-gun 920-0293, Japan

Department of Orthopaedics, Affiliated Renhe Hospital of China Three Gorges University, Yichang 443000, China

Department of Mechanical Engineering, Kanazawa Institution of Technology, Nonoichi 921-8501, Japan

Funding

Zimmer Biomet Co.

References (25)

Show source-provided references
1. Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry10.2106/00004623-200204000-00012 ↗
2. A Rough Surface Finish Adversely Affects the Survivorship of a Cemented Femoral Stem
3. Minimum 10-year survival of Kerboull cemented stems according to surface finish10.1007/s11999-007-0074-6 ↗
4. Loosening of matt and polished cemented femoral stems10.1302/0301-620X.80B4.0800573 ↗
5. Periprosthetic femoral fractures and trying to avoid them what is the contribution of femoral component design to the increased risk of periprosthetic femoral fracture?10.1302/0301-620X.99B1.BJJ-2016-0220.R1 ↗
6. Medium to long term follow up of a consecutive series of 604 Exeter Trauma Stem Hemiarthroplasties (ETS) for the treatment of displaced intracapsular femoral neck fractures10.1016/j.injury.2015.10.077 ↗
7. Increased risk for postoperative periprosthetic fracture in hip fracture patients with the Exeter stem than the anatomic SP2 Lubinus stem10.1007/s00068-019-01263-6 ↗
8. Polished, Collarless, Tapered, Cemented Stems for Primary Hip Arthroplasty May Exhibit High Rate of Periprosthetic Fracture at Short-Term Follow-Up10.1016/j.arth.2017.11.003 ↗
9. The influence of cemented femoral stem choice on the incidence of revision for periprosthetic fracture after primary total hip arthroplasty: An analysis of national joint registry data10.1302/0301-620X.98B10.36534 ↗
10. Risk Factors for Revision of Polished Taper-Slip Cemented Stems for Periprosthetic Femoral Fracture After Primary Total Hip Replacement: A Registry-Based Cohort Study from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man10.2106/JBJS.19.01242 ↗
11. Differences in mechanical behavior between Cobalt-chrome alloy and Stainless-steel alloy in polished tapered femoral stems fixed with bone cement
12. Long-Term Survival of the Cemented Exeter Universal Stem in Patients 50 Years and Younger: An Update on 130 Hips10.1016/j.arth.2019.11.009 ↗
13. (2023, March 20). (In Japanese).
14. Stem subsidence of polished and rough double-taper stems: In vitro mechanical effects on the cement-bone interface10.3109/17453670902967265 ↗
15. The influence of cement thickness on stem subsidence and cement creep in a collarless polished tapered stem: When are thick cement mantles detrimental?10.1302/2046-3758.65.BJR-2017-0028.R1 ↗
16. Biomechanical behaviour of a French femoral component with thin cement mantle: The “French paradox” may not be a paradox after all10.1302/2046-3758.77.BJR-2017-0288.R2 ↗
17. Factors affecting the mechanical and viscoelastic properties of acrylic bone cement10.1023/A:1016150403665 ↗
18. Hip joint loading during walking and running, measured in two patients10.1016/0021-9290(93)90058-M ↗
19. Comparison of periprosthetic femoral fracture torque and strain pattern of three types of femoral components in experimental model10.1302/2046-3758.115.BJR-2021-0375.R2 ↗
20. Hirata, M., Oe, K., Kaneuji, A., Uozu, R., Shintani, K., and Saito, T. (2021). Relationship between the surface roughness of material and bone cement: An increased “polished” stem may result in the excessive taper-slip. Materials, 14.10.3390/ma14133702 ↗
21. A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacement10.1016/j.injury.2011.01.008 ↗
22. Periprosthetic fracture torque for short versus standard cemented hip stems: An experimental in vitro study10.1016/j.arth.2013.10.016 ↗
23. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem10.3109/17453674.2014.971388 ↗
24. Temporal Subsidence Patterns of Cemented Polished Taper-Slip Stems: A Systematic Review10.1302/2058-5241.6.200086 ↗
25. Undersizing the Exeter stem in hip hemiarthroplasty increases the risk of periprosthetic fracture10.1177/1120700019855313 ↗