Cement augmentation of pedicle screws is one of the most promising approaches to enhance the anchoring of screws in the osteoporotic spine. To date, there is no ideal cement for pedicle screw augmentation. The purpose of this study was to investigate whether an injectable, bioactive, and degradable calcium sulfate/hydroxyapatite (CaS/HA) cement could increase the maximum pull-out force of pedicle screws in osteoporotic vertebrae. Herein, 17 osteoporotic thoracic and lumbar vertebrae were obtained from a single fresh-frozen human cadaver and instrumented with fenestrated pedicle screws. The right screw in each vertebra was augmented with CaS/HA cement and the un-augmented left side served as a paired control. The cement distribution, interdigitation ability, and cement leakage were evaluated using radiographs. Furthermore, pull-out testing was used to evaluate the immediate mechanical effect of CaS/HA augmentation on the pedicle screws. The CaS/HA cement presented good distribution and interdigitation ability without leakage into the spinal canal. Augmentation significantly enhanced the maximum pull-out force of the pedicle screw in which the augmented side was 39.0% higher than the pedicle-screw-alone side. Therefore, the novel biodegradable biphasic CaS/HA cement could be a promising material for pedicle screw augmentation in the osteoporotic spine.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Scoliosis diagnosis and treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus at Technische Universität Dresden, 01307 Dresden, Germany

Center for Translational Bone, Joint and Soft Tissue Research, Faculty of Medicine, University Hospital Carl Gustav Carus at Technische Universität Dresden, 01307 Dresden, Germany

Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, 22184 Lund, Sweden

Department of Radiology, University Hospital Carl Gustav Carus at Technische Universität Dresden, 01307 Dresden, Germany

Institute of Anatomy, University Hospital Carl Gustav Carus at Technische Universität Dresden, 01307 Dresden, Germany

References (41)

Show source-provided references
1. Krenzlin, H., Foelger, A., Mailänder, V., Blase, C., Brockmann, M., Düber, C., Ringel, F., and Keric, N. (2021). Novel Biodegradable Composite of Calcium Phosphate Cement and the Collagen I Mimetic P-15 for Pedicle Screw Augmentation in Osteoporotic Bone. Biomedicines, 9.10.3390/biomedicines9101392 ↗
2. Osteoporosis: A still increasing prevalence10.1016/j.bone.2005.11.024 ↗
3. Strategies of spinal fusion on osteoporotic spine10.3340/jkns.2011.49.6.317 ↗
4. Microstructural properties of trabecular bone autografts: Comparison of men and women with and without osteoporosis10.1007/s11657-018-0422-z ↗
5. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines10.1097/BRS.0b013e318205e3af ↗
6. Augmentation of fenestrated pedicle screws with cement in patients with osteoporotic spine10.4103/jcvjs.JCVJS_14_18 ↗
7. Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly10.1007/s00068-013-0310-6 ↗
8. Osteoporosis and the Management of Spinal Degenerative Disease (I)
9. Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: Current status10.1155/2014/748393 ↗
10. Screw-Related Complications after Instrumentation of the Osteoporotic Spine: A Systematic Literature Review with Meta-Analysis10.1177/2192568218818164 ↗
11. A novel injectable calcium phosphate-based nanocomposite for the augmentation of cannulated pedicle-screw fixation10.2147/IJN.S131962 ↗
12. A novel calcium phosphate-based nanocomposite for the augmentation of cement-injectable cannulated pedicle screws fixation: A cadaver and biomechanical study10.1016/j.jot.2019.08.001 ↗
13. Effects of prosthetic materials on the host immune response: Evaluation of polymethyl-methacrylate (PMMA), polyethylene (PE), and polystyrene (PS) particles10.1615/JLongTermEffMedImplants.v16.i6.20 ↗
14. Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength10.1016/S1529-9430(02)00207-3 ↗
15. The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection10.1097/BSD.0b013e3181dd7961 ↗
16. Pedicle screw augmentation in osteoporotic spine: Indications, limitations and technical aspects10.1007/s00068-016-0750-x ↗
17. A facile one-stage treatment of critical bone defects using a calcium sulfate/hydroxyapatite biomaterial providing spatiotemporal delivery of bone morphogenic protein-2 and zoledronic acid10.1126/sciadv.abc1779 ↗
18. Assessment of cellular viability on calcium sulphate/hydroxyapatite injectable scaffolds10.1177/2041731413509645 ↗
19. Osteotomy of distal radius fracture malunion using a fast remodeling bone substitute consisting of calcium sulphate and calcium phosphate10.1002/jbm.b.31524 ↗
20. Factors influencing the compressive strength of an injectable calcium sulfate-hydroxyapatite cement10.1023/A:1023254632704 ↗
21. Osteoporotic vertebral compression fractures augmentation by injectable partly resorbable ceramic bone substitute (Cerament™|SPINE SUPPORT): A prospective nonrandomized study10.1007/s00234-011-0940-5 ↗
22. Effectiveness of a bone substitute (CERAMENT™) as an alternative to PMMA in percutaneous vertebroplasty: 1-year follow-up on clinical outcome10.1007/s00586-012-2228-9 ↗
23. Augmenting a dynamic hip screw with a calcium sulfate/hydroxyapatite biomaterial10.1016/j.medengphy.2021.05.006 ↗
24. The effect of a biphasic injectable bone substitute on the interface strength in a rabbit knee prosthesis model10.1186/1749-799X-8-25 ↗
25. A New Augmentation Method for Improved Screw Fixation in Fragile Bone10.3389/fbioe.2022.816250 ↗
26. Li, D., Sun, C., Jiang, J., Lu, F., Xia, X., Wang, H., Zou, F., and Ma, X. (2022). A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws-analysis of Hounsfield units measurements based on computed tomography. BMC Musculoskelet. Disord., 23.10.1186/s12891-022-05074-6 ↗
27. Associations between the hounsfield unit values of different trajectories and bone mineral density of vertebrae: Cortical bone and traditional trajectories
28. Surgical strategies to improve fixation in the osteoporotic spine: The effects of tapping, cement augmentation, and screw trajectory10.1055/s-0033-1361588 ↗
29. A meta-analysis of the diagnostic accuracy of Hounsfield units on computed topography relative to dual-energy X-ray absorptiometry for the diagnosis of osteoporosis in the spine surgery population10.1016/j.spinee.2021.03.008 ↗
30. The effect of cement augmentation on pedicle screw fixation under various load cases: Results from a combined experimental, micro-CT, and micro-finite element analysis10.1302/2046-3758.1012.BJR-2020-0533.R1 ↗
31. Insufficient stability of pedicle screws in osteoporotic vertebrae: Biomechanical correlation of bone mineral density and pedicle screw fixation strength10.1007/s00586-017-5091-x ↗
32. Measurement Techniques and Utility of Hounsfield Unit Values for Assessment of Bone Quality Prior to Spinal Instrumentation: A Review of Current Literature10.1097/BRS.0000000000002813 ↗
33. Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae10.1302/2046-3758.59.2000580 ↗
34. The biomechanics of pedicle screw augmentation with cement10.1016/j.spinee.2015.03.016 ↗
35. Outcomes of the use of cement-augmented cannulated pedicle screws in lumbar spinal fusion10.1016/j.spinee.2021.05.005 ↗
36. Tissue reaction and material biodegradation of a calcium sulfate/apatite biphasic bone substitute in rat muscle10.1016/j.jot.2015.11.002 ↗
37. Long-Term Response to a Bioactive Biphasic Biomaterial in the Femoral Neck of Osteoporotic Rats10.1089/ten.tea.2020.0018 ↗
38. Calcium Sulphate/Hydroxyapatite Carrier for Bone Formation in the Femoral Neck of Osteoporotic Rats10.1089/ten.tea.2018.0075 ↗
39. A Biphasic Calcium Sulphate/Hydroxyapatite Carrier Containing Bone Morphogenic Protein-2 and Zoledronic Acid Generates Bone10.1038/srep26033 ↗
40. Biomodulation of an implant for enhanced bone-implant anchorage10.1016/j.actbio.2019.07.009 ↗
41. Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: Pullout versus fatigue testing10.1007/s00586-014-3476-7 ↗