Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties
Source abstract
Abstract
Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files allows the clinicians to produce the desirable tapered root canal form with a reduced tendency to canal transportation and instrument fracture. HyFlex CM instruments are new NiTi rotary instruments with shape memory produced by an innovative methodology (patent pending) that uses a complex heating and cooling treatment that controls the material’s memory. The aim of the present study was to compare the cleaning efficacy of two conventional (Mtwo, Revo-S) Ni-Ti rotary instruments with HyFlex CM. 30 single-rooted freshly extracted teeth were divided into three groups. Root canals were shaped with three NiTi instruments (Mtwo, Revo-S and HyFlex CM) using 5.25% NaOCl and 17% EDTA solutions. Specimens were fractured longitudinally and prepared for SEM analysis at standard magnification of 1000×. The presence/absence of debris smear layer and the presence/absence of smear layer at coronal, middle, and apical third of each canal were evaluated using a 5-step scale for scores. Numeric data were analyzed using Kruskall-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05. This study revealed significant differences among the various groups. Despite some minor differences, all instruments removed smear layer and debris produced during instrumentation. HyFlex CM seem to be not so effective in promoting cleanliness of root canal walls and in removing smear layer from dentine if compared to Mtwo and Revo-S.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Dental materials and restorations · Occupational health in dentistry
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Clinical-Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Piazzale Golgi 3, 27100 Pavia, Italy
Department of Brain and Behavioural Sciences—Section of Statistics, University of Pavia, Via Bassi 21, 27100 Pavia, Italy
References (28)
Show source-provided references
1. Torabinejad, M., and Walton, R.E. (2009). Endodontics: Principles and Practice, Saunders Elsevier. [4th ed.].
2. The effectiveness of four clinical irrigation methods on the removal of root canal debris
3. Efficacy of different irrigation methods and concentrations of root canal irrigation solutions on bacteria in the root canal10.1111/j.1600-9657.1992.tb00218.x ↗
4. Antimicrobial effect of six endodontic sealers: An in vitro evaluation10.1111/j.1600-9657.1999.tb00748.x ↗
5. Antimicrobial activity of endodontic sealers on enterococcus faecalis10.1097/00004770-200304000-00006 ↗
6. An in vitro evaluation of the particle flotation capability of various irrigating solutions
7. An evaluation of the action of different root canal irrigants on facoltative aerobic-anaerobic, obligate anaerobic, and microaerophilic bacteria10.1016/S0099-2399(06)81170-2 ↗
8. A comparison of 2.0% chlorhexidine gluconate and 5.25% sodium hypochlorite as antimicrobial endodontic irrigants10.1016/S0099-2399(06)80815-0 ↗
9. Antibacterial effects of endodontic irrigants on black-pigmented gram-negative anaerobes and facultative bacteria10.1016/S0099-2399(98)80023-X ↗
10. Microbiologic analysis of teeth with failed endodontic treatment and the outcome of conservative retreatment10.1016/S1079-2104(98)90404-8 ↗
11. In vitro antimicrobial efficacy of MTAD and sodium hypochlorite10.1097/00004770-200307000-00006 ↗
12. Influence of the NiTi rotary system on the debridement quality of the root canal space10.1016/j.tripleo.2009.05.012 ↗
13. Comparison of root canal preparation with two rotary NiTi instruments: ProFile 0.04 and GT Rotary10.1111/j.1365-2591.2007.01270.x ↗
14. A comparative evaluation of smear layer removal with ethylenediaminetetraacetic acid in different states: A SEM study10.4103/0970-9290.79967 ↗
15. Antimicrobical activity of varying concentrations of sodium hypochlorite on the endodontic microorganisms Actinomyces israelii, A. naeslundii, Candida albicans and Enterococcus faecalis10.1111/j.1365-2591.2004.00752.x ↗
16. In vitro evaluation of antimicrobial efficacy of endodontic irrigants10.5301/ijao.5000049 ↗
17. Reduction of intracanal bacteria using nickel-titanium rotary instrumentation and various medications10.1097/00004770-200012000-00022 ↗
18. SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments10.1111/j.1365-2591.2004.00887.x ↗
19. The effectiveness of different acid irrigating solutions in root canal cleaning after hand and rotary instrumentation10.1016/j.joen.2006.05.016 ↗
20. Scanning electron microscopic evaluation of debris and smear layer remaining following use of ProTaper and Hero Shaper instruments in combination with NaOCl and EDTA irrigation10.1016/j.tripleo.2008.04.032 ↗
21. Efficacy of bacterial removal from instrumented root canals in vitro related to instrumentation technique and size10.1067/moe.2002.126164 ↗
22. Comparison of two rotary systems in root canal preparation regarding disinfection10.1016/j.joen.2010.03.012 ↗
23. Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: An in vitro microbiological evaluation10.5301/ijao.5000160 ↗
24. Long-term evaluation of the influence of smear layer removal on the sealing ability of different sealers10.1016/S0099-2399(99)80010-7 ↗
25. An apical leakage study in the presence and absence of the smear layer10.1111/j.1365-2591.1994.tb00236.x ↗
26. Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel10.1016/j.joen.2011.05.023 ↗
27. An in vitro assessment of the physical propeties of novel Hyflex nickel-titanium rotary instruments10.1111/j.1365-2591.2012.02067.x ↗
28. Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: A comparative SEM investigation10.1016/S0099-2399(97)80410-4 ↗