journal article·2016-12-01Open access

Silica-Based and Borate-Based, Titania-Containing Bioactive Coatings Characterization: Critical Strain Energy Release Rate, Residual Stresses, Hardness, and Thermal Expansion

Omar Rodriguez, Ali Matinmanesh, Sunjeev Phull, Emil Schemitsch, Paul Zalzal, Owen Clarkin, Marcello Papini, Mark Towler

Abstract

Silica-based and borate-based glass series, with increasing amounts of TiO2 incorporated, are characterized in terms of their mechanical properties relevant to their use as metallic coating materials. It is observed that borate-based glasses exhibit CTE (Coefficient of Thermal Expansion) closer to the substrate’s (Ti6Al4V) CTE, translating into higher mode I critical strain energy release rates of glasses and compressive residual stresses and strains at the coating/substrate interface, outperforming the silica-based glasses counterparts. An increase in the content of TiO2 in the glasses results in an increase in the mode I critical strain energy release rate for both the bulk glass and for the coating/substrate system, proving that the addition of TiO2 to the glass structure enhances its toughness, while decreasing its bulk hardness. Borate-based glass BRT3, with 15 mol % TiO2 incorporated, exhibits superior properties overall compared to the other proposed glasses in this work, as well as 45S5 Bioglass® and Pyrex.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, ON M5B 2K3, Canada

St. Michael’s Hospital, Toronto, ON M5B 1W8, Canada

Department of Surgery, University of Western Ontario, London, ON N6A 4V2, Canada

Oakville Trafalgar Memorial Hospital, Oakville, ON L6J 3L7, Canada

Faculty of Health Sciences, Department of Surgery, McMaster University, Hamilton, ON L8S 4L8, Canada

School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin D09 W6Y4, Ireland

Department of Biomedical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia

Funding

Collaborative Health Research Project

References (59)

Show source-provided references
1. Perceptions and acceptance of osseointegration among individuals with lower limb amputations: A prospective survey study10.1097/JPO.0b013e3181bfafba ↗
2. Rehabilitation of the trans–femoral amputee with an osseointegrated prosthesis: The United Kingdom experience10.1080/03093640308726667 ↗
3. Osseointegrated titanium implants for limb prostheses attachments: Infectious complications10.1007/s11999-010-1370-0 ↗
4. Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses10.1016/j.biomaterials.2006.03.041 ↗
5. Chaudhari, A., Braem, A., Vleugels, J., Martens, J.A., Naert, I., Cardoso, M.V., and Duyck, J. (2011). Bone tissue response to porous and functionalized titanium and silica based coatings. PLoS ONE, 6.10.1371/journal.pone.0024186 ↗
6. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs10.1002/jbm.820250708 ↗
7. Bonding mechanisms at the interface of ceramic prosthetic materials10.1002/jbm.820050611 ↗
8. Glass coatings on stainless steels for high-temperature oxidation protection: Mechanisms10.1016/j.corsci.2014.01.033 ↗
9. Enamelled coatings produced with low-alkaline bioactive glasses10.1016/j.surfcoat.2014.03.025 ↗
10. In vitro behavior of silicate glass coatings on Ti6Al4V10.1016/S0142-9612(02)00109-6 ↗
11. Bioactive borate glass coatings for titanium alloys10.1007/s10856-008-3419-0 ↗
12. Status and future concerns of clinical and environmental aluminum toxicology10.1080/009841096161050 ↗
13. The antibacterial effects of zinc ion migration from zinc-based glass polyalkenoate cements10.1007/s10856-006-8930-6 ↗
14. Zinc and silver glass polyalkenoate cements: An evaluation of their antibacterial nature
15. The effect of ionic dissolution products of Ca–Sr–Na–Zn–Si bioactive glass on in vitro cytocompatibility10.1007/s10856-010-4139-9 ↗
16. Ion release from copper phosphate cement and influence on Streptococcus mutans growth in vitro: A comparative study10.1159/000073393 ↗
17. Bioactive glass coatings: A review10.1179/1743294410Y.0000000008 ↗
18. Welsch, G., Boyer, R., and Collings, E.W. (1993). Materials Properties Handbook: Titanium Alloys, ASM International.
19. Adhesion of bioactive glass coating to Ti6Al4V oral implant10.1016/S0142-9612(00)00027-2 ↗
20. Electrophoretic deposition of bioactive glass coating on 316L stainless steel and electrochemical behavior study10.1016/j.apsusc.2012.06.038 ↗
21. Electrophoretic deposition of mesoporous bioactive glass on glass-ceramic foam scaffolds for bone tissue engineering10.1007/s10856-014-5346-6 ↗
22. Waste derived glass ceramic composites prepared by low temperature sintering/sinter-crystallisation10.1179/1743676115Y.0000000044 ↗
23. Brow, R.K., and Watkins, R.D. (1987). Reactions and Bonding between Glasses and Titanium.
24. Reaction between titanium and B2O3 melt/glass
25. Osseointegration in skeletal reconstruction and rehabilitation: A review
26. Osseointegrated implants in the treatment of the edentulous jaw
27. Stress–corrosion cracking by indentation techniques of a glass coating on Ti6Al4V for biomedical applications10.1016/j.jeurceramsoc.2005.01.045 ↗
28. Bioactive glass engineered coatings for Ti6Al4V alloys: Influence of strontium substitution for calcium on sintering behaviour10.1016/j.jnoncrysol.2010.05.017 ↗
29. Fabrication and mechanical properties of PLLA/PCL/HA composites via a biomimetic, dip coating, and hot compression procedure10.1007/s10856-010-4051-3 ↗
30. Behavior of indentation cracks near free surfaces and interfaces10.1007/BF00047064 ↗
31. Bioactive glass coatings with hydroxyapatite and Bioglass® particles on Ti-based implants. 1. Processing10.1016/S0142-9612(99)00131-3 ↗
32. Bioactive glass coatings for orthopedic metallic implants10.1016/S0955-2219(03)00303-0 ↗
33. Elastic/plastic indentation damage in ceramics: The median/radial crack system10.1111/j.1151-2916.1980.tb10768.x ↗
34. A critical evaluation of indentation techniques for measuring fracture toughness: I, direct crack measurements10.1111/j.1151-2916.1981.tb10320.x ↗
35. Measurement of mechanical properties by ultra-low load indentation10.1016/S0921-5093(98)00724-2 ↗
36. Fett, T. (2002). Computation of the Crack Opening Displacements for Vickers Indentation, Forschungszentrum Karlsruhe (FZKA).
37. Residual stresses and stress intensity factors for vickers indentation cracks in glass derived from COD measurements10.1002/adem.200400121 ↗
38. Stresses and stress intensity factor from COD of Vickers indentation cracks10.1023/B:JMSC.0000017792.25386.1d ↗
39. New formula for indentation toughness in ceramics10.1007/BF01729352 ↗
40. Fracture surface energy of glass10.1111/j.1151-2916.1969.tb13350.x ↗
41. Cracking during nanoindentation and its use in the measurement of fracture toughness10.1557/PROC-356-663 ↗
42. Venkateshan, S.P. (2015). Mechanical Measurements, John Wiley & Sons.10.1002/9781119115571 ↗
43. Anderson, T.L. (2005). Fracture Mechanics: Fundamentals and Applications, CRC Press.10.1201/9781420058215 ↗
44. Structural Role of Zinc Oxide in Glasses in the System Na2O–ZnO–SiO210.1111/j.1151-2916.1970.tb12091.x ↗
45. Elber, W. (1974). Effects of shot-peening residual stresses on the fracture and crack-growth properties of D6AC steel. Fract. Toughness Slow Stable Crack.10.1520/STP38591S ↗
46. Flaw-Insensitive Ion-Exchanged Glass: I, Theoretical Aspects10.1111/j.1151-2916.2001.tb00922.x ↗
47. Residual stresses, strength and toughness of laminates with different layer thickness ratios10.1016/j.actamat.2006.06.008 ↗
48. Mixed mode cracking in layered materials10.1016/S0065-2156(08)70164-9 ↗
49. Chemical durability and mechanical properties of calcium phosphate glasses with the addition of Fe2O3, TiO2 and ZnO
50. Physicochemical studies of phosphate based P2O5–Na2O–CaO–TiO2 glasses for biomedical applications10.1016/j.jnoncrysol.2006.08.047 ↗
51. Scratch resistance of sodium borosilicate glass10.2109/jcersj.109.1270_511 ↗
52. Effect of phase separation on the fracture toughness of SiO2–B2O3–Na2O glass10.1007/BF02711236 ↗
53. Quantitative evaluation of the adhesion of bioactive glasses onto Ti6Al4V substrates10.1016/j.matdes.2016.02.086 ↗
54. Li, Y., Matinmanesh, A., Curran, D.J., Schemitsch, E.H., Zalzal, P., Papini, M., Wren, A.W., and Towler, M.R. (2016). Characterization and Fracture Property of Different Strontium-containing Borate-based Glass Coatings for Ti6Al4V Substrates. J. Non-Cryst. Solids, submitted.10.1016/j.jnoncrysol.2016.12.010 ↗
55. Characterization of silica-based and borate-based, titanium-containing bioactive glasses for coating metallic implants
56. (2011). ASTM Standard E228. Standard Test Method for Linear Thermal Expansion of Solid Materials With a Push-Rod Dilatometer, ASTM International.
57. Stress distribution in multiphase systems: I, composites with planar interfaces10.1111/j.1151-2916.1967.tb14992.x ↗
58. An experimental investigation of residual stresses in an epoxy–steel laminate10.1016/j.ijadhadh.2005.07.006 ↗
59. Novel bioactive materials with different mechanical properties10.1016/S0142-9612(03)00044-9 ↗