Show source-provided references
1. The International Thoracic Organ Transplant Registry of the International Society for Heart and Lung Transplantation: 37th Adult Heart Transplantation Report—2020; Focus on Deceased Donor Characteristics
10.1016/j.healun.2020.07.010 ↗5. A systematic review of cost-effectiveness analyses of left ventricular assist devices: Issues and challenges
10.1007/s40258-018-0439-x ↗12. A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: Shear stress, exposure time and hemolysis index
10.1115/1.4007092 ↗13. Thrombus formation patterns in the HeartMate II ventricular assist device: Clinical observations can be predicted by numerical simulations
10.1097/MAT.0000000000000034 ↗14. Numerical analysis of blood damage potential of the HeartMate II and HeartWare HVAD rotary blood pumps
10.1111/aor.12542 ↗15. A two-stage rotary blood pump design with potentially lower blood trauma: A computational study
10.5301/ijao.5000482 ↗16. Karimov, J.H., Fukamachi, K., and Starling, R.C. (2020). Computational fluid dynamics for mechanical circulatory support device development. Mechanical Support for Heart Failure, Springer.
10.1007/978-3-030-47809-4 ↗18. Long-term changes in kidney function after left ventricular assist device implant: An analysis of the STS Intermacs database
10.1016/j.healun.2019.01.206 ↗19. Hemolysis and free hemoglobin revisited: Exploring hemoglobin and hemin scavengers as a novel class of therapeutic proteins
10.1182/blood-2012-11-451229 ↗24. Strain-based blood damage estimation for computational design of ventricular assist devices
10.5301/ijao.5000484 ↗27. Hydrodynamic and hemolysis analysis on distance and clearance between impeller and diffuser of axial blood pump
10.1142/S0219519416500147 ↗28. Blood pump design variations and their influence on hydraulic performance and indicators of hemocompatibility
10.1007/s10439-017-1951-0 ↗30. Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance
10.1111/j.1525-1594.2005.29095.x ↗34. Optimization of axial pump characteristic dimensions and induced hemolysis for mechanical circulatory support devices
10.1097/MAT.0000000000000719 ↗37. Effect of blade curvature on the hemolytic and hydraulic characteristics of a centrifugal blood pump
10.1177/0391398818785558 ↗42. Advances in hemodynamic analysis in cardiovascular diseases Investigation of energetic characteristics of adult and pediatric Sputnik left ventricular assist devices during mock circulation support
10.1155/2019/4593174 ↗43. Estimation of shear stress-related blood trauma in heart valve prostheses—In vitro comparison of 25 aortic valves
10.1177/039139889001300507 ↗48. ASTM International F-1841-97(2013) (2013). Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps. Annual Book of ASTM Standards, vol. 13.01. Medical and Surgical Materials and Devices (I): E667–F2477, ASTM International.
49. ASTM International F-1830-97(2013) (2013). Standard Practice for Selection of Blood for in vitro Evaluation of Blood Pumps. Annual Book of ASTM Standards, vol. 13.01. Medical and Surgical Materials and Devices (I): E667–F2477, ASTM International.
52. Evaluation of in vitro hemolysis and platelet activation of a newly developed maglev LVAD and two clinically used LVADs with human blood
10.1111/aor.13471 ↗54. Kuchinka, J., Willems, C., Telyshev, D.V., and Groth, T. (2021). Control of blood coagulation by hemocompatible material surfaces—A review. Bioengineering, 8.
10.3390/bioengineering8120215 ↗55. Bird, R.B., Armstrong, R.C., and Hassager, O. (1987). Dynamics of Polymeric Liquids, Volume 1: Fluid Mechanics, Wiley.
56. Kim, S. (2002). A Study of Non-Newtonian Viscosity and Yield Stress of Blood in a Scanning Capillary-Tube Rheometer. [Ph.D. Thesis, Drexel University].
57. Determination of rheological properties of whole blood with a scanning capillary-tube rheometer using constitutive models
10.1007/s12206-009-0420-6 ↗58. MRI measurement of time-resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictions
10.1002/jmri.10243 ↗61. Numerical experiment for ultrasonic-measurement-integrated simulation of developed laminar pipe flow using axisymmetric model
10.1299/jbse.3.101 ↗62. Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI
10.1002/mrm.10025 ↗63. Feasibility of in vivo measurement of carotid wall shear rate using spiral Fourier velocity encoded MRI
10.1002/mrm.22325 ↗