journal article·2021-06-07Open access

Bioactivity of an Experimental Dental Implant with Anodized Surface

Maria Fernanda Lima Villaça-Carvalho, Juliani Caroline Ribeiro de Araújo, Juliana Mariano Beraldo, Renata Falchete do Prado, Mari Eli Leonelli de Moraes, Luiz Roberto Coutinho Manhães Junior, Eduardo Norberto Codaro, Heloisa Andrea Acciari, João Paulo Barros Machado, Natal Nerímio Regone, Anderson Oliveira Lobo, Fernanda Roberta Marciano, Luana Marotta Reis de Vasconcellos

Abstract

Background: Several studies proved that anodic oxidation improves osseointegration. This study aimed to optimize osseointegration through anodization in dental implants, obtaining anatase phase and controlled nanotopography. Methods: The division of the groups with 60 titanium implants was: control (CG); sandblasted (SG); anodized (AG): anodized pulsed current (duty cycle 30%, 30 V, 0.2 A and 1000 Hz). Before surgery, surface characterization was performed using Atomic Force Microscopy (AFM), Scanning Electron Microscopy (SEM), X-ray Dispersive Energy Spectroscopy (EDS) and Raman Spectroscopy. For in vivo tests, 10 New Zealand white rabbits received an implant from each group. The sacrifice period was 2 and 6 weeks (n = 5) and the specimens were subjected to computed microtomography (μCT) and reverse torque test. Results: AFM and SEM demonstrated a particular nanotopography on the surface in AG; the anatase phase was proved by Raman spectroscopy. In the μCT and in the reverse torque test, the AG group presented better results than the other groups. Conclusion: The chemical composition and structure of the TiO2 film were positively affected by the anodizing technique, intensifying the biological characteristics in osseointegration.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Periodontal Regeneration and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Bioscience and Oral Diagnosis, Institute of Science and Technology, UNESP—São Paulo State University São José dos Campos, São Paulo 12245-000, Brazil

Department of Chemistry and Energy, School of Engineering, Guaratinguetá Campus, UNESP—São Paulo State University, Guaratinguetá, São Paulo 12516-410, Brazil

Associated Laboratory of Sensors and Materials, National Institute for Space Research, INPE, São José dos Campos, São Paulo 12227-010, Brazil

Department of Aeronautic and Communication Engineering São João da Boa Vista Campus, UNESP—São Paulo State University, São João da Boa Vista, São Paulo 13876-750, Brazil

LIMAV—Interdisciplinary Laboratory for Advanced Materials, BioMatLab, UFPI—Federal University of Piaui, Teresina 64049-550, Brazil

Department of Physics, UFPI—Federal University of Piauí, Teresina 64049-550, Brazil

Funding

Fundação de Amparo à Pesquisa do Estado de São Paulo

References (30)

Show source-provided references
1. Cell adhesion and in vivo osseointegration of sandblasted/acid etched/anodized dental implants10.3390/ijms160510324 ↗
2. Controlled implant/soft tissue interaction by nanoscale surface modifications of 3D porous titanium implants10.1039/C5NR01237F ↗
3. Utilizing micro-computed tomography to evaluate bone structure surrounding dental implants: A comparison with histomorphometry10.1002/jbm.b.32938 ↗
4. Novel production method of porous surface Ti samples for biomedical application10.1007/s10856-011-4515-0 ↗
5. A comparative study of the influence of three pure titanium plates with different micro- and nanotopographic surfaces on preosteoblast behaviors10.1002/jbm.a.34612 ↗
6. Enhanced osteoblast functions on anodized titanium with nanotube-like structures10.1002/jbm.a.31551 ↗
7. Biophysical evaluation of cells on nanotubular surfaces: The effects of atomic ordering and chemistry
8. Ultra-structural evaluation of an anodic oxidated titanium dental implant10.4012/dmj.2014-121 ↗
9. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: The oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition10.1016/S0142-9612(01)00131-4 ↗
10. Nanopore formation on the surface oxide of commercially pure titanium grade 4 using a pulsed anodization method in sulfuric acid10.1007/s10856-013-4985-3 ↗
11. Surface characteristics and bioactivity of an anodized titanium surface10.5051/jpis.2013.43.4.198 ↗
12. Biological and Mechanical Effects of Micro Nanostructured Titanium Surface on an Osteoblastic Cell Line In vitro and Osteointegration In vivo10.1007/s12010-017-2444-1 ↗
13. Titanium-35niobium alloy as a potential material for biomedical implants: In vitro study10.1016/j.msec.2015.07.026 ↗
14. Characterization of passive films formed on titanium during anodic oxidation10.1016/j.electacta.2011.07.129 ↗
15. Selective formation of hydroxyapatite layers on titanium dioxide10.1134/S1070427214110032 ↗
16. Histomorphometric evaluation of titanium implants in osteoporotic rabbits10.1097/00008505-200009040-00005 ↗
17. Gehrke, S.A., Dedavid, B.A., Aramburú, J.S., Pérez-Díaz, L., Guirado, J.L., Canales, P.M., and De Aza, P.N. (2018). Effect of Different Morphology of Titanium Surface on the Bone Healing in Defects Filled Only with Blood Clot: A New Animal Study Design. Biomed. Res. Int., 4265474.10.1155/2018/4265474 ↗
18. Yeo, I.L. (2019). Modifications of Dental Implant Surfaces at the Micro- and Nano-Level for Enhanced Osseointegration. Materials, 13.10.3390/ma13010089 ↗
19. Surface thermal oxidation on titanium implants to enhance osteogenic activity and in vivo osseointegration10.1038/srep31769 ↗
20. Effects of hydrofluoric acid and anodised micro and micro/nano surface implants on early osseointegration in rats10.1016/j.bjoms.2011.12.008 ↗
21. In-vivo bone response to titanium screw implants anodized in sodium sulfate10.1590/S0102-86502014000600005 ↗
22. Assessment of anodized titanium implants bioactivity
23. Residual stresses and Raman shift relation in anatase TiO2 thin film10.1016/j.tsf.2009.02.141 ↗
24. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25 °C and 37 °C10.1016/j.corsci.2009.06.035 ↗
25. EIS characterisation of Ti anodic oxide porous films formed using modulated potential10.1016/j.surfcoat.2007.03.005 ↗
26. Correlation between microtomography and histomorphometry for assessment of implant osseointegration10.1111/j.1600-0501.2004.01083.x ↗
27. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation10.5624/isd.2015.45.1.7 ↗
28. Hydroxyapatite-electroplated cp-titanium implant and its bone integration potentiality: An in vivo study10.1097/ID.0b013e31805d7dc4 ↗
29. Influence of nanostructures on the biological properties of Ti implants after anodic oxidation10.1007/s10856-013-5064-5 ↗
30. Improved pre-osteoblast response and mechanical compatibility of ultrafine-grained Ti-13Nb-13Zr alloy10.1111/j.1600-0501.2010.02053.x ↗