In-Vitro Comparison of Fracture Strength of Endocrowns and Overlays in Endodontically Treated Teeth Manufactured with Monolithic Lithium Disilicate and Zirconia
Source abstract
Abstract
To evaluate the fracture strength and the failure mode of endodontically treated molars restored with monolithic lithium disilicate and zirconia endocrowns and overlays. A total of 48 extracted mandibular molars were endodontically treated, decoronated 2 mm above the cementoenamel junction and divided into four 12-specimen groups. Group ELD: lithium disilicate endocrowns. Group EZ: monolithic zirconia endocrowns. Group OLD: lithium disilicate overlays. Group OZ: monolithic zirconia overlays. Overlays did not extend in the pulp chamber and endocrowns extended in the pulp chamber 2 mm. After adhesive bonding of the restorations, the specimens were subjected to thermocycling (×5000 cycles) and then to fracture resistance testing at lateral static loading (1 mm/min) at a universal testing machine. The failure mode of the specimens was qualitatively evaluated. Differences in means were compared using with t-tests for independent samples or Mann–Whitney test (p < 0.05). Weibull distribution analysis was also performed. Group ELD showed significantly higher fracture strength than all other groups (p = 0.001), and the highest Weibull modulus. Conclusions: Lithium disilicate endocrowns exhibit higher fracture strength and are more reliable compared to the other types of restorations examined. Endocrowns had more catastrophic failures compared to overlays.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Operative Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
References (68)
Show source-provided references
1. Buonocore Memorial Lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition
2. Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars. Part I: Fracture resistance and fracture mode10.1016/S0022-3913(08)60006-2 ↗
3. Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars. Part II: Strain measurement and stress distribution10.1016/S0022-3913(08)60027-X ↗
4. Effect of restorative protocol on cuspal strain and residual stress in endodontically treated molars10.2341/14-178-L ↗
5. Patient-specific finite element analysis of fiber post and ferrule design10.1016/j.joen.2017.04.024 ↗
6. Coronal tooth structure in root-treated teeth prepared for complete and partial coverage restorations10.1111/j.1365-2842.2009.01952.x ↗
7. Single crowns versus conventional fillings for the restoration of root filled teeth
8. Crown vs. composite for post-retained restorations: A randomized clinical trial10.1016/j.jdent.2016.03.007 ↗
9. Current options concerning the endodontically-treated teeth restoration with the adhesive approach10.1590/1807-3107bor-2018.vol32.0074 ↗
10. Crown and post-free adhesive restorations for endodontically treated posterior teeth: From direct composite to endocrowns
11. Fracture resistance of weakened teeth restored with condensable resin with and without cusp coverage10.1590/S1678-77572009000300006 ↗
12. Endocrown restorations: A systematic review and meta-analysis10.1016/j.jdent.2016.07.005 ↗
13. Comparison of fracture strength of endocrowns and glass fiber post-retained conventional crowns10.2341/11-105-L ↗
14. Finite element analysis of adhesive endo-crowns of molars at different height levels of buccally applied load
15. 3D-Finite element analysis of molars restored with endocrowns and posts during masticatory sim-ulation10.1016/j.dental.2013.09.014 ↗
16. Biomechanical assessment of restored mandibular molar by endocrown in comparison to a glass fiber post-retained conventional crown: 3D Finite Element Analysis10.1111/jopr.12690 ↗
17. Frankenberger, R., Winter, J., Dudek, M.C., Naumann, M., Amend, A., Braun, A., Krämer, N., and Roggendorf, M.J. (2021). Post-fatigue fracture and marginal behavior of endodontically treated teeth: Partial crown vs. full crown vs. endocrown vs. fiber-reinforced resin composite. Materials, 14.10.3390/ma14247733 ↗
18. No post-no core approach to restore severely damaged posterior teeth: An up to 10-year retrospective study of documented endocrown cases10.1016/j.jdent.2017.04.009 ↗
19. Clinical performance of chairside CAD/CAM feldspathic ceramic posterior shoulder crowns and endocrowns up to 12 years
20. Endocrowns: A systematic review10.1016/j.prosdent.2019.04.009 ↗
21. Survival and success of endocrowns: A systematic review and meta-analysis
22. The effect of a fiber reinforced cavity configuration on load bearing capacity and failure mode of endodontically treated molars restored with CAD/CAM resin composite overlay restorations10.1016/j.jdent.2015.06.012 ↗
23. Fracture Strength of Endodontically Treated Teeth Restored with Composite Overlays with and without Glass-fiber Reinforcement
24. Fracture resistance and microleakage of endocrowns utilizing three CAD-CAM blocks10.2341/13-143-L ↗
25. Fracture strength, failure type and Weibull characteristics of lithium disilicate and multiphase resin composite endocrowns under axial and lateral forces10.1016/j.dental.2016.01.004 ↗
26. Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD/CAM materials10.1016/j.jdent.2017.02.007 ↗
27. Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness10.1016/j.jpor.2017.11.003 ↗
28. Mechanical failure of endocrowns manufactured with different ceramic materials: An In Vitro Biomechanical Study10.1111/jopr.12499 ↗
29. Fracture resistance and failure modes of lithium disilicate or composite endocrowns10.4103/njcp.njcp_175_17 ↗
30. Influence of the type of post and core on in vitro marginal continuity, fracture resistance, and fracture mode of lithia disilicate-based all-ceramic crowns10.1016/S0022-3913(08)60205-X ↗
31. Evaluation of failure risks in ceramic restorations for endodontically treated premolar with MOD preparation10.1016/j.dental.2010.10.026 ↗
32. Endocrowns clinical performance and patient satisfaction: A randomized clinical trial of three monolithic ceramic restorations10.1111/jopr.13414 ↗
33. Clinical research on restorations using CAD/CAM-fabricated monolithic zirconia endocrowns and post and core crowns after up to 5 years
34. Post-fatigue fracture resistance of premolar teeth restored with endocrowns: An in vitro investigation10.1016/j.jdent.2020.103426 ↗
35. Mechanical behavior of endocrowns fabricated with different CAD-CAM ceramic systems10.1016/j.prosdent.2019.11.008 ↗
36. Fracture resistance of maxillary premolars restored with different endocrown designs and materials after artificial ageing10.2186/jpr.JPR_D_20_00082 ↗
37. Effect of endocrown pulp chamber extension depth on molar fracture resistance10.2341/16-097-L ↗
38. The treatment of results for tensile bond strength testing10.1016/0300-5712(86)90019-9 ↗
39. Restoration of severely damaged endodontically treated premolars: The influence of the endo-core length on marginal integrity and fatigue resistance of lithium disilicate CAD-CAM ceramic endocrowns10.1016/j.jdent.2017.10.011 ↗
40. Effect of inlays, onlays and endocrown cavity design preparation on fracture resistance and fracture mode of endodontically treated teeth: An in vitro study10.1111/jopr.13294 ↗
41. Effect of different preparation designs and all ceramic materials on fracture strength of molar endocrowns
42. Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study10.1016/j.prosdent.2018.10.024 ↗
43. Preparation ferrule design effect on endocrown failure resistance10.1111/jopr.12671 ↗
44. Marginal adaptation and fracture strength of endocrowns manufactured with different restorative materials: SEM and mechanical evaluation10.1002/jemt.23586 ↗
45. Influence of remaining tooth structure and restorative material type on stress distribution in endodontically treated maxillary premolars: A finite element analysis10.1016/j.prosdent.2016.08.023 ↗
46. Biomechanical behavior of endocrown restorations with different CAD-CAM materials: A 3D finite element and in vitro analysis10.1016/j.prosdent.2020.03.009 ↗
47. Influence of translucence/opacity and shade in the flexural strength of lithium disilicate ceramics10.4103/0972-0707.164053 ↗
48. CAD-FEA modeling and analysis of different full crown monolithic restorations10.1016/j.dental.2018.06.024 ↗
49. Fracture strengths of endocrown restorations fabricated with different preparation depths and CAD/CAM materials10.4012/dmj.2017-035 ↗
50. Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients10.3109/00016359509005982 ↗
51. Bruxism and voluntary maximal bite force in young dentate adults
52. Maximum voluntary molar bite force in subjects with normal occlusion10.1093/ejo/cjq097 ↗
53. A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forces10.1016/0021-9290(88)90219-9 ↗
54. Application and validation of a three-dimensional mathematical model of the human masticatory system in vivo10.1016/0021-9290(92)90274-5 ↗
55. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure10.1177/00220345990780070801 ↗
56. Masticatory efficiency and bite force in individuals with normal occlusion10.1016/j.archoralbio.2014.05.005 ↗
57. Scaminaci Russo, D., Cinelli, F., Sarti, C., and Giachetti, L. (2019). Adhesion to Zirconia: A Systematic Review of Current Conditioning Methods and Bonding Materials. Dent. J., 7.10.3390/dj7030074 ↗
58. Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry
59. Thomas, R.M., Kelly, A., Tagiyeva, N., and Kanagasingam, S. (2020). Comparing endocrown restorations on permanent molars and premolars: A systematic review and meta-analysis. Br. Dent. J., 12.10.1038/s41415-020-2279-y ↗
60. Cerec 3D endocrowns—Two-year clinical examination of CAD/CAM crowns for restoring endodontically treated molars
61. The endocrown: A different type of all-ceramic reconstruction for molars
62. Thermal cycling for restorative materials: Does a standardized protocol exist in laboratory testing? A literature review10.1016/j.jmbbm.2013.09.013 ↗
63. Meta-analytical review of factors involved in dentin adherence10.1177/00220345010800070301 ↗
64. Meta-analytical review of parameters involved in dentin bonding10.1177/0022034511431251 ↗
65. Shear bond strength of composite resin cements to lithium disilicate ceramics10.1111/j.1365-2842.2004.01400.x ↗
66. Adhesive bonding of a lithium disilicate ceramic material with resin-based luting agents10.1111/j.1365-2842.2005.01464.x ↗
67. Influence of root embedment material and periodontal ligament simulation on fracture resistance tests10.1590/S1806-83242005000100003 ↗
68. Risk of onlay fracture during pre-cementation functional occlusal tapping10.1016/j.dental.2011.05.011 ↗